#!/usr/bin/python
-
+#
# Copyright (c) 2003 Intel Corporation
# All rights reserved.
#
import ModelOptions
-def Run( vars, log ):
+def Run(vars, log):
"""
Find any new large block devices we can add to the vservers volume group
ROOT_MOUNTED the node root file system is mounted
"""
- log.write( "\n\nStep: Checking for unused disks to add to LVM.\n" )
+ log.write("\n\nStep: Checking for unused disks to add to LVM.\n")
# make sure we have the variables we need
try:
- SYSIMG_PATH= vars["SYSIMG_PATH"]
+ SYSIMG_PATH = vars["SYSIMG_PATH"]
if SYSIMG_PATH == "":
- raise ValueError, "SYSIMG_PATH"
+ raise ValueError("SYSIMG_PATH")
- MINIMUM_DISK_SIZE= int(vars["MINIMUM_DISK_SIZE"])
+ MINIMUM_DISK_SIZE = int(vars["MINIMUM_DISK_SIZE"])
- PARTITIONS= vars["PARTITIONS"]
+ PARTITIONS = vars["PARTITIONS"]
if PARTITIONS == None:
- raise ValueError, "PARTITIONS"
+ raise ValueError("PARTITIONS")
- NODE_MODEL_OPTIONS= vars["NODE_MODEL_OPTIONS"]
- except KeyError, var:
- raise BootManagerException, "Missing variable in vars: %s\n" % var
- except ValueError, var:
- raise BootManagerException, "Variable in vars, shouldn't be: %s\n" % var
+ NODE_MODEL_OPTIONS = vars["NODE_MODEL_OPTIONS"]
+ except KeyError as var:
+ raise BootManagerException("Missing variable in vars: {}\n".format(var))
+ except ValueError as var:
+ raise BootManagerException("Variable in vars, shouldn't be: {}\n".format(var))
- all_devices= systeminfo.get_block_device_list(vars, log)
+ all_devices = systeminfo.get_block_device_list(vars, log)
# will contain the new devices to add to the volume group
- new_devices= []
+ new_devices = []
# total amount of new space in gb
- extended_gb_size= 0
+ extended_gb_size = 0
for device in all_devices.keys():
- (major,minor,blocks,gb_size,readonly)= all_devices[device]
+ (major, minor, blocks, gb_size, readonly) = all_devices[device]
if device[:14] == "/dev/planetlab":
- log.write( "Skipping device %s in volume group.\n" % device )
+ log.write("Skipping device {} in volume group.\n".format(device))
continue
if readonly:
- log.write( "Skipping read only device %s\n" % device )
+ log.write("Skipping read only device {}\n".format(device))
continue
if gb_size < MINIMUM_DISK_SIZE:
- log.write( "Skipping too small device %s (%4.2f)\n" %
- (device,gb_size) )
+ log.write("Skipping too small device {} ({:4.2f}) Gb\n"\
+ .format(device, gb_size))
continue
- log.write( "Checking device %s to see if it is part " \
- "of the volume group.\n" % device )
+ log.write("Checking device {} to see if it is part " \
+ "of the volume group.\n".format(device))
# this is the lvm partition, if it exists on that device
- lvm_partition= InstallPartitionDisks.get_partition_path_from_device( device, vars, log )
- cmd = "pvdisplay %s | grep -q 'planetlab'" % lvm_partition
- already_added= utils.sysexec_noerr(cmd, log)
+ lvm_partition = InstallPartitionDisks.get_partition_path_from_device(device, vars, log)
+ cmd = "pvdisplay {} | grep -q 'planetlab'".format(lvm_partition)
+ already_added = utils.sysexec_noerr(cmd, log, shell=True)
if already_added:
- log.write( "It appears %s is part of the volume group, continuing.\n" %
- device )
+ log.write("It appears {} is part of the volume group, continuing.\n"\
+ .format(device))
continue
# just to be extra paranoid, ignore the device if it already has
# an lvm partition on it (new disks won't have this, and that is
# what this code is for, so it should be ok).
- cmd = "sfdisk -l %s | grep -q 'Linux LVM'" % device
- has_lvm= utils.sysexec_noerr(cmd, log)
+ cmd = "parted --script --list {} | grep -q lvm$".format(device)
+ has_lvm = utils.sysexec_noerr(cmd, log)
if has_lvm:
- log.write( "It appears %s has lvm already setup on it.\n" % device)
+ log.write("It appears {} has lvm already setup on it.\n".format(device))
paranoid = False
if paranoid:
- log.write("To paranoid to add %s to vservers lvm.\n" % device)
+ log.write("Too paranoid to add {} to vservers lvm.\n".format(device))
continue
- if not InstallPartitionDisks.single_partition_device( device, vars, log ):
- log.write( "Unable to partition %s, not using it.\n" % device )
+ if not InstallPartitionDisks.single_partition_device(device, vars, log):
+ log.write("Unable to partition {}, not using it.\n".format(device))
continue
- log.write( "Successfully partitioned %s\n" % device )
+ log.write("Successfully partitioned {}\n".format(device))
if NODE_MODEL_OPTIONS & ModelOptions.RAWDISK:
- log.write( "Running on a raw disk node, not using it.\n" )
+ log.write("Running on a raw disk node, not using it.\n")
continue
- part_path= InstallPartitionDisks.get_partition_path_from_device( device,
- vars, log )
+ part_path = InstallPartitionDisks.get_partition_path_from_device(device,
+ vars, log)
- log.write( "Attempting to add %s to the volume group\n" % device )
