ofproto-dpif: Store patch port peer in struct ofport_dpif.
[sliver-openvswitch.git] / FAQ
1                  Open vSwitch <http://openvswitch.org>
2
3 Frequently Asked Questions
4 ==========================
5
6 General
7 -------
8
9 Q: What is Open vSwitch?
10
11 A: Open vSwitch is a production quality open source software switch
12    designed to be used as a vswitch in virtualized server
13    environments.  A vswitch forwards traffic between different VMs on
14    the same physical host and also forwards traffic between VMs and
15    the physical network.  Open vSwitch supports standard management
16    interfaces (e.g. sFlow, NetFlow, IPFIX, RSPAN, CLI), and is open to
17    programmatic extension and control using OpenFlow and the OVSDB
18    management protocol.
19
20    Open vSwitch as designed to be compatible with modern switching
21    chipsets.  This means that it can be ported to existing high-fanout
22    switches allowing the same flexible control of the physical
23    infrastructure as the virtual infrastructure.  It also means that
24    Open vSwitch will be able to take advantage of on-NIC switching
25    chipsets as their functionality matures.
26
27 Q: What virtualization platforms can use Open vSwitch?
28
29 A: Open vSwitch can currently run on any Linux-based virtualization
30    platform (kernel 2.6.18 and newer), including: KVM, VirtualBox, Xen,
31    Xen Cloud Platform, XenServer. As of Linux 3.3 it is part of the
32    mainline kernel.  The bulk of the code is written in platform-
33    independent C and is easily ported to other environments.  We welcome
34    inquires about integrating Open vSwitch with other virtualization
35    platforms.
36
37 Q: How can I try Open vSwitch?
38
39 A: The Open vSwitch source code can be built on a Linux system.  You can
40    build and experiment with Open vSwitch on any Linux machine.
41    Packages for various Linux distributions are available on many
42    platforms, including: Debian, Ubuntu, Fedora.
43
44    You may also download and run a virtualization platform that already
45    has Open vSwitch integrated.  For example, download a recent ISO for
46    XenServer or Xen Cloud Platform.  Be aware that the version
47    integrated with a particular platform may not be the most recent Open
48    vSwitch release.
49
50 Q: Does Open vSwitch only work on Linux?
51
52 A: No, Open vSwitch has been ported to a number of different operating
53    systems and hardware platforms.  Most of the development work occurs
54    on Linux, but the code should be portable to any POSIX system.  We've
55    seen Open vSwitch ported to a number of different platforms,
56    including FreeBSD, Windows, and even non-POSIX embedded systems.
57
58    By definition, the Open vSwitch Linux kernel module only works on
59    Linux and will provide the highest performance.  However, a userspace
60    datapath is available that should be very portable.
61
62 Q: What's involved with porting Open vSwitch to a new platform or
63    switching ASIC?
64
65 A: The PORTING document describes how one would go about porting Open
66    vSwitch to a new operating system or hardware platform.
67
68 Q: Why would I use Open vSwitch instead of the Linux bridge?
69
70 A: Open vSwitch is specially designed to make it easier to manage VM
71    network configuration and monitor state spread across many physical
72    hosts in dynamic virtualized environments.  Please see WHY-OVS for a
73    more detailed description of how Open vSwitch relates to the Linux
74    Bridge.
75
76 Q: How is Open vSwitch related to distributed virtual switches like the
77    VMware vNetwork distributed switch or the Cisco Nexus 1000V?
78
79 A: Distributed vswitch applications (e.g., VMware vNetwork distributed
80    switch, Cisco Nexus 1000V) provide a centralized way to configure and
81    monitor the network state of VMs that are spread across many physical
82    hosts.  Open vSwitch is not a distributed vswitch itself, rather it
83    runs on each physical host and supports remote management in a way
84    that makes it easier for developers of virtualization/cloud
85    management platforms to offer distributed vswitch capabilities.
86
87    To aid in distribution, Open vSwitch provides two open protocols that
88    are specially designed for remote management in virtualized network
89    environments: OpenFlow, which exposes flow-based forwarding state,
90    and the OVSDB management protocol, which exposes switch port state.
91    In addition to the switch implementation itself, Open vSwitch
92    includes tools (ovs-controller, ovs-ofctl, ovs-vsctl) that developers
93    can script and extend to provide distributed vswitch capabilities
94    that are closely integrated with their virtualization management
95    platform.
