import urllib2
import threading, popen2
import array, struct
-from socket import *
+#from socket import *
+import socket
import plc
+plc_lock = threading.Lock()
+
# Use our versions of telnetlib and pyssh
sys.path.insert(0, os.path.dirname(sys.argv[0]))
import telnetlib
import pyssh
# Timeouts in seconds
-TELNET_TIMEOUT = 20
+TELNET_TIMEOUT = 30
# Event class ID from pcu events
#NODE_POWER_CONTROL = 3
import logging
logger = logging.getLogger("monitor")
verbose = 1
-dryrun = 0;
+#dryrun = 0;
+
+class ExceptionNotFound(Exception): pass
+class ExceptionPassword(Exception): pass
+class ExceptionTimeout(Exception): pass
+class ExceptionPrompt(Exception): pass
+class ExceptionPort(Exception): pass
def telnet_answer(telnet, expected, buffer):
global verbose
output = telnet.read_until(expected, TELNET_TIMEOUT)
- if verbose:
- logger.debug(output)
+ #if verbose:
+ # logger.debug(output)
if output.find(expected) == -1:
- raise Exception, "'%s' not found" % expected
+ raise ExceptionNotFound, "'%s' not found" % expected
else:
telnet.write(buffer + "\r\n")
-def ipal_reboot(ip, password, port):
- global dryrun, verbose
+# PCU has model, host, preferred-port, user, passwd,
+
+class PCUExpect:
+ def __init__(self, protocol, verbose, dryrun):
+ self.verbose = verbose
+ self.protocol = protocol
+ self.dryrun = dryrun
+
+ def telnet_answer(telnet, expected, buffer):
+ global verbose
+
+ output = telnet.read_until(expected, TELNET_TIMEOUT)
+ #if verbose:
+ # logger.debug(output)
+ if output.find(expected) == -1:
+ raise ExceptionNotFound, "'%s' not found" % expected
+ else:
+ telnet.write(buffer + "\r\n")
+
+ def _run(self, host, user, passwd, node_port, protocols):
+ self.run()
+
+ def run(self):
+ pass
+
+
+
+def ipal_reboot(ip, password, port, dryrun):
+ global verbose
+ global plc_lock
+
telnet = None
try:
+ #plc_lock.acquire()
+ #print "lock acquired"
+
+ #try:
+ #telnet = telnetlib.Telnet(ip) # , timeout=TELNET_TIMEOUT)
telnet = telnetlib.Telnet(ip, timeout=TELNET_TIMEOUT)
+ #except:
+ # import traceback
+ # traceback.print_exc()
+
+
telnet.set_debuglevel(verbose)
# XXX Some iPals require you to hit Enter a few times first
# Login
telnet_answer(telnet, "Password >", password)
+ # XXX Some iPals require you to hit Enter a few times first
+ telnet.write("\r\n\r\n")
+
# P# - Pulse relay
if not dryrun:
telnet_answer(telnet, "Enter >", "P%d" % port)
# Close
telnet.close()
+
+ #print "lock released"
+ #plc_lock.release()
return 0
except EOFError, err:
if verbose:
+ logger.debug("ipal_reboot: EOF")
logger.debug(err)
telnet.close()
+ import traceback
+ traceback.print_exc()
+ #print "lock released"
+ #plc_lock.release()
return errno.ECONNRESET
+ except socket.error, err:
+ logger.debug("ipal_reboot: Socket Error")
+ logger.debug(err)
+ import traceback
+ traceback.print_exc()
+
+ return errno.ETIMEDOUT
+
except Exception, err:
if verbose:
+ logger.debug("ipal_reboot: Exception")
logger.debug(err)
if telnet:
telnet.close()
- return errno.ETIMEDOUT
+ import traceback
+ traceback.print_exc()
+ #print "lock released"
+ #plc_lock.release()
+ return "ipal error"
-def apc_reboot(ip, username, password, port):
- global dryrun, verbose
+def apc_reboot(ip, username, password, port, protocol, dryrun):
+ global verbose
+
+ transport = None
+
+ # TODO: I may need to differentiate between different models of APC
+ # hardware...
