svn merge -r 12308:13112 https://svn.planet-lab.org/svn/Monitor/branches/2.0/
[monitor.git] / pcucontrol / reboot.py
index 9d171a2..5744141 100755 (executable)
@@ -11,13 +11,12 @@ import urllib2
 import urllib
 import threading, popen2
 import array, struct
-from monitor.wrapper import plc
 import base64
 from subprocess import PIPE, Popen
 import pcucontrol.transports.ssh.pxssh as pxssh
 import pcucontrol.transports.ssh.pexpect as pexpect
 import socket
-from monitor.util import command
+
 
 
 # Use our versions of telnetlib and pyssh
@@ -25,8 +24,6 @@ sys.path.insert(0, os.path.dirname(sys.argv[0]))
 import pcucontrol.transports.telnetlib as telnetlib
 sys.path.insert(0, os.path.dirname(sys.argv[0]) + "/pyssh")    
 import pcucontrol.transports.pyssh as pyssh
-from monitor import config
-
 
 # Event class ID from pcu events
 #NODE_POWER_CONTROL = 3
@@ -35,7 +32,6 @@ from monitor import config
 #MONITOR_USER_ID = 11142
 
 import logging
-logger = logging.getLogger("monitor")
 verbose = 1
 #dryrun = 0;
 
@@ -135,7 +131,7 @@ class Transport:
                        transport.set_debuglevel(self.verbose)
                        if username is not None:
                                self.transport = transport
-                               self.transport.ifThenSend(prompt, username, ExceptionUsername)
+                               self.ifThenSend(prompt, username, ExceptionUsername)
 
                elif self.type == self.SSH:
                        if username is not None:
@@ -206,7 +202,7 @@ class Transport:
                                print r
 
                except urllib2.URLError,err:
-                       logger.info('Could not open http connection', err)
+                       print 'Could not open http connection', err
                        return "http transport error"
 
                return 0
@@ -255,17 +251,25 @@ class PCUControl(PCUModel,PCURecord):
        def reboot(self, node_port, dryrun):
 
                port_list = []
+               # There are two sources of potential ports.  Those that are open and
+               # those that are part of the PCU's supported_ports.  
+               #  I think we should start with supported_ports and then filter that
+               #  by the open ports.
+
+               port_list = self.supported_ports
+
                if hasattr(self, 'port_status') and self.port_status:
+                       # get out the open ports
                        port_list = filter(lambda x: self.port_status[x] == "open" , self.port_status.keys())
                        port_list = [ int(x) for x in port_list ]
+                       # take only the open ports that are supported_ports
+                       port_list = filter(lambda x: x in self.supported_ports, port_list)
                        if port_list == []:
-                               raise ExceptionPort("Unsupported Port: No transport from open ports")
-               else:
-                       port_list = self.supported_ports
+                               raise ExceptionPort("No Open Port: No transport from open ports")
 
                print port_list
 
-               ret = "could not run"
+               ret = "No implementation for open ports on selected PCU model"
                for port in port_list:
                        if port not in Transport.porttypemap:
                                continue
@@ -273,7 +277,9 @@ class PCUControl(PCUModel,PCURecord):
                        type = Transport.porttypemap[port]
                        self.transport = Transport(type, verbose)
 
+                       print "checking for run_%s" % type
                        if hasattr(self, "run_%s" % type):
+                               print "found run_%s" % type
                                fxn = getattr(self, "run_%s" % type)
                                ret = self.catcherror(fxn, node_port, dryrun)
                                if ret == 0: # NOTE: success!, so stop
@@ -316,14 +322,16 @@ class PCUControl(PCUModel,PCURecord):
                except urllib2.URLError, err:
                        return "URLError: " + str(err)
                except EOFError, err:
-                       if self.verbose:
-                               logger.debug("reboot: EOF")
-                               logger.debug(err)
                        self.transport.close()
                        import traceback
                        traceback.print_exc()
                        return "EOF connection reset" + str(err)
+               except Exception, err:
+                       from monitor.common import email_exception
+                       email_exception(self.host)
+                       raise Exception(err)
 
+from pcucontrol.util import command
 from pcucontrol.models import *
 
 def pcu_name(pcu):
@@ -334,73 +342,6 @@ def pcu_name(pcu):
        else:
                return None
 
-def get_pcu_values(pcu_id):
-       from monitor.database.info.model import FindbadPCURecord
-       print "pcuid: %s" % pcu_id
-       try:
-               pcurec = FindbadPCURecord.get_latest_by(plc_pcuid=pcu_id).first()
-               if pcurec:
-                       values = pcurec.to_dict()
-               else:
-                       values = None
-       except:
-               values = None
-
-       return values
-
-def reboot(nodename):
-       return reboot_policy(nodename, True, False)
-
-def reboot_str(nodename):
-       global verbose
-       continue_probe = True
-       dryrun=False
-
-       pcu = plc.getpcu(nodename)
-       if not pcu:
-               logger.debug("no pcu for %s" % nodename)
-               print "no pcu for %s" % nodename
-               return False # "%s has no pcu" % nodename
-
-       values = get_pcu_values(pcu['pcu_id'])
-       if values == None:
-               logger.debug("No values for pcu probe %s" % nodename)
-               print "No values for pcu probe %s" % nodename
-               return False #"no info for pcu_id %s" % pcu['pcu_id']
-       
-       # Try the PCU first
-       logger.debug("Trying PCU %s %s" % (pcu['hostname'], pcu['model']))
-
-       ret = reboot_test_new(nodename, values, verbose, dryrun)
-       return ret
-       
-def reboot_policy(nodename, continue_probe, dryrun):
-       global verbose
-
-       pcu = plc.getpcu(nodename)
-       if not pcu:
-               logger.debug("no pcu for %s" % nodename)
-               print "no pcu for %s" % nodename
-               return False # "%s has no pcu" % nodename
-
-       values = get_pcu_values(pcu['pcu_id'])
-       if values == None:
-               logger.debug("No values for pcu probe %s" % nodename)
-               print "No values for pcu probe %s" % nodename
-               return False #"no info for pcu_id %s" % pcu['pcu_id']
-       
-       # Try the PCU first
-       logger.debug("Trying PCU %s %s" % (pcu['hostname'], pcu['model']))
-
-       ret = reboot_test_new(nodename, values, verbose, dryrun)
-
-       if ret != 0:
-               print ret
-               return False
-       else:
-               print "return true"
-               return True
-
 class Unknown(PCUControl):
        supported_ports = [22,23,80,443,5869,9100,16992]
 
