-import reboot
-
-import soltesz
-import plc
-import comon
-import threadpool
-import syncplcdb
-
-def pcu_name(pcu):
- if pcu['hostname'] is not None and pcu['hostname'] is not "":
- return pcu['hostname']
- elif pcu['ip'] is not None and pcu['ip'] is not "":
- return pcu['ip']
- else:
- return None
-
-def nmap_portstatus(status):
- ps = {}
- l_nmap = status.split()
- ports = l_nmap[4:]
-
- continue_probe = False
- for port in ports:
- results = port.split('/')
- ps[results[0]] = results[1]
- if results[1] == "open":
- continue_probe = True
- return (ps, continue_probe)
-
-def collectPingAndSSH(pcuname, cohash):
-
- continue_probe = True
- values = {}
- ### GET PCU ######################
- try:
- b_except = False
- plc_lock.acquire()
-
- try:
- l_pcu = plc.GetPCUs({'pcu_id' : pcuname})
-
- if len(l_pcu) > 0:
- node_ids = l_pcu[0]['node_ids']
- l_node = plc.getNodes(node_ids, ['hostname', 'last_contact', 'node_id'])
- site_id = l_pcu[0]['site_id']
-
- values['pcu_id'] = l_pcu[0]['pcu_id']
-
- if len(l_node) > 0:
- values['nodenames'] = [node['hostname'] for node in l_node]
- # NOTE: this is for a dry run later. It doesn't matter which node.
- values['node_id'] = l_node[0]['node_id']
-
- if len(l_pcu) > 0:
- values.update(l_pcu[0])
- else:
- continue_probe = False
-
- except:
- b_except = True
- import traceback
- traceback.print_exc()
-
- continue_probe = False
-
- plc_lock.release()
- if b_except: return (None, None)
-
- if values['hostname'] is not None:
- values['hostname'] = values['hostname'].strip()
-
- if values['ip'] is not None:
- values['ip'] = values['ip'].strip()
-
- #### COMPLETE ENTRY #######################
-
- values['complete_entry'] = []
- if values['protocol'] is None or values['protocol'] is "":
- values['complete_entry'] += ["protocol"]
- if values['model'] is None or values['model'] is "":
- values['complete_entry'] += ["model"]
- # Cannot continue due to this condition
- continue_probe = False
-
- if values['password'] is None or values['password'] is "":
- values['complete_entry'] += ["password"]
- # Cannot continue due to this condition
- continue_probe = False
-
- if len(values['complete_entry']) > 0:
- continue_probe = False
-
- if values['hostname'] is None or values['hostname'] is "":
- values['complete_entry'] += ["hostname"]
- if values['ip'] is None or values['ip'] is "":
- values['complete_entry'] += ["ip"]
-
- # If there are no nodes associated with this PCU, then we cannot continue.
- if len(values['node_ids']) == 0:
- continue_probe = False
- values['complete_entry'] += ['NoNodeIds']
-
- #### DNS and IP MATCH #######################
- if values['hostname'] is not None and values['hostname'] is not "" and \
- values['ip'] is not None and values['ip'] is not "":
- #print "Calling socket.gethostbyname(%s)" % values['hostname']
- try:
- ipaddr = socket.gethostbyname(values['hostname'])
- if ipaddr == values['ip']:
- values['dnsmatch'] = "DNS-OK"
- else:
- values['dnsmatch'] = "DNS-MISMATCH"
- continue_probe = False
-
- except Exception, err:
- values['dnsmatch'] = "DNS-NOENTRY"
- values['hostname'] = values['ip']
- #print err
- else:
- if values['ip'] is not None and values['ip'] is not "":
- values['dnsmatch'] = "NOHOSTNAME"
- values['hostname'] = values['ip']
- else:
- values['dnsmatch'] = "NO-DNS-OR-IP"
- values['hostname'] = "No_entry_in_DB"
- continue_probe = False
-
- #### RUN NMAP ###############################
- if continue_probe:
- nmap = soltesz.CMD()
- (oval,eval) = nmap.run_noexcept("nmap -oG - -p22,23,80,443,16992 %s | grep Host:" % pcu_name(values))
- # NOTE: an empty / error value for oval, will still work.
- (values['portstatus'], continue_probe) = nmap_portstatus(oval)
-
- ###### DRY RUN ############################
- node_ids = values['node_ids']
- ports = values['ports']
- nid2port = {}
- i = 0
-
- for id in node_ids:
- nid2port[id] = ports[i]
- i += 1
-
- # ####
- # TODO: check port status above for whether or not to try...