+ # for instance, the original code didn't work for:
+ # planetdev03.fm.intel.com
+ # American Power Conversion
+ # Network Management Card AOS v3.3.0
+ # (c) Copyright 2005 All Rights Reserved
+ # Rack PDU APP v3.3.1
- telnet = None
try:
- telnet = telnetlib.Telnet(ip, timeout=TELNET_TIMEOUT)
- telnet.set_debuglevel(verbose)
+ #if "ssh" in protocol:
+ if "22" in protocol and protocol['22'] == "open":
+ transport = pyssh.Ssh(username, ip)
+ transport.open()
+ # Login
+ telnet_answer(transport, "password:", password)
+ #elif "telnet" in protocol:
+ elif "23" in protocol and protocol['23'] == "open":
+ transport = telnetlib.Telnet(ip, timeout=TELNET_TIMEOUT)
+ #transport = telnetlib.Telnet(ip)
+ transport.set_debuglevel(verbose)
+ # Login
+ telnet_answer(transport, "User Name", username)
+ telnet_answer(transport, "Password", password)
+ else:
+ logger.debug("Unknown protocol %s" %protocol)
+ raise "Closed protocol ports!"
- # Login
- telnet_answer(telnet, "User Name", username)
- telnet_answer(telnet, "Password", password)
# 1- Device Manager
# 2- Network
# 4- Logout
# 1- Device Manager
- telnet_answer(telnet, "\r\n> ", "1")
+ telnet_answer(transport, "\r\n> ", "1")
# 1- Phase Monitor/Configuration
# 2- Outlet Restriction Configuration
# 4- Power Supply Status
# 3- Outlet Control/Config
- telnet_answer(telnet, "\r\n> ", "3")
+ telnet_answer(transport, "\r\n> ", "2")
+ telnet_answer(transport, "\r\n> ", "1")
+
+ # 3- Outlet Control/Config
+ #telnet_answer(transport, "\r\n> ", "3")
# 1- Outlet 1
# 2- Outlet 2
# ...
# n- Outlet n
- telnet_answer(telnet, "\r\n> ", str(port))
+ telnet_answer(transport, "\r\n> ", str(port))
# 1- Control Outlet
# 2- Configure Outlet
# 1- Control Outlet
- telnet_answer(telnet, "\r\n> ", "1")
+ telnet_answer(transport, "\r\n> ", "1")
# 1- Immediate On
# 2- Immediate Off
# 7- Cancel
# 3- Immediate Reboot
- telnet_answer(telnet, "\r\n> ", "3")
+ telnet_answer(transport, "\r\n> ", "3")
if not dryrun:
- telnet_answer(telnet,
+ telnet_answer(transport,
"Enter 'YES' to continue or <ENTER> to cancel", "YES\r\n")
- telnet_answer(telnet,
+ telnet_answer(transport,
"Press <ENTER> to continue...", "")
# Close
- telnet.close()
+ transport.close()
return 0
except EOFError, err:
if verbose:
logger.debug(err)
- if telnet:
- telnet.close()
+ if transport:
+ transport.close()
return errno.ECONNRESET
+ except socket.error, err:
+ if verbose:
+ logger.debug(err)
+ return errno.ETIMEDOUT
+
except Exception, err:
+ import traceback
+ traceback.print_exc()
if verbose:
logger.debug(err)
- if telnet:
- telnet.close()
+ if transport:
+ transport.close()
+ return "apc error: check password"
+
+def drac_reboot(ip, username, password, dryrun):
+ global verbose
+ ssh = None
+ try:
+ ssh = pyssh.Ssh(username, ip)
+ ssh.set_debuglevel(verbose)
+ ssh.open()
+ # Login
+ print "password"
+ telnet_answer(ssh, "password:", password)
+
+ # Testing Reboot ?