@@ -435,7 +376,7 @@ def model_to_object(modelname):
                print "UNKNOWN model %s"%modelname
                return Unknown
 
-def reboot_api(node, pcu): #, verbose, dryrun):
+def reboot_api(node, pcu):
        rb_ret = ""
 
        try:
@@ -452,19 +393,68 @@ def reboot_api(node, pcu): #, verbose, dryrun):
                        rb_ret =  "No modelname in PCU record."
                # TODO: how to handle the weird, georgetown pcus, the drac faults, and ilo faults
        except Exception, err:
-               rb_ret = str(err)
+               rb_ret = "Exception Model(%s): " % modelname 
+               rb_ret += str(err)
 
        return rb_ret
 
+def convert_oldmodelname_to_newmodelname(oldmodelname, pcu_id):
+       newmodelname = None
+       update = {      'AP79xx' : 'APCControl13p13',
+                               'Masterswitch' : 'APCControl13p13',
+                               'DS4-RPC' : 'BayTech',
+                               'IP-41x_IP-81x' : 'IPAL',
+                               'DRAC3' : 'DRAC',
+                               'DRAC4' : 'DRAC',
+                               'ePowerSwitch' : 'ePowerSwitchOld',
+                               'ilo2' : 'HPiLO',
+                               'ilo1' : 'HPiLO',
+                               'PM211-MIP' : 'PM211MIP',
+                               'AMT2.5' : 'IntelAMT',
+                               'AMT3.0' : 'IntelAMT',
+                               'WTI_IPS-4' : 'WTIIPS4',
+                               'unknown'  : 'ManualPCU',
+                               'DRAC5' : 'DRAC',
+                               'ipmi'  : 'OpenIPMI',
+                               'bbsemaverick' : 'BlackBoxPSMaverick',
+                               'manualadmin'  : 'ManualPCU',
+       }
+
+       if oldmodelname in update:
+               newmodelname = update[oldmodelname]
+       else:
+               newmodelname = oldmodelname
+
+       if pcu_id in [1102,1163,1055,1111,1231,1113,1127,1128,1148]:
+               newmodelname = 'APCControl12p3'
+       elif pcu_id in [1110,86]:
+               newmodelname = 'APCControl1p4'
+       elif pcu_id in [1221,1225,1220,1192]:
+               newmodelname = 'APCControl121p3'
+       elif pcu_id in [1173,1240,47,1363,1405,1401,1372,1371]:
+               newmodelname = 'APCControl121p1'
+       elif pcu_id in [1056,1237,1052,1209,1002,1008,1013,1022]:
+               newmodelname = 'BayTechCtrlC'
+       elif pcu_id in [93]:
+               newmodelname = 'BayTechRPC3NC'
+       elif pcu_id in [1057]:
+               newmodelname = 'BayTechCtrlCUnibe'
+       elif pcu_id in [1012]:
+               newmodelname = 'BayTechRPC16'
+       elif pcu_id in [1089, 1071, 1046, 1035, 1118]:
+               newmodelname = 'ePowerSwitchNew'
+
+       return newmodelname
+
 def reboot_test_new(nodename, values, verbose, dryrun):
        rb_ret = ""
        if 'plc_pcu_stats' in values:
                values.update(values['plc_pcu_stats'])
 
        try:
-               modelname = values['model']
+               modelname = convert_oldmodelname_to_newmodelname(values['model'], values['pcu_id'])
                if modelname:
-                       object = eval('%s(values, verbose, ["22", "23", "80", "443", "9100", "16992", "5869"])' % modelname)
+                       object = eval('%s(values, verbose)' % modelname)
                        rb_ret = object.reboot(values[nodename], dryrun)
                else:
                        rb_ret =  "Not_Run"
@@ -477,34 +467,7 @@ def reboot_test_new(nodename, values, verbose, dryrun):
        return rb_ret
 
 def main():
-       logger.setLevel(logging.DEBUG)
-       ch = logging.StreamHandler()
-       ch.setLevel(logging.DEBUG)
-       formatter = logging.Formatter('LOGGER - %(message)s')
-       ch.setFormatter(formatter)
-       logger.addHandler(ch)
-
-       try:
-               if "test" in sys.argv:
-                       dryrun = True
-               else:
-                       dryrun = False
-
-               for node in sys.argv[1:]:
-                       if node == "test": continue
-
-                       print "Rebooting %s" % node
-                       if reboot_policy(node, True, dryrun):
-                               print "success"
-                       else:
-                               print "failed"
-       except Exception, err:
-               import traceback; traceback.print_exc()
-               print err
+       print "this does not work."
 
 if __name__ == '__main__':
-       logger = logging.getLogger("monitor")
        main()
-       f = open("/tmp/rebootlog", 'a')
-       f.write("reboot %s\n" % sys.argv)
-       f.close()