OFPTC11_TABLE_MISS_MASK is not a valid configuration, but to indicate
there are only 2 bits being used for table miss configuration. Move
it out of the enum definition.
Reported-by: Simon Horman <horms@verge.net.au>
Signed-off-by: Andy Zhou <azhou@nicira.com>
Signed-off-by: Ben Pfaff <blp@nicira.com>
pipeline (OpenFlow 1.0
behavior). */
OFPTC11_TABLE_MISS_DROP = 2 << 0, /* Drop the packet. */
pipeline (OpenFlow 1.0
behavior). */
OFPTC11_TABLE_MISS_DROP = 2 << 0, /* Drop the packet. */
- OFPTC11_TABLE_MISS_MASK = 3
+#define OFPTC11_TABLE_MISS_MASK (3 << 0)
};
/* Flow setup and teardown (controller -> datapath). */
};
/* Flow setup and teardown (controller -> datapath). */