96
97 Q: Why doesn't Open vSwitch support distribution?
98
99 A: Open vSwitch is intended to be a useful component for building
100    flexible network infrastructure. There are many different approaches
101    to distribution which balance trade-offs between simplicity,
102    scalability, hardware compatibility, convergence times, logical
103    forwarding model, etc. The goal of Open vSwitch is to be able to
104    support all as a primitive building block rather than choose a
105    particular point in the distributed design space.
106
107 Q: How can I contribute to the Open vSwitch Community?
108
109 A: You can start by joining the mailing lists and helping to answer
110    questions.  You can also suggest improvements to documentation.  If
111    you have a feature or bug you would like to work on, send a mail to
112    one of the mailing lists:
113
114        http://openvswitch.org/mlists/
115
116
117 Releases
118 --------
119
120 Q: What does it mean for an Open vSwitch release to be LTS (long-term
121    support)?
122
123 A: All official releases have been through a comprehensive testing
124    process and are suitable for production use.  Planned releases will
125    occur several times a year.  If a significant bug is identified in an
126    LTS release, we will provide an updated release that includes the
127    fix.  Releases that are not LTS may not be fixed and may just be
128    supplanted by the next major release.  The current LTS release is
129    1.9.x.
130
131 Q: What Linux kernel versions does each Open vSwitch release work with?
132
133 A: The following table lists the Linux kernel versions against which the
134    given versions of the Open vSwitch kernel module will successfully
135    build.  The Linux kernel versions are upstream kernel versions, so
136    Linux kernels modified from the upstream sources may not build in
137    some cases even if they are based on a supported version.  This is
138    most notably true of Red Hat Enterprise Linux (RHEL) kernels, which
139    are extensively modified from upstream.
140
141    Open vSwitch   Linux kernel
142    ------------   -------------
143        1.4.x      2.6.18 to 3.2
144        1.5.x      2.6.18 to 3.2
145        1.6.x      2.6.18 to 3.2
146        1.7.x      2.6.18 to 3.3
147        1.8.x      2.6.18 to 3.4
148        1.9.x      2.6.18 to 3.8
149
150    Open vSwitch userspace should also work with the Linux kernel module
151    built into Linux 3.3 and later.
152
153    Open vSwitch userspace is not sensitive to the Linux kernel version.
154    It should build against almost any kernel, certainly against 2.6.18
155    and later.
156
157 Q: What Linux kernel versions does IPFIX flow monitoring work with?
158
159 A: IPFIX flow monitoring requires the Linux kernel module from Open
160    vSwitch version 1.10.90 or later.
161
162 Q: Should userspace or kernel be upgraded first to minimize downtime?
163
164    In general, the Open vSwitch userspace should be used with the
165    kernel version included in the same release or with the version
166    from upstream Linux.  However, when upgrading between two releases
167    of Open vSwitch it is best to migrate userspace first to reduce
168    the possbility of incompatibilities.
169
170 Q: What features are not available in the Open vSwitch kernel datapath
171    that ships as part of the upstream Linux kernel?
172
173 A: The kernel module in upstream Linux 3.3 and later does not include
174    tunnel virtual ports, that is, interfaces with type "gre",
175    "ipsec_gre", "gre64", "ipsec_gre64", "vxlan", or "lisp".  It is
176    possible to create tunnels in Linux and attach them to Open vSwitch
177    as system devices.  However, they cannot be dynamically created
178    through the OVSDB protocol or set the tunnel ids as a flow action.
179
180    Work is in progress in adding tunnel virtual ports to the upstream
181    Linux version of the Open vSwitch kernel module.  For now, if you
182    need these features, use the kernel module from the Open vSwitch
183    distribution instead of the upstream Linux kernel module.
184
185    The upstream kernel module does not include patch ports, but this
186    only matters for Open vSwitch 1.9 and earlier, because Open vSwitch
187    1.10 and later implement patch ports without using this kernel
188    feature.
189
190 Q: What features are not available when using the userspace datapath?
191
192 A: Tunnel virtual ports are not supported, as described in the
193    previous answer.  It is also not possible to use queue-related
194    actions.  On Linux kernels before 2.6.39, maximum-sized VLAN packets
195    may not be transmitted.
196
197
198 Terminology
199 -----------
200
201 Q: I thought Open vSwitch was a virtual Ethernet switch, but the
202    documentation keeps talking about bridges.  What's a bridge?
203
204 A: In networking, the terms "bridge" and "switch" are synonyms.  Open
205    vSwitch implements an Ethernet switch, which means that it is also
206    an Ethernet bridge.
