The extensions variable is not expected to be in the configuration file if the latest...
[bootmanager.git] / source / steps / GetAndUpdateNodeDetails.py
index eb8dedb..78d77f6 100644 (file)
@@ -1,36 +1,45 @@
+#!/usr/bin/python
+#
+# Copyright (c) 2003 Intel Corporation
+# All rights reserved.
+#
+# Copyright (c) 2004-2006 The Trustees of Princeton University
+# All rights reserved.
+
+import sys, traceback
 import string
 
 from Exceptions import *
 import BootAPI
-
-
-SKIP_MODEL_STRING= "/minhw"
-
+import ModelOptions
 
 def Run( vars, log ):
     """
-    Contact PLC and get the attributes for this node. Also, if the node model
-    string ends in SKIP_MODEL_STRING, override the hardware requirements
-    configuration value, and skip the checks.
+
+    Contact PLC and get the attributes for this node. Also, parse in
+    options from the node model strong.
 
     Also, update any node network settings at PLC, minus the ip address,
     so, upload the mac (if node_id was in conf file), gateway, network,
     broadcast, netmask, dns1/2, and the hostname/domainname.
 
     Expect the following keys to be set:
-    BOOT_CD_VERSION          A tuple of the current bootcd version
     SKIP_HARDWARE_REQUIREMENT_CHECK     Whether or not we should skip hardware
                                         requirement checks
                                         
     The following keys are set/updated:
-    WAS_NODE_ID_IN_CONF      Set to 1 if the node id was in the conf file
-    WAS_NODE_KEY_IN_CONF     Set to 1 if the node key was in the conf file
-    BOOT_STATE               The current node boot state
-    NODE_MODEL               The user specified model of this node
-    NETWORK_SETTINGS         A dictionary of the values of the network settings
+    WAS_NODE_ID_IN_CONF                 Set to 1 if the node id was in the conf file
+    WAS_NODE_KEY_IN_CONF                Set to 1 if the node key was in the conf file
+    BOOT_STATE                          The current node boot state
+    NODE_MODEL                          The user specified model of this node
+    NODE_MODEL_OPTIONS                  The options extracted from the user specified
+                                                model of this node 
     SKIP_HARDWARE_REQUIREMENT_CHECK     Whether or not we should skip hardware
-                                        requirement checks
-                                        
+                                                requirement checks
+    NODE_SESSION                        The session value returned from BootGetNodeDetails
+    INTERFACES                          The network interfaces associated with this node
+    INTERFACE_SETTINGS                  A dictionary of the values of the interface settings
+    
     Return 1 if able to contact PLC and get node info.
     Raise a BootManagerException if anything fails.
     """
@@ -39,17 +48,13 @@ def Run( vars, log ):
 
     # make sure we have the variables we need
     try:
-        BOOT_CD_VERSION= vars["BOOT_CD_VERSION"]
-        if BOOT_CD_VERSION == "":
-            raise ValueError, "BOOT_CD_VERSION"
-
         SKIP_HARDWARE_REQUIREMENT_CHECK= vars["SKIP_HARDWARE_REQUIREMENT_CHECK"]
         if SKIP_HARDWARE_REQUIREMENT_CHECK == "":
             raise ValueError, "SKIP_HARDWARE_REQUIREMENT_CHECK"
 
-        NETWORK_SETTINGS= vars["NETWORK_SETTINGS"]
-        if NETWORK_SETTINGS == "":
-            raise ValueError, "NETWORK_SETTINGS"
+        INTERFACE_SETTINGS= vars["INTERFACE_SETTINGS"]
+        if INTERFACE_SETTINGS == "":
+            raise ValueError, "INTERFACE_SETTINGS"
 
         WAS_NODE_ID_IN_CONF= vars["WAS_NODE_ID_IN_CONF"]
         if WAS_NODE_ID_IN_CONF == "":
@@ -64,59 +69,75 @@ def Run( vars, log ):
     except ValueError, var:
         raise BootManagerException, "Variable in vars, shouldn't be: %s\n" % var
 
+    node_details= BootAPI.call_api_function( vars, "GetNodes", 
+                                             (vars['NODE_ID'], 
+                                              ['boot_state', 'nodegroup_ids', 'interface_ids', 'model', 'site_id']))[0]
 
