from subprocess import PIPE, Popen
import ssh.pxssh as pxssh
import ssh.pexpect as pexpect
-
-plc_lock = threading.Lock()
+import socket
# Use our versions of telnetlib and pyssh
sys.path.insert(0, os.path.dirname(sys.argv[0]))
self.close()
return 0
-def ipal_reboot(ip, password, port, dryrun):
- global verbose
- global plc_lock
- telnet = None
-
- try:
- #plc_lock.acquire()
- #print "lock acquired"
-
- #try:
- #telnet = telnetlib.Telnet(ip) # , timeout=TELNET_TIMEOUT)
- telnet = telnetlib.Telnet(ip, timeout=TELNET_TIMEOUT)
- #except:
- # import traceback
- # traceback.print_exc()
-
-
- telnet.set_debuglevel(verbose)
-
- # XXX Some iPals require you to hit Enter a few times first
- telnet_answer(telnet, "Password >", "\r\n\r\n")
-
- # Login
- telnet_answer(telnet, "Password >", password)
-
- # XXX Some iPals require you to hit Enter a few times first
- telnet.write("\r\n\r\n")
-
- # P# - Pulse relay
- if not dryrun:
- telnet_answer(telnet, "Enter >", "P%d" % port)
-
- telnet.read_until("Enter >", TELNET_TIMEOUT)
-
- # Close
- telnet.close()
-
- #print "lock released"
- #plc_lock.release()
- return 0
-
- except EOFError, err:
- if verbose:
- logger.debug("ipal_reboot: EOF")
- logger.debug(err)
- telnet.close()
- import traceback
- traceback.print_exc()
- #print "lock released"
- #plc_lock.release()
- return errno.ECONNRESET
- except socket.error, err:
- logger.debug("ipal_reboot: Socket Error")
- logger.debug(err)
- import traceback
- traceback.print_exc()
-
- return errno.ETIMEDOUT
-
- except Exception, err:
- if verbose:
- logger.debug("ipal_reboot: Exception")
- logger.debug(err)
- if telnet:
- telnet.close()
- import traceback
- traceback.print_exc()
- #print "lock released"
- #plc_lock.release()
- return "ipal error"
-
class APCEurope(PCUControl):
def run(self, node_port, dryrun):
self.open(self.host, self.username)
cmd = "cmdhttps/locfg.pl -s %s -f %s -u %s -p %s" % (
self.host, "iloxml/Reset_Server.xml",
self.username, self.password)
+ print cmd
p_ilo = Popen(cmd, stdin=PIPE, stdout=PIPE, shell=True)
cmd2 = "grep 'MESSAGE' | grep -v 'No error'"
p_grep = Popen(cmd2, stdin=p_ilo.stdout, stdout=PIPE, stderr=PIPE)
sout, serr = p_grep.communicate()
- p_ilo.wait()
- p_grep.wait()
+ try: p_ilo.wait()
+ except:
+ print "p_ilo wait failed."
+ pass
+ try: p_grep.wait()
+ except:
+ print "p_grep wait failed."
+ pass
if sout.strip() != "":
print "sout: %s" % sout.strip()
out += "; output follows:\n" + data
raise Exception, out
-def racadm_reboot(ip, username, password, port, dryrun):
+def racadm_reboot(host, username, password, port, dryrun):
global verbose
+ ip = socket.gethostbyname(host)
try:
cmd = "/usr/sbin/racadm"
os.stat(cmd)
ret = reboot_test(nodename, values, continue_probe, verbose, dryrun)
if ret != 0:
+ print ret
return False
else:
return True
apc = APCBrazil(values, verbose, ['22', '23'])
rb_ret = apc.reboot(values[nodename], dryrun)
- elif values['pcu_id'] in [1221]:
+ elif values['pcu_id'] in [1221,1225]:
apc = APCBerlin(values, verbose, ['22', '23'])
rb_ret = apc.reboot(values[nodename], dryrun)
- elif values['pcu_id'] in [1173,1221,1220,1225]:
+ elif values['pcu_id'] in [1173,1221,1220]:
apc = APCFolsom(values, verbose, ['22', '23'])
rb_ret = apc.reboot(values[nodename], dryrun)
# BayTech DS4-RPC
elif continue_probe and values['model'].find("Baytech DS4-RPC") >= 0:
- if values['pcu_id'] in [1052,1209,1002,1008,1041,1013,1022]:
+ if values['pcu_id'] in [1237,1052,1209,1002,1008,1041,1013,1022]:
# These require a 'ctrl-c' to be sent...
baytech = BayTechCtrlC(values, verbose, ['22', '23'])
rb_ret = baytech.reboot(values[nodename], dryrun)
# pcu[nodename],
# dryrun)
-# Returns true if rebooted via PCU
-def reboot_old(nodename, dryrun):
- pcu = plc.getpcu(nodename)
- if not pcu:
- plc.nodePOD(nodename)
- return False
- # Try the PCU first
- logger.debug("Trying PCU %s %s" % (pcu['hostname'], pcu['model']))
-
- # APC Masterswitch (Berkeley)
- if pcu['model'] == "APC Masterswitch":
- err = apc_reboot(pcu['ip'], pcu['username'],pcu['password'],
- pcu[nodename], pcu['protocol'], dryrun)
-
- # DataProbe iPal (many sites)
- elif pcu['protocol'] == "telnet" and pcu['model'].find("IP-4") >= 0:
- err = ipal_reboot(pcu['ip'],pcu['password'], pcu[nodename], dryrun)
-
- # BayTech DS4-RPC
- elif pcu['protocol'] == "ssh" and \
- (pcu['model'].find("Baytech") >= 0 or pcu['model'].find("DS4") >= 0):
- err = baytech_reboot(pcu['ip'], pcu['username'],pcu['password'], pcu[nodename], dryrun)
-
- # BlackBox PSExxx-xx (e.g. PSE505-FR)
- elif pcu['protocol'] == "http" and (pcu['model'] == "bbpse"):
- err = bbpse_reboot(pcu['ip'], pcu['username'], pcu['password'], pcu[nodename],80, dryrun)
-
- # x10toggle
- elif pcu['protocol'] == "ssh" and (pcu['model'] == "x10toggle"):
- err = x10toggle_reboot(pcu['ip'], pcu['username'],pcu['password'], pcu[nodename], dryrun)
-
- #
- elif pcu['protocol'] == "racadm" and (pcu['model'] == "RAC"):
- err = racadm_reboot(pcu['ip'], pcu['username'],pcu['password'], pcu_[nodename], dryrun)
-
- # Unknown or unsupported
- else:
- err = errno.EPROTONOSUPPORT
- return False
- return True
-
-
def main():
logger.setLevel(logging.DEBUG)
ch = logging.StreamHandler()
logger.addHandler(ch)
try:
- print "Rebooting %s" % sys.argv[1]
- reboot_policy(sys.argv[1], True, False)
+ for node in sys.argv[1:]:
+ print "Rebooting %s" % node
+ if reboot_policy(node, True, False):
+ print "success"
+ else:
+ print "failed"
except Exception, err:
print err