207
208 Q: What's a VLAN?
209
210 A: See the "VLAN" section below.
211
212
213 Basic Configuration
214 -------------------
215
216 Q: How do I configure a port as an access port?
217
218 A: Add "tag=VLAN" to your "ovs-vsctl add-port" command.  For example,
219    the following commands configure br0 with eth0 as a trunk port (the
220    default) and tap0 as an access port for VLAN 9:
221
222        ovs-vsctl add-br br0
223        ovs-vsctl add-port br0 eth0
224        ovs-vsctl add-port br0 tap0 tag=9
225
226    If you want to configure an already added port as an access port,
227    use "ovs-vsctl set", e.g.:
228
229        ovs-vsctl set port tap0 tag=9
230
231 Q: How do I configure a port as a SPAN port, that is, enable mirroring
232    of all traffic to that port?
233
234 A: The following commands configure br0 with eth0 and tap0 as trunk
235    ports.  All traffic coming in or going out on eth0 or tap0 is also
236    mirrored to tap1; any traffic arriving on tap1 is dropped:
237
238        ovs-vsctl add-br br0
239        ovs-vsctl add-port br0 eth0
240        ovs-vsctl add-port br0 tap0
241        ovs-vsctl add-port br0 tap1 \
242            -- --id=@p get port tap1 \
243            -- --id=@m create mirror name=m0 select-all=true output-port=@p \
244            -- set bridge br0 mirrors=@m
245
246    To later disable mirroring, run:
247
248        ovs-vsctl clear bridge br0 mirrors
249
250 Q: How do I configure a VLAN as an RSPAN VLAN, that is, enable
251    mirroring of all traffic to that VLAN?
252
253 A: The following commands configure br0 with eth0 as a trunk port and
254    tap0 as an access port for VLAN 10.  All traffic coming in or going
255    out on tap0, as well as traffic coming in or going out on eth0 in
256    VLAN 10, is also mirrored to VLAN 15 on eth0.  The original tag for
257    VLAN 10, in cases where one is present, is dropped as part of
258    mirroring:
259
260        ovs-vsctl add-br br0
261        ovs-vsctl add-port br0 eth0
262        ovs-vsctl add-port br0 tap0 tag=10
263        ovs-vsctl \
264            -- --id=@m create mirror name=m0 select-all=true select-vlan=10 \
265                                     output-vlan=15 \
266            -- set bridge br0 mirrors=@m
267
268    To later disable mirroring, run:
269
270        ovs-vsctl clear bridge br0 mirrors
271
272    Mirroring to a VLAN can disrupt a network that contains unmanaged
273    switches.  See ovs-vswitchd.conf.db(5) for details.  Mirroring to a
274    GRE tunnel has fewer caveats than mirroring to a VLAN and should
275    generally be preferred.
276
277 Q: Can I mirror more than one input VLAN to an RSPAN VLAN?
278
279 A: Yes, but mirroring to a VLAN strips the original VLAN tag in favor
280    of the specified output-vlan.  This loss of information may make
281    the mirrored traffic too hard to interpret.
282
283    To mirror multiple VLANs, use the commands above, but specify a
284    comma-separated list of VLANs as the value for select-vlan.  To
285    mirror every VLAN, use the commands above, but omit select-vlan and
286    its value entirely.
287
288    When a packet arrives on a VLAN that is used as a mirror output
289    VLAN, the mirror is disregarded.  Instead, in standalone mode, OVS
290    floods the packet across all the ports for which the mirror output
291    VLAN is configured.  (If an OpenFlow controller is in use, then it
292    can override this behavior through the flow table.)  If OVS is used
293    as an intermediate switch, rather than an edge switch, this ensures
294    that the RSPAN traffic is distributed through the network.
295
296    Mirroring to a VLAN can disrupt a network that contains unmanaged
297    switches.  See ovs-vswitchd.conf.db(5) for details.  Mirroring to a
298    GRE tunnel has fewer caveats than mirroring to a VLAN and should
299    generally be preferred.
300
301 Q: How do I configure mirroring of all traffic to a GRE tunnel?
302
303 A: The following commands configure br0 with eth0 and tap0 as trunk
304    ports.  All traffic coming in or going out on eth0 or tap0 is also
305    mirrored to gre0, a GRE tunnel to the remote host 192.168.1.10; any
306    traffic arriving on gre0 is dropped:
307
308        ovs-vsctl add-br br0
309        ovs-vsctl add-port br0 eth0
310        ovs-vsctl add-port br0 tap0
311        ovs-vsctl add-port br0 gre0 \
312            -- set interface gre0 type=gre options:remote_ip=192.168.1.10 \
313            -- --id=@p get port gre0 \
314            -- --id=@m create mirror name=m0 select-all=true output-port=@p \
315            -- set bridge br0 mirrors=@m
316
317    To later disable mirroring and destroy the GRE tunnel:
318
319        ovs-vsctl clear bridge br0 mirrors
320        ovs-vcstl del-port br0 gre0
321
322 Q: Does Open vSwitch support ERSPAN?
323
324 A: No.  ERSPAN is an undocumented proprietary protocol.  As an
325    alternative, Open vSwitch supports mirroring to a GRE tunnel (see
326    above).