+ print "reset or power"
+ if dryrun:
+ telnet_answer(ssh, "[%s]#" % username, "getsysinfo")
+ else:
+ # Reset this machine
+ telnet_answer(ssh, "[%s]#" % username, "serveraction powercycle")
+
+ print "exit"
+ telnet_answer(ssh, "[%s]#" % username, "exit")
+
+ # Close
+ print "close"
+ output = ssh.close()
+ return 0
+
+ except socket.error, err:
+ print "exception"
+ import traceback
+ traceback.print_exc()
+ if verbose:
+ logger.debug(err)
+ if ssh:
+ output = ssh.close()
+ if verbose:
+ logger.debug(err)
return errno.ETIMEDOUT
+ except Exception, err:
+ print "exception"
+ import traceback
+ traceback.print_exc()
+ if verbose:
+ logger.debug(err)
+ if ssh:
+ output = ssh.close()
+ if verbose:
+ logger.debug(err)
+ return "drac error: check password"
+def ilo_reboot(ip, username, password, dryrun):
+ global verbose
-def baytech_reboot(ip, username, password, port):
- global dryrun, verbose
+ ssh = None
+
+ try:
+ ssh = pyssh.Ssh(username, ip)
+ ssh.set_debuglevel(verbose)
+ ssh.open()
+ # Login
+ print "password"
+ telnet_answer(ssh, "password:", password)
+
+ # User:vici logged-in to ILOUSE701N7N4.CS.Princeton.EDU(128.112.154.171)
+ # iLO Advanced 1.26 at 10:01:40 Nov 17 2006
+ # Server Name: USE701N7N400
+ # Server Power: On
+ #
+ # </>hpiLO->
+ print "cd system1"
+ telnet_answer(ssh, "</>hpiLO->", "cd system1")
+
+ # Reboot Outlet N (Y/N)?
+ print "reset or power"
+ if dryrun:
+ telnet_answer(ssh, "</system1>hpiLO->", "POWER")
+ else:
+ # Reset this machine
+ telnet_answer(ssh, "</system1>hpiLO->", "reset")
+
+ print "exit"
+ telnet_answer(ssh, "</system1>hpiLO->", "exit")
+
+ # Close
+ print "close"
+ output = ssh.close()
+ return 0
+
+ except socket.error, err:
+ print "exception"
+ import traceback
+ traceback.print_exc()
+ if verbose:
+ logger.debug(err)
+ if ssh:
+ output = ssh.close()
+ if verbose:
+ logger.debug(err)
+ return errno.ETIMEDOUT
+ except Exception, err:
+ print "exception"
+ import traceback
+ traceback.print_exc()
+ if verbose:
+ logger.debug(err)
+ if ssh:
+ output = ssh.close()
+ if verbose:
+ logger.debug(err)
+ return "ilo error: check password"
+
+def baytech_reboot(ip, username, password, port, dryrun):
+ global verbose
ssh = None
+ #verbose = 1
try:
ssh = pyssh.Ssh(username, ip)
+ ssh.set_debuglevel(verbose)
ssh.open()
# Login
telnet_answer(ssh, "Enter Request :", "5")
# Reboot N
- telnet_answer(ssh, "DS-RPC>", "Reboot %d" % port)
+ try:
+ telnet_answer(ssh, "DS-RPC>", "Reboot %d" % port)
+ except ExceptionNotFound, msg:
+ # one machine is configured to ask for a username,
+ # even after login...
+ print "msg: %s" % msg
+ ssh.write(username + "\r\n")
+ telnet_answer(ssh, "DS-RPC>", "Reboot %d" % port)
+
# Reboot Outlet N (Y/N)?
if dryrun:
# Close
output = ssh.close()
- if verbose:
- logger.debug(err)
return 0
- except Exception, err:
+ except socket.error, err:
+ print "exception"
+ import traceback
+ traceback.print_exc()
if verbose:
logger.debug(err)
if ssh:
if verbose:
logger.debug(err)
return errno.ETIMEDOUT
+ except Exception, err:
+ print "exception"
+ import traceback
+ traceback.print_exc()
+ if verbose:
+ logger.debug(err)
+ if ssh:
+ output = ssh.close()
+ if verbose:
+ logger.debug(err)
+ return "baytech error: check password"
### rebooting european BlackBox PSE boxes
# Thierry Parmentelat - May 11 2005
# curl --http1.0 --basic --user <username>:<password> --data P<port>=r \
# http://<hostname>:<http_port>/cmd.html && echo OK
-def bbpse_reboot (pcu_ip,username,password,port_in_pcu,http_port):
+def bbpse_reboot (pcu_ip,username,password,port_in_pcu,http_port, dryrun):
- global dryrun, verbose
+ global verbose
url = "http://%s:%d/cmd.html" % (pcu_ip,http_port)
data= "P%d=r" % port_in_pcu
except urllib2.URLError,err:
logger.info('Could not open http connection', err)
- return -1
+ return "bbpse error"
