Use the right variable.
[nodemanager.git] / NodeManager.spec
index eb074f0..3feb94b 100644 (file)
@@ -3,9 +3,11 @@
 #
 %define url $URL$
 
+%define slicefamily %{pldistro}-%{distroname}-%{_arch}
+
 %define name NodeManager
 %define version 1.7
-%define taglevel 1
+%define taglevel 18
 
 %define release %{taglevel}%{?pldistro:.%{pldistro}}%{?date:.%{date}}
 
@@ -27,7 +29,7 @@ URL: %(echo %{url} | cut -d ' ' -f 2)
 Obsoletes: sidewinder, sidewinder-common
 
 # vuseradd, vuserdel
-Requires: vserver-reference
+Requires: vserver-%{slicefamily}
 Requires: util-vserver >= 0.30.208-17
 
 # vserver.py
@@ -96,6 +98,83 @@ rm -rf $RPM_BUILD_ROOT
 %{_sysconfdir}/logrotate.d/nm
 
 %changelog
+* Fri Jun 27 2008 Faiyaz Ahmed <faiyaza@cs.princeton.edu> - NodeManager-1.7-18
+- Log disk init AFTER acquiring disk semaphore.
+
+* Wed Jun 25 2008 Thierry Parmentelat <thierry.parmentelat@sophia.inria.fr> - NodeManager-1.7-17
+- unconditionnally passes node_id and slicefamily to conf_file scripts
+- correctly set personality a sliver creation time (not yet used by util-vserver-pl though)
+
+* Thu Jun 19 2008 Stephen Soltesz <soltesz@cs.princeton.edu> - NodeManager-1.7-16
+- 
+- enables a vsys slice attribute to end with 'a', 'c', or 'l' characters without
+- NM going bonkers.
+- 
+
+* Wed Jun 18 2008 Stephen Soltesz <soltesz@cs.princeton.edu> - NodeManager-1.7-15
+- 
+- enable restart if vsys.conf changes also.
+- 
+
+* Wed Jun 18 2008 Stephen Soltesz <soltesz@cs.princeton.edu> - NodeManager-1.7-14
+- 
+- the _restart flag for vsys was getting lost when looking across multiple
+- vservers.  adding the 'or' should preserve any 'True' returns from
+- createVsysDir()
+- 
+
+* Tue Jun 17 2008 Faiyaz Ahmed <faiyaza@cs.princeton.edu> - NodeManager-1.7-13
+- 
+- Time out curl when no response for 90 seconds.
+- 
+
+* Fri Jun 13 2008 Stephen Soltesz <soltesz@cs.princeton.edu> - NodeManager-1.7-12
+- Patch designed to work around the vsys-fail-to-restart problem with
+- non-existent directories, and the vuseradd-fail-to-work on directories that
+- do exist.  
+- 
+- This patch will work in conjunction with the new vsys patch.
+- 
+
+* Wed May 14 2008 Thierry Parmentelat <thierry.parmentelat@sophia.inria.fr> - NodeManager-1.7-10
+- fixed doc build by locating locally installed DTDs at build-time
+
+* Fri May 09 2008 Faiyaz Ahmed <faiyaza@cs.princeton.edu> - NodeManager-1.7-9
+- * Reverted vserver start to forking before VServer.start to avoid defunct procs.* House keeping in various places.
+
+* Fri May 09 2008 Thierry Parmentelat <thierry.parmentelat@sophia.inria.fr> - NodeManager-1.7-8
+- merge changes for myplc-docs from trunk
+
+* Wed Apr 16 2008 Faiyaz Ahmed <faiyaza@cs.princeton.edu> - NodeManager-1.7-7
+- 
+- Set vcVHI_CONTEXT as slice_id for fprobe-ulog to mark packets with.
+- 
+
+* Wed Apr 09 2008 Faiyaz Ahmed <faiyaza@cs.princeton.edu> - NodeManager-1.7-5 NodeManager-1.7-6
+- 
+- * Codemux will use PLC_API_HOST when PLC_PLANETFLOW_HOST isn't defined.
+- 
+
+* Fri Apr 04 2008 Faiyaz Ahmed <faiyaza@cs.princeton.edu> - NodeManager-1.7-4 NodeManager-1.7-5
+- * vdu limitting when NM restarts and slices are re-init'ed
+- * CoDemux config parser update.  Now tolerates spaces.
+
+* Wed Apr 02 2008 Faiyaz Ahmed <faiyaza@cs.prineton.edu - NodeManager-1.7.4
+- Codemux supports multiple hosts mapping to single slice
+- Fixed bug in delegation support where tickets delivered weren't
+  being passed to sm.deliver_ticket().
+* Fri Mar 28 2008 Faiyaz Ahmed <faiyaza@cs.prineton.edu - NodeManager-1.7.3
+- Codemux now configured via slice attribute (host,port)
+- Support for multiple vserver reference images (including different archs)
+- Mom BW emails are sent to list defined by MyPLC's config
+- Sirius BW loans honored correctly.  Fixed.
+- BW totals preserved for dynamic slices so as not to game the system.
+* Thu Feb 14 2008 Faiyaz Ahmed <faiyaza@cs.princeton.edu> - NodeManager-1.7-1 NodeManager-1.7-2
+- Configures vsys via vsys slice attribute {name: vsys, value: script}
+- CPU reservations are now calculated via percentages instead of shares
+- BW totals preserved for dynamic slices
+- Closes bug where node cap sets off bw slice alarms for all slices.
+
 * Wed Oct 03 2007 Faiyaz Ahmed <faiyaza@cs.princeton.edu> .
 - Switched to SVN.