3 # Copyright (c) 2003 Intel Corporation
6 # Copyright (c) 2004-2006 The Trustees of Princeton University
11 from Exceptions import *
18 Contact PLC and get the attributes for this node. Also, parse in
19 options from the node model strong.
21 Also, update any node network settings at PLC, minus the ip address,
22 so, upload the mac (if node_id was in conf file), gateway, network,
23 broadcast, netmask, dns1/2, and the hostname/domainname.
25 Expect the following keys to be set:
26 BOOT_CD_VERSION A tuple of the current bootcd version
27 SKIP_HARDWARE_REQUIREMENT_CHECK Whether or not we should skip hardware
30 The following keys are set/updated:
31 WAS_NODE_ID_IN_CONF Set to 1 if the node id was in the conf file
32 WAS_NODE_KEY_IN_CONF Set to 1 if the node key was in the conf file
33 BOOT_STATE The current node boot state
34 NODE_MODEL The user specified model of this node
35 NODE_MODEL_OPTIONS The options extracted from the user specified
37 SKIP_HARDWARE_REQUIREMENT_CHECK Whether or not we should skip hardware
39 NODE_SESSION The session value returned from BootGetNodeDetails
40 INTERFACES The network interfaces associated with this node
41 INTERFACE_SETTINGS A dictionary of the values of the interface settings
43 Return 1 if able to contact PLC and get node info.
44 Raise a BootManagerException if anything fails.
47 log.write( "\n\nStep: Retrieving details of node from PLC.\n" )
49 # make sure we have the variables we need
51 BOOT_CD_VERSION= vars["BOOT_CD_VERSION"]
52 if BOOT_CD_VERSION == "":
53 raise ValueError, "BOOT_CD_VERSION"
55 SKIP_HARDWARE_REQUIREMENT_CHECK= vars["SKIP_HARDWARE_REQUIREMENT_CHECK"]
56 if SKIP_HARDWARE_REQUIREMENT_CHECK == "":
57 raise ValueError, "SKIP_HARDWARE_REQUIREMENT_CHECK"
59 INTERFACE_SETTINGS= vars["INTERFACE_SETTINGS"]
60 if INTERFACE_SETTINGS == "":
61 raise ValueError, "INTERFACE_SETTINGS"
63 WAS_NODE_ID_IN_CONF= vars["WAS_NODE_ID_IN_CONF"]
64 if WAS_NODE_ID_IN_CONF == "":
65 raise ValueError, "WAS_NODE_ID_IN_CONF"
67 WAS_NODE_KEY_IN_CONF= vars["WAS_NODE_KEY_IN_CONF"]
68 if WAS_NODE_KEY_IN_CONF == "":
69 raise ValueError, "WAS_NODE_KEY_IN_CONF"
72 raise BootManagerException, "Missing variable in vars: %s\n" % var
73 except ValueError, var:
74 raise BootManagerException, "Variable in vars, shouldn't be: %s\n" % var
76 node_details= BootAPI.call_api_function( vars, "GetNodes",
78 ['boot_state', 'nodegroup_ids', 'interface_ids', 'model', 'site_id']))[0]
80 vars['BOOT_STATE']= node_details['boot_state']
81 vars['NODE_MODEL']= string.strip(node_details['model'])
82 vars['SITE_ID'] = node_details['site_id']
83 log.write( "Successfully retrieved node record.\n" )
84 log.write( "Current boot state: %s\n" % vars['BOOT_STATE'] )
85 log.write( "Node make/model: %s\n" % vars['NODE_MODEL'] )
87 # parse in the model options from the node_model string
88 model= vars['NODE_MODEL']
89 options= ModelOptions.Get(model)
90 vars['NODE_MODEL_OPTIONS']=options
92 # Check if we should skip hardware requirement check
93 if options & ModelOptions.MINHW:
94 vars['SKIP_HARDWARE_REQUIREMENT_CHECK']=1
95 log.write( "node model indicates override to hardware requirements.\n" )
97 # this contains all the node networks, for now, we are only concerned
98 # in the primary network
99 interfaces= BootAPI.call_api_function( vars, "GetInterfaces", (node_details['interface_ids'],))
101 for network in interfaces:
102 if network['is_primary'] == 1:
103 log.write( "Primary network as returned from PLC: %s\n" % str(network) )
108 raise BootManagerException, "Node did not have a primary network."
110 vars['INTERFACES']= interfaces