.\" -*- nroff -*- .de IQ . br . ns . IP "\\$1" .. .TH ovs\-vswitchd 8 "June 2009" "Open vSwitch" "Open vSwitch Manual" .\" This program's name: .ds PN ovs\-vswitchd .\" SSL peer program's name: .ds SN ovs\-controller . .SH NAME ovs\-vswitchd \- Open vSwitch daemon . .SH SYNOPSIS \fBovs\-vswitchd \fR[\fIdatabase\fR] . .SH DESCRIPTION A daemon that manages and controls any number of Open vSwitch switches on the local machine. .PP The \fIdatabase\fR argument specifies how \fBovs\-vswitchd\fR connects to \fBovsdb\-server\fR. The default is \fBunix:@RUNDIR@/db.sock\fR. The following forms are accepted: .so ovsdb/remote-active.man .so ovsdb/remote-passive.man .PP \fBovs\-vswitchd\fR retrieves its configuration from \fIdatabase\fR at startup. It sets up Open vSwitch datapaths and then operates switching across each bridge described in its configuration files. As the database changes, \fBovs\-vswitchd\fR automatically updates its configuration to match. .PP Upon receipt of a SIGHUP signal, \fBovs\-vswitchd\fR reopens its log file, if one was specified on the command line. .PP \fBovs\-vswitchd\fR switches may be configured with any of the following features: . .IP \(bu L2 switching with MAC learning. . .IP \(bu NIC bonding with automatic fail-over and source MAC-based TX load balancing ("SLB"). . .IP \(bu 802.1Q VLAN support. . .IP \(bu Port mirroring, with optional VLAN tagging. . .IP \(bu NetFlow v5 flow logging. . .IP \(bu sFlow(R) monitoring. . .IP \(bu Connectivity to an external OpenFlow controller, such as NOX. . .PP Only a single instance of \fBovs\-vswitchd\fR is intended to run at a time. A single \fBovs\-vswitchd\fR can manage any number of switch instances, up to the maximum number of supported Open vSwitch datapaths. .PP \fBovs\-vswitchd\fR does all the necessary management of Open vSwitch datapaths itself. Thus, external tools, such \fBovs\-dpctl\fR(8), are not needed for managing datapaths in conjunction with \fBovs\-vswitchd\fR, and their use to modify datapaths when \fBovs\-vswitchd\fR is running can interfere with its operation. (\fBovs\-dpctl\fR may still be useful for diagnostics.) .PP An Open vSwitch datapath kernel module must be loaded for \fBovs\-vswitchd\fR to be useful. Please refer to the \fBINSTALL.Linux\fR file included in the Open vSwitch distribution for instructions on how to build and load the Open vSwitch kernel module. .PP .SH OPTIONS .IP "\fB\-\-mlockall\fR" Causes \fBovs\-vswitchd\fR to call the \fBmlockall()\fR function, to attempt to lock all of its process memory into physical RAM, preventing the kernel from paging any of its memory to disk. This helps to avoid networking interruptions due to system memory pressure. .IP Some systems do not support \fBmlockall()\fR at all, and other systems only allow privileged users, such as the superuser, to use it. \fBovs\-vswitchd\fR emits a log message if \fBmlockall()\fR is unavailable or unsuccessful. . .ds DD \ \fBovs\-vswitchd\fR detaches only after it has connected to the \ database, retrieved the initial configuration, and set up that \ configuration. .so lib/daemon.man .SS "Public Key Infrastructure Options" .so lib/ssl.man .so lib/ssl-bootstrap.man .so lib/vlog.man .so lib/common.man .so lib/leak-checker.man . .SH "RUNTIME MANAGEMENT COMMANDS" \fBovs\-appctl\fR(8) can send commands to a running \fBovs\-vswitchd\fR process. The currently supported commands are described below. The command descriptions assume an understanding of how to configure Open vSwitch. .SS "GENERAL COMMANDS" .IP "\fBexit\fR" Causes \fBovs\-vswitchd\fR to gracefully terminate. .IP "\fBcoverage/log\fR" Logs coverage counters at level warn. .IP "\fBqos/show\fR \fIinterface\fR" Queries the kernel for Quality of Service configuration and statistics associated with the given \fIinterface\fR. .IP "\fBcfm/show\fR [\fIinterface\fR]" Displays detailed information about Connectivity Fault Management configured on \fIinterface\fR. If \fIinterface\fR is not specified, then displays detailed information about all interfaces with CFM enabled. .IP "\fBcfm/set-fault\fR [\fIinterface\fR] \fIstatus\fR" Force the fault status of the CFM module on \fIinterface\fR (or all interfaces if none is given) to be \fIstatus\fR. \fIstatus\fR can be "true", "false", or "normal" which reverts to the standard