### rebooting x10toggle based systems addressed by port
# Marc E. Fiuczynski - May 31 2005
# uses ssh and password to login to an account
# that will cause the system to be powercycled.
-def x10toggle_reboot(ip, username, password, port):
- global dryrun, verbose
+def x10toggle_reboot(ip, username, password, port, dryrun):
+ global verbose
ssh = None
try:
out += "; output follows:\n" + data
raise Exception, out
-def racadm_reboot(ip, username, password, port):
- global dryrun, verbose
+def racadm_reboot(ip, username, password, port, dryrun):
+ global verbose
try:
cmd = "/usr/sbin/racadm"
logger.debug(err)
return errno.ETIMEDOUT
+def pcu_name(pcu):
+ if pcu['hostname'] is not None and pcu['hostname'] is not "":
+ return pcu['hostname']
+ elif pcu['ip'] is not None and pcu['ip'] is not "":
+ return pcu['ip']
+ else:
+ return None
+
+def get_pcu_values(pcu_id):
+ # TODO: obviously, this shouldn't be loaded each time...
+ import soltesz
+ fb =soltesz.dbLoad("findbadpcus")
+
+ try:
+ values = fb['nodes']["id_%s" % pcu_id]['values']
+ except:
+ values = None
+
+ return values
+
+def reboot_new(nodename, continue_probe, dryrun):
+
+ pcu = plc.getpcu(nodename)
+ if not pcu:
+ return False
+
+ values = get_pcu_values(pcu['pcu_id'])
+ if values == None:
+ return False
+
+ # Try the PCU first
+ logger.debug("Trying PCU %s %s" % (pcu['hostname'], pcu['model']))
+
+ # DataProbe iPal (many sites)
+ if continue_probe and values['model'].find("Dataprobe IP-41x/IP-81x") >= 0:
+ if values['portstatus']['23'] == "open":
+ rb_ret = ipal_reboot(pcu_name(values),
+ values['password'],
+ pcu[nodename],
+ dryrun)
+ else:
+ rb_ret = "Unsupported_Port"
+
+
+ # APC Masterswitch (Berkeley)
+ elif continue_probe and values['model'].find("APC AP79xx/Masterswitch") >= 0:
+ if values['portstatus']['22'] == "open" or \
+ values['portstatus']['23'] == "open":
+ rb_ret = apc_reboot(pcu_name(values),
+ values['username'],
+ values['password'],
+ pcu[nodename],
+ values['portstatus'],
+ dryrun)
+ else:
+ rb_ret = "Unsupported_Port"
+ # BayTech DS4-RPC
+ elif continue_probe and values['model'].find("Baytech DS4-RPC") >= 0:
+ if values['portstatus']['22'] == "open":
+ rb_ret = baytech_reboot(pcu_name(values),
+ values['username'],
+ values['password'],
+ pcu[nodename],
+ dryrun)
+ else:
+ rb_ret = "Unsupported_Port"
+
+
+ # iLO
+ elif continue_probe and values['model'].find("HP iLO") >= 0:
+ if values['portstatus']['22'] == "open":
+ rb_ret = ilo_reboot(pcu_name(values),
+ values['username'],
+ values['password'],
+ dryrun)
+ else:
+ rb_ret = "Unsupported_Port"
+
+ # DRAC ssh
+ elif continue_probe and values['model'].find("Dell RAC") >= 0:
+ if values['portstatus']['22'] == "open":
+ rb_ret = drac_reboot(pcu_name(values),
+ values['username'],
+ values['password'],
+ dryrun)
+ else:
+ rb_ret = "Unsupported_Port"
+
+
+ # BlackBox PSExxx-xx (e.g. PSE505-FR)
+ elif continue_probe and \
+ (values['model'].find("BlackBox PS5xx") >= 0 or
+ values['model'].find("ePowerSwitch 1/4/8x") >=0 ):
+ if values['portstatus']['80'] == "open":
+ rb_ret = bbpse_reboot(pcu_name(values),
+ values['username'],
+ values['password'],
+ pcu[nodename],
+ 80,
+ dryrun)
+ else:
+ rb_ret = "Unsupported_PCU"
+
+ # x10toggle
+ elif continue_probe and values['protocol'] == "ssh" and \
+ values['model'] == "x10toggle":
+ rb_ret = x10toggle_reboot(pcu_name(values),
+ values['username'],
+ values['password'],
+ pcu[nodename],
+ dryrun)
+ # ????