+ log.write("Attempting to add {} to the volume group\n".format(device))
- if not InstallPartitionDisks.create_lvm_physical_volume( part_path,
- vars, log ):
- log.write( "Unable to create lvm physical volume %s, not using it.\n" %
- part_path )
+ if not InstallPartitionDisks.create_lvm_physical_volume(part_path,
+ vars, log):
+ log.write("Unable to create lvm physical volume {}, not using it.\n"\
+ .format(part_path))
continue
- log.write( "Adding %s to list of devices to add to " \
- "planetlab volume group.\n" % device )
+ log.write("Adding {} to list of devices to add to "
+ "planetlab volume group.\n".format(device))
- extended_gb_size= extended_gb_size + gb_size
- new_devices.append( part_path )
+ extended_gb_size = extended_gb_size + gb_size
+ new_devices.append(part_path)
if len(new_devices) > 0:
- log.write( "Extending planetlab volume group.\n" )
+ log.write("Extending planetlab volume group.\n")
- log.write( "Unmounting disks.\n" )
+ log.write("Unmounting disks.\n")
try:
# backwards compat, though, we should never hit this case post PL 3.2
- os.stat("%s/rcfs/taskclass"%SYSIMG_PATH)
- utils.sysexec_noerr( "chroot %s umount /rcfs" % SYSIMG_PATH, log )
- except OSError, e:
+ os.stat("{}/rcfs/taskclass".format(SYSIMG_PATH))
+ utils.sysexec_chroot_noerr(SYSIMG_PATH, "umount /rcfs", log)
+ except OSError as e:
pass
# umount in order to extend disk size
- utils.sysexec_noerr( "umount %s/proc" % SYSIMG_PATH, log )
- utils.sysexec_noerr( "umount %s/vservers" % SYSIMG_PATH, log )
- utils.sysexec_noerr( "umount %s" % SYSIMG_PATH, log )
- utils.sysexec( "vgchange -an", log )
+ utils.sysexec_noerr("umount {}/proc".format(SYSIMG_PATH), log)
+ utils.sysexec_noerr("umount {}/vservers".format(SYSIMG_PATH), log)
+ utils.sysexec_noerr("umount {}".format(SYSIMG_PATH), log)
+ utils.sysexec("vgchange -an", log)
- vars['ROOT_MOUNTED']= 0
+ vars['ROOT_MOUNTED'] = 0
while True:
- cmd = "vgextend planetlab %s" % string.join(new_devices," ")
- if not utils.sysexec_noerr( cmd, log ):
- log.write( "Failed to add physical volumes %s to " \
- "volume group, continuing.\n" % string.join(new_devices," "))
+ cmd = "vgextend planetlab {}".format(" ".join(new_devices))
+ if not utils.sysexec_noerr(cmd, log):
+ log.write("Failed to add physical volumes {} to "\
+ "volume group, continuing.\n".format(" ".join(new_devices)))
res = 1
break
# now, get the number of unused extents, and extend the vserver
# logical volume by that much.
- remaining_extents= \
- InstallPartitionDisks.get_remaining_extents_on_vg( vars, log )
+ remaining_extents = \
+ InstallPartitionDisks.get_remaining_extents_on_vg(vars, log)
- log.write( "Extending vservers logical volume.\n" )
- utils.sysexec( "vgchange -ay", log )
- cmd = "lvextend -l +%s %s" % (remaining_extents, PARTITIONS["vservers"])
+ log.write("Extending vservers logical volume.\n")
+ utils.sysexec("vgchange -ay", log)
+ cmd = "lvextend -l +{} {}".format(remaining_extents, PARTITIONS["vservers"])
if not utils.sysexec_noerr(cmd, log):
- log.write( "Failed to extend vservers logical volume, continuing\n" )
+ log.write("Failed to extend vservers logical volume, continuing\n")
res = 1
break
- log.write( "making the ext3 filesystem match new logical volume size.\n" )
+ log.write("making the ext filesystem match new logical volume size.\n")
- vars['ROOT_MOUNTED']= 1
- cmd = "mount %s %s" % (PARTITIONS["root"],SYSIMG_PATH)
- utils.sysexec_noerr( cmd, log )
- cmd = "mount %s %s/vservers" % \
- (PARTITIONS["vservers"],SYSIMG_PATH)
- utils.sysexec_noerr( cmd, log )
- cmd = "ext2online %s/vservers" % SYSIMG_PATH
+ vars['ROOT_MOUNTED'] = 1
+ cmd = "mount {} {}".format(PARTITIONS["root"], SYSIMG_PATH)
+ utils.sysexec_noerr(cmd, log)
+ cmd = "mount {} {}/vservers".format(PARTITIONS["vservers"], SYSIMG_PATH)
+ utils.sysexec_noerr(cmd, log)
+ cmd = "resize2fs {}".format(PARTITIONS["vservers"])
resize = utils.sysexec_noerr(cmd,log)
- utils.sysexec_noerr( "umount %s/vservers" % SYSIMG_PATH, log )
- utils.sysexec_noerr( "umount %s" % SYSIMG_PATH, log )
- vars['ROOT_MOUNTED']= 0
+ utils.sysexec_noerr("umount {}/vservers".format(SYSIMG_PATH), log)
+ utils.sysexec_noerr("umount {}".format(SYSIMG_PATH), log)
+ vars['ROOT_MOUNTED'] = 0
- utils.sysexec( "vgchange -an", log )
+ utils.sysexec("vgchange -an", log)
if not resize:
- log.write( "Failed to resize vservers partition, continuing.\n" )
+ log.write("Failed to resize vservers partition, continuing.\n")
res = 1
break
else:
- log.write( "Extended vservers partition by %4.2f GB\n" %
- extended_gb_size )
+ log.write("Extended vservers partition by {:4.2f} Gb\n"\
+ .format(extended_gb_size))
res = 1
break
else:
- log.write( "No new disk devices to add to volume group.\n" )
+ log.write("No new disk devices to add to volume group.\n")
res = 1
return res