X-Git-Url: http://git.onelab.eu/?a=blobdiff_plain;f=ofproto%2Fin-band.c;h=e04ae60926561dbeea843c475d12bc2bf62c1981;hb=007948177581f3b3dad188221593d0e4bdca6ba0;hp=5f3b9bfeaba6d1115035048131c15b0ef935c2ef;hpb=fc08b7a2397ef0cf55014c1ee159599fb420b73e;p=sliver-openvswitch.git diff --git a/ofproto/in-band.c b/ofproto/in-band.c index 5f3b9bfea..e04ae6092 100644 --- a/ofproto/in-band.c +++ b/ofproto/in-band.c @@ -41,166 +41,6 @@ VLOG_DEFINE_THIS_MODULE(in_band); -/* In-band control allows a single network to be used for OpenFlow traffic and - * other data traffic. See ovs-vswitchd.conf.db(5) for a description of - * configuring in-band control. - * - * This comment is an attempt to describe how in-band control works at a - * wire- and implementation-level. Correctly implementing in-band - * control has proven difficult due to its many subtleties, and has thus - * gone through many iterations. Please read through and understand the - * reasoning behind the chosen rules before making modifications. - * - * In Open vSwitch, in-band control is implemented as "hidden" flows (in that - * they are not visible through OpenFlow) and at a higher priority than - * wildcarded flows can be set up by through OpenFlow. This is done so that - * the OpenFlow controller cannot interfere with them and possibly break - * connectivity with its switches. It is possible to see all flows, including - * in-band ones, with the ovs-appctl "bridge/dump-flows" command. - * - * The Open vSwitch implementation of in-band control can hide traffic to - * arbitrary "remotes", where each remote is one TCP port on one IP address. - * Currently the remotes are automatically configured as the in-band OpenFlow - * controllers plus the OVSDB managers, if any. (The latter is a requirement - * because OVSDB managers are responsible for configuring OpenFlow controllers, - * so if the manager cannot be reached then OpenFlow cannot be reconfigured.) - * - * The following rules (with the OFPP_NORMAL action) are set up on any bridge - * that has any remotes: - * - * (a) DHCP requests sent from the local port. - * (b) ARP replies to the local port's MAC address. - * (c) ARP requests from the local port's MAC address. - * - * In-band also sets up the following rules for each unique next-hop MAC - * address for the remotes' IPs (the "next hop" is either the remote - * itself, if it is on a local subnet, or the gateway to reach the remote): - * - * (d) ARP replies to the next hop's MAC address. - * (e) ARP requests from the next hop's MAC address. - * - * In-band also sets up the following rules for each unique remote IP address: - * - * (f) ARP replies containing the remote's IP address as a target. - * (g) ARP requests containing the remote's IP address as a source. - * - * In-band also sets up the following rules for each unique remote (IP,port) - * pair: - * - * (h) TCP traffic to the remote's IP and port. - * (i) TCP traffic from the remote's IP and port. - * - * The goal of these rules is to be as narrow as possible to allow a - * switch to join a network and be able to communicate with the - * remotes. As mentioned earlier, these rules have higher priority - * than the controller's rules, so if they are too broad, they may - * prevent the controller from implementing its policy. As such, - * in-band actively monitors some aspects of flow and packet processing - * so that the rules can be made more precise. - * - * In-band control monitors attempts to add flows into the datapath that - * could interfere with its duties. The datapath only allows exact - * match entries, so in-band control is able to be very precise about - * the flows it prevents. Flows that miss in the datapath are sent to - * userspace to be processed, so preventing these flows from being - * cached in the "fast path" does not affect correctness. The only type - * of flow that is currently prevented is one that would prevent DHCP - * replies from being seen by the local port. For example, a rule that - * forwarded all DHCP traffic to the controller would not be allowed, - * but one that forwarded to all ports (including the local port) would. - * - * As mentioned earlier, packets that miss in the datapath are sent to - * the userspace for processing. The userspace has its own flow table, - * the "classifier", so in-band checks whether any special processing - * is needed before the classifier is consulted. If a packet is a DHCP - * response to a request from the local port, the packet is forwarded to - * the local port, regardless of the flow table. Note that this requires - * L7 processing of DHCP replies to determine whether the 'chaddr' field - * matches the MAC address of the local port. - * - * It is interesting to note that for an L3-based in-band control - * mechanism, the majority of rules are devoted to ARP traffic. At first - * glance, some of these rules appear redundant. However, each serves an - * important role. First, in order to determine the MAC address of the - * remote side (controller or gateway) for other ARP rules, we must allow - * ARP traffic for our local port with rules (b) and (c). If we are - * between a switch and its connection to the remote, we have to - * allow the other switch's ARP traffic to through. This is done with - * rules (d) and (e), since we do not know the addresses of the other - * switches a priori, but do know the remote's or gateway's. Finally, - * if the remote is running in a local guest VM that is not reached - * through the local port, the switch that is connected to the VM must - * allow ARP traffic based on the remote's IP address, since it will - * not know the MAC address of the local port that is sending the traffic - * or the MAC address of the remote in the guest VM. - * - * With a few notable exceptions below, in-band should work in most - * network setups. The following are considered "supported' in the - * current implementation: - * - * - Locally Connected. The switch and remote are on the same - * subnet. This uses rules (a), (b), (c), (h), and (i). - * - * - Reached through Gateway. The switch and remote are on - * different subnets and must go through a gateway. This uses - * rules (a), (b), (c), (h), and (i). - * - * - Between Switch and Remote. This switch is between another - * switch and the remote, and we want to allow the other - * switch's traffic through. This uses rules (d), (e), (h), and - * (i). It uses (b) and (c) indirectly in order to know the MAC - * address for rules (d) and (e). Note that DHCP for the other - * switch will not work unless an OpenFlow controller explicitly lets this - * switch pass the traffic. - * - * - Between Switch and Gateway. This switch is between another - * switch and the gateway, and we want to allow the other switch's - * traffic through. This uses the same rules and logic as the - * "Between Switch and Remote" configuration described earlier. - * - * - Remote on Local VM. The remote is a guest VM on the - * system running in-band control. This uses rules (a), (b), (c), - * (h), and (i). - * - * - Remote on Local VM with Different Networks. The remote - * is a guest VM on the system running in-band control, but the - * local port is not used to connect to the remote. For - * example, an IP address is configured on eth0 of the switch. The - * remote's VM is connected through eth1 of the switch, but an - * IP address has not been configured for that port on the switch. - * As such, the switch will use eth0 to connect to the remote, - * and eth1's rules about the local port will not work. In the - * example, the switch attached to eth0 would use rules (a), (b), - * (c), (h), and (i) on eth0. The switch attached to eth1 would use - * rules (f), (g), (h), and (i). - * - * The following are explicitly *not* supported by in-band control: - * - * - Specify Remote by Name. Currently, the remote must be - * identified by IP address. A naive approach would be to permit - * all DNS traffic. Unfortunately, this would prevent the - * controller from defining any policy over DNS. Since switches - * that are located behind us need to connect to the remote, - * in-band cannot simply add a rule that allows DNS traffic from - * the local port. The "correct" way to support this is to parse - * DNS requests to allow all traffic related to a request for the - * remote's name through. Due to the potential security - * problems and amount of processing, we decided to hold off for - * the time-being. - * - * - Differing Remotes for Switches. All switches must know - * the L3 addresses for all the remotes that other switches - * may use, since rules need to be set up to allow traffic related - * to those remotes through. See rules (f), (g), (h), and (i). - * - * - Differing Routes for Switches. In order for the switch to - * allow other switches to connect to a remote through a - * gateway, it allows the gateway's traffic through with rules (d) - * and (e). If the routes to the remote differ for the two - * switches, we will not know the MAC address of the alternate - * gateway. - */ - /* Priorities used in classifier for in-band rules. These values are higher * than any that may be set with OpenFlow, and "18" kind of looks like "IB". * The ordering of priorities is not important because all of the rules set up