+ elif continue_probe and values['protocol'] == "racadm" and \
+ values['model'] == "RAC":
+ rb_ret = racadm_reboot(pcu_name(values),
+ values['username'],
+ values['password'],
+ pcu[nodename],
+ dryrun)
+ elif continue_probe:
+ rb_ret = "Unsupported_PCU"
+
+ elif continue_probe == False:
+ if 'portstatus' in values:
+ rb_ret = "NetDown"
+ else:
+ rb_ret = "Not_Run"
+ else:
+ rb_ret = -1
+
+ if rb_ret != 0:
+ return False
+ else:
+ return True
+
+
# Returns true if rebooted via PCU
-def reboot(nodename):
+def reboot(nodename, dryrun):
pcu = plc.getpcu(nodename)
if not pcu:
plc.nodePOD(nodename)
logger.debug("Trying PCU %s %s" % (pcu['hostname'], pcu['model']))
# APC Masterswitch (Berkeley)
- if pcu['protocol'] == "telnet" and pcu['model'] == "APC Masterswitch":
- err = apc_reboot(pcu['ip'], pcu['username'],pcu['password'], pcu[nodename])
+ if pcu['model'] == "APC Masterswitch":
+ err = apc_reboot(pcu['ip'], pcu['username'],pcu['password'],
+ pcu[nodename], pcu['protocol'], dryrun)
# DataProbe iPal (many sites)
elif pcu['protocol'] == "telnet" and pcu['model'].find("IP-4") >= 0:
- err = ipal_reboot(pcu['ip'],pcu['password'], pcu[nodename])
+ err = ipal_reboot(pcu['ip'],pcu['password'], pcu[nodename], dryrun)
# BayTech DS4-RPC
elif pcu['protocol'] == "ssh" and \
(pcu['model'].find("Baytech") >= 0 or pcu['model'].find("DS4") >= 0):
- err = baytech_reboot(pcu['ip'], pcu['username'],pcu['password'], pcu[nodename])
+ err = baytech_reboot(pcu['ip'], pcu['username'],pcu['password'], pcu[nodename], dryrun)
# BlackBox PSExxx-xx (e.g. PSE505-FR)
elif pcu['protocol'] == "http" and (pcu['model'] == "bbpse"):
- err = bbpse_reboot(pcu['ip'], pcu['username'], pcu['password'], pcu[nodename],80)
+ err = bbpse_reboot(pcu['ip'], pcu['username'], pcu['password'], pcu[nodename],80, dryrun)
# x10toggle
elif pcu['protocol'] == "ssh" and (pcu['model'] == "x10toggle"):
- err = x10toggle_reboot(pcu['ip'], pcu['username'],pcu['password'], pcu[nodename])
+ err = x10toggle_reboot(pcu['ip'], pcu['username'],pcu['password'], pcu[nodename], dryrun)
- # x10toggle
+ #
elif pcu['protocol'] == "racadm" and (pcu['model'] == "RAC"):
- err = racadm_reboot(pcu['ip'], pcu['username'],pcu['password'], pcu_[nodename])
+ err = racadm_reboot(pcu['ip'], pcu['username'],pcu['password'], pcu_[nodename], dryrun)
# Unknown or unsupported