-    details= BootAPI.call_api_function( vars, "BootGetNodeDetails", () )
-
-    vars['BOOT_STATE']= details['boot_state']
-    vars['NODE_MODEL']= string.strip(details['model'])
-
+    vars['BOOT_STATE']= node_details['boot_state']
+    vars['RUN_LEVEL']= node_details['boot_state']
+    vars['NODE_MODEL']= string.strip(node_details['model'])
+    vars['SITE_ID'] = node_details['site_id'] 
     log.write( "Successfully retrieved node record.\n" )
     log.write( "Current boot state: %s\n" % vars['BOOT_STATE'] )
     log.write( "Node make/model: %s\n" % vars['NODE_MODEL'] )
     
-    # if the end of NODE_MODEL string ends in SKIP_MODEL_STRING, skip hardware
-    # requirement checks (overrides configuration)
+    # parse in the model options from the node_model string
     model= vars['NODE_MODEL']
-    len_skip_str= len(SKIP_MODEL_STRING)
-    if model[-len_skip_str:] == SKIP_MODEL_STRING:
-        vars['SKIP_HARDWARE_REQUIREMENT_CHECK']= 1
+    options= ModelOptions.Get(model)
+    vars['NODE_MODEL_OPTIONS']=options
+
+    # Check if we should skip hardware requirement check
+    if options & ModelOptions.MINHW:
+        vars['SKIP_HARDWARE_REQUIREMENT_CHECK']=1
         log.write( "node model indicates override to hardware requirements.\n" )
-        
 
     # this contains all the node networks, for now, we are only concerned
     # in the primary network
-    node_networks= details['networks']
+    interfaces= BootAPI.call_api_function( vars, "GetInterfaces", (node_details['interface_ids'],))
     got_primary= 0
-    for network in node_networks:
+    for network in interfaces:
         if network['is_primary'] == 1:
+            log.write( "Primary network as returned from PLC: %s\n" % str(network) )
             got_primary= 1
             break
 
     if not got_primary:
         raise BootManagerException, "Node did not have a primary network."
+
+    vars['INTERFACES']= interfaces
     
-    log.write( "Primary network as returned from PLC: %s\n" % str(network) )
-
-    # if we got this far, the ip on the floppy and the ip in plc match,
-    # make the rest of the PLC information match whats on the floppy
-    network['method']= NETWORK_SETTINGS['method']
-
-    # only nodes that have the node_id specified directly in the configuration
-    # file can change their mac address
-    if WAS_NODE_ID_IN_CONF == 1:
-        network['mac']= NETWORK_SETTINGS['mac']
-        
-    network['gateway']= NETWORK_SETTINGS['gateway']
-    network['network']= NETWORK_SETTINGS['network']
-    network['broadcast']= NETWORK_SETTINGS['broadcast']
-    network['netmask']= NETWORK_SETTINGS['netmask']
-    network['dns1']= NETWORK_SETTINGS['dns1']
-    network['dns2']= NETWORK_SETTINGS['dns2']
-    
-    log.write( "Updating network settings at PLC to match floppy " \
-               "(except for node ip).\n" )
-    update_vals= {}
-    update_vals['primary_network']= network
-    BootAPI.call_api_function( vars, "BootUpdateNode", (update_vals,) )
+    # call getNodeFlavour and store in VARS['node_flavour']
+    try:
+        node_flavour = BootAPI.call_api_function(vars, "GetNodeFlavour", (vars['NODE_ID'], ) )
+    except:
+        log.write("GetNodeFlavour failed, not fatal if the node flavor is available in ``configuration''\n")
+        pass
     
+    flavour_keys = [
+            'virt',# 'vs' or 'lxc'
+            'nodefamily',# the basename for downloading nodeimage
+            'extensions',# extensions to be applied on top of the base nodeimage
+            'plain'# false if compressed image, true if not
+            ]
+
+    # MyPLC 5.0 workaround
+    try:
+        if (vars['extensions']==''):
+            vars['extensions']=[]
+    except:
+        pass
+
+    for k in flavour_keys:
+        # Support MyPLC <5.2
+        if (not vars.has_key(k)):
+            try:
+                vars[k] = node_flavour[k]
+            except:
+                exc_type, exc_value, exc_traceback = sys.exc_info()
+                lines=traceback.format_exception(exc_type,exc_value,exc_traceback)
+                for line in lines: log.write(line)
+                raise BootManagerException ("Could not call GetNodeFlavour - need PLCAPI-5.2")
+
+    log.write ("NodeFlavour as returned from PLC: %s\n"%node_flavour)
+
     return 1