behavior. .IP "\fBstp/tcn\fR [\fIbridge\fR]" Forces a topology change event on \fIbridge\fR if it's running STP. This may cause it to send Topology Change Notifications to its peers and flush its MAC table.. If no \fIbridge\fR is given, forces a topology change event on all bridges. .SS "BRIDGE COMMANDS" These commands manage bridges. .IP "\fBfdb/flush\fR [\fIbridge\fR]" Flushes \fIbridge\fR MAC address learning table, or all learning tables if no \fIbridge\fR is given. .IP "\fBfdb/show\fR \fIbridge\fR" Lists each MAC address/VLAN pair learned by the specified \fIbridge\fR, along with the port on which it was learned and the age of the entry, in seconds. .IP "\fBbridge/reconnect\fR [\fIbridge\fR]" Makes \fIbridge\fR drop all of its OpenFlow controller connections and reconnect. If \fIbridge\fR is not specified, then all bridges drop their controller connections and reconnect. .IP This command might be useful for debugging OpenFlow controller issues. . .IP "\fBbridge/dump\-flows\fR \fIbridge\fR" Lists all flows in \fIbridge\fR, including those normally hidden to commands such as \fBovs\-ofctl dump\-flows\fR. Flows set up by mechanisms such as in-band control and fail-open are hidden from the controller since it is not allowed to modify or override them. .SS "BOND COMMANDS" These commands manage bonded ports on an Open vSwitch's bridges. To understand some of these commands, it is important to understand a detail of the bonding implementation called ``source load balancing'' (SLB). Instead of directly assigning Ethernet source addresses to slaves, the bonding implementation computes a function that maps an 48-bit Ethernet source addresses into an 8-bit value (a ``MAC hash'' value). All of the Ethernet addresses that map to a single 8-bit value are then assigned to a single slave. .IP "\fBbond/list\fR" Lists all of the bonds, and their slaves, on each bridge. . .IP "\fBbond/show\fR \fIport\fR" Lists all of the bond-specific information about the given bonded \fIport\fR: updelay, downdelay, time until the next rebalance. Also lists information about each slave: whether it is enabled or disabled, the time to completion of an updelay or downdelay if one is in progress, whether it is the active slave, the MAC hashes assigned to the slave, and the MAC learning table entries that hash to each MAC. Any LACP information related to this bond may be found using the \fBlacp/show\fR command. .IP "\fBbond/migrate\fR \fIport\fR \fIhash\fR \fIslave\fR" Only valid for SLB bonds. Assigns a given MAC hash to a new slave. \fIport\fR specifies the bond port, \fIhash\fR the MAC hash to be migrated (as a decimal number between 0 and 255), and \fIslave\fR the new slave to be assigned. .IP The reassignment is not permanent: rebalancing or fail-over will cause the MAC hash to be shifted to a new slave in the usual manner. .IP A MAC hash cannot be migrated to a disabled slave. .IP "\fBbond/set\-active\-slave\fR \fIport\fR \fIslave\fR" Sets \fIslave\fR as the active slave on \fIport\fR. \fIslave\fR must currently be enabled. .IP The setting is not permanent: a new active slave will be selected if \fIslave\fR becomes disabled. .IP "\fBbond/enable\-slave\fR \fIport\fR \fIslave\fR" .IQ "\fBbond/disable\-slave\fR \fIport\fR \fIslave\fR" Enables (or disables) \fIslave\fR on the given bond \fIport\fR, skipping any updelay (or downdelay). .IP This setting is not permanent: it persists only until the carrier status of \fIslave\fR changes. .IP "\fBbond/hash\fR \fImac\fR [\fIvlan\fR] [\fIbasis\fR]" Returns the hash value which would be used for \fImac\fR with \fIvlan\fR and \fIbasis\fR if specified. . .IP "\fBlacp/show\fR [\fIport\fR]" Lists all of the LACP related information about the given \fIport\fR: active or passive, aggregation key, system id, and system priority. Also lists information about each slave: whether it is enabled or disabled, whether it is attached or detached, port id and priority, actor information, and partner information. If \fIport\fR is not specified, then displays detailed information about all interfaces with CFM enabled. . .so ofproto/ofproto-unixctl.man .so lib/vlog-unixctl.man .so lib/stress-unixctl.man .SH "SEE ALSO" .BR ovs\-appctl (8), .BR ovs\-brcompatd (8), .BR ovsdb\-server (1), \fBINSTALL.Linux\fR in the Open vSwitch distribution.