- # ####
- # DataProbe iPal (many sites)
- if continue_probe and values['model'].find("Dataprobe IP-41x/IP-81x") >= 0:
- if values['portstatus']['23'] == "open":
- rb_ret = reboot.ipal_reboot(pcu_name(values),
- values['password'],
- nid2port[values['node_id']],
- True)
- else:
- rb_ret = "Unsupported_Port"
-
-
- # APC Masterswitch (Berkeley)
- elif continue_probe and values['model'].find("APC AP79xx/Masterswitch") >= 0:
- if values['portstatus']['22'] == "open" or \
- values['portstatus']['23'] == "open":
- rb_ret = reboot.apc_reboot(pcu_name(values),
- values['username'],
- values['password'],
- nid2port[values['node_id']],
- values['portstatus'],
- True)
- else:
- rb_ret = "Unsupported_Port"
- # BayTech DS4-RPC
- elif continue_probe and values['model'].find("Baytech DS4-RPC") >= 0:
- if values['portstatus']['22'] == "open":
- rb_ret = reboot.baytech_reboot(pcu_name(values),
- values['username'],
- values['password'],
- nid2port[values['node_id']],
- True)
- else:
- rb_ret = "Unsupported_Port"
-
-
- # iLO
- elif continue_probe and values['model'].find("HP iLO") >= 0:
- if values['portstatus']['22'] == "open":
- rb_ret = reboot.ilo_reboot(pcu_name(values),
- values['username'],
- values['password'],
- True)
- else:
- rb_ret = "Unsupported_Port"
-
- # DRAC ssh
- elif continue_probe and values['model'].find("Dell RAC") >= 0:
- if values['portstatus']['22'] == "open":
- rb_ret = reboot.drac_reboot(pcu_name(values),
- values['username'],
- values['password'],
- True)
- else:
- rb_ret = "Unsupported_Port"
-
-
- # BlackBox PSExxx-xx (e.g. PSE505-FR)
- elif continue_probe and \
- (values['model'].find("BlackBox PS5xx") >= 0 or
- values['model'].find("ePowerSwitch 1/4/8x") >=0 ):
- if values['portstatus']['80'] == "open":
- rb_ret = reboot.bbpse_reboot(pcu_name(values),
- values['username'],
- values['password'],
- nid2port[values['node_id']],
- 80,
- True)
- else:
- rb_ret = "Unsupported_PCU"
-
- # x10toggle
- elif continue_probe and values['protocol'] == "ssh" and \
- values['model'] == "x10toggle":
- rb_ret = reboot.x10toggle_reboot(pcu_name(values),
- values['username'],
- values['password'],
- nid2port[values['node_id']],
- True)
- # ????
- elif continue_probe and values['protocol'] == "racadm" and \
- values['model'] == "RAC":
- rb_ret = reboot.racadm_reboot(pcu_name(values),
- values['username'],
- values['password'],
- nid2port[values['node_id']],
- True)
- elif continue_probe:
- rb_ret = "Unsupported_PCU"
-
- elif continue_probe == False:
- if 'portstatus' in values:
- rb_ret = "NetDown"
- else:
- rb_ret = "Not_Run"
- else:
- rb_ret = -1
-
- values['reboot'] = rb_ret
-
- ### GET PLC SITE ######################
- b_except = False
- plc_lock.acquire()
-
- try:
- d_site = plc.getSites({'site_id': site_id},
- ['max_slices', 'slice_ids', 'node_ids', 'login_base'])
- except:
- b_except = True
- import traceback
- traceback.print_exc()
-
- plc_lock.release()
- if b_except: return (None, None)
-
- if d_site and len(d_site) > 0:
- max_slices = d_site[0]['max_slices']
- num_slices = len(d_site[0]['slice_ids'])
- num_nodes = len(d_site[0]['node_ids'])
- loginbase = d_site[0]['login_base']
- values['plcsite'] = {'num_nodes' : num_nodes,
- 'max_slices' : max_slices,
- 'num_slices' : num_slices,
- 'login_base' : loginbase,
- 'status' : 'SUCCESS'}
- else:
- values['plcsite'] = {'status' : "GS_FAILED"}
- except:
- print "____________________________________"
- print values
- print "____________________________________"
- import traceback
- traceback.print_exc()
-
- return (pcuname, values)
-
-def recordPingAndSSH(request, result):
- global externalState
- global count
- (nodename, values) = result
-
- if values is not None:
- global_round = externalState['round']
- pcu_id = "id_%s" % nodename
- externalState['nodes'][pcu_id]['values'] = values
- externalState['nodes'][pcu_id]['round'] = global_round
-
- count += 1
- print "%d %s %s" % (count, nodename, externalState['nodes'][pcu_id]['values'])
- soltesz.dbDump(config.dbname, externalState)
-