327
328 Q: How do I connect two bridges?
329
330 A: First, why do you want to do this?  Two connected bridges are not
331    much different from a single bridge, so you might as well just have
332    a single bridge with all your ports on it.
333
334    If you still want to connect two bridges, you can use a pair of
335    patch ports.  The following example creates bridges br0 and br1,
336    adds eth0 and tap0 to br0, adds tap1 to br1, and then connects br0
337    and br1 with a pair of patch ports.
338
339        ovs-vsctl add-br br0
340        ovs-vsctl add-port br0 eth0
341        ovs-vsctl add-port br0 tap0
342        ovs-vsctl add-br br1
343        ovs-vsctl add-port br1 tap1
344        ovs-vsctl \
345            -- add-port br0 patch0 \
346            -- set interface patch0 type=patch options:peer=patch1 \
347            -- add-port br1 patch1 \
348            -- set interface patch1 type=patch options:peer=patch0
349
350    Bridges connected with patch ports are much like a single bridge.
351    For instance, if the example above also added eth1 to br1, and both
352    eth0 and eth1 happened to be connected to the same next-hop switch,
353    then you could loop your network just as you would if you added
354    eth0 and eth1 to the same bridge (see the "Configuration Problems"
355    section below for more information).
356
357    If you are using Open vSwitch 1.9 or an earlier version, then you
358    need to be using the kernel module bundled with Open vSwitch rather
359    than the one that is integrated into Linux 3.3 and later, because
360    Open vSwitch 1.9 and earlier versions need kernel support for patch
361    ports.  This also means that in Open vSwitch 1.9 and earlier, patch
362    ports will not work with the userspace datapath, only with the
363    kernel module.
364
365 Q: Why are there so many different ways to dump flows?
366
367 A: Open vSwitch uses different kinds of flows for different purposes:
368
369       - OpenFlow flows are the most important kind of flow.  OpenFlow
370         controllers use these flows to define a switch's policy.
371         OpenFlow flows support wildcards, priorities, and multiple
372         tables.
373
374         When in-band control is in use, Open vSwitch sets up a few
375         "hidden" flows, with priority higher than a controller or the
376         user can configure, that are not visible via OpenFlow.  (See
377         the "Controller" section of the FAQ for more information
378         about hidden flows.)
379
380       - The Open vSwitch software switch implementation uses a second
381         kind of flow internally.  These flows, called "exact-match"
382         or "datapath" or "kernel" flows, do not support wildcards or
383         priorities and comprise only a single table, which makes them
384         suitable for caching.   OpenFlow flows and exact-match flows
385         also support different actions and number ports differently.
386
387         Exact-match flows are an implementation detail that is
388         subject to change in future versions of Open vSwitch.  Even
389         with the current version of Open vSwitch, hardware switch
390         implementations do not necessarily use exact-match flows.
391
392   Each of the commands for dumping flows has a different purpose:
393
394       - "ovs-ofctl dump-flows <br>" dumps OpenFlow flows, excluding
395         hidden flows.  This is the most commonly useful form of flow
396         dump.  (Unlike the other commands, this should work with any
397         OpenFlow switch, not just Open vSwitch.)
398
399       - "ovs-appctl bridge/dump-flows <br>" dumps OpenFlow flows,
400         including hidden flows.  This is occasionally useful for
401         troubleshooting suspected issues with in-band control.
402
403       - "ovs-dpctl dump-flows [dp]" dumps the exact-match flow table
404         entries for a Linux kernel-based datapath.  In Open vSwitch
405         1.10 and later, ovs-vswitchd merges multiple switches into a
406         single datapath, so it will show all the flows on all your
407         kernel-based switches.  This command can occasionally be
408         useful for debugging.
409
410       - "ovs-appctl dpif/dump-flows <br>", new in Open vSwitch 1.10,
411         dumps exact-match flows for only the specified bridge,
412         regardless of the type.
413
414
415 Configuration Problems
416 ----------------------
417
418 Q: I created a bridge and added my Ethernet port to it, using commands
419    like these:
420
421        ovs-vsctl add-br br0
422        ovs-vsctl add-port br0 eth0
423
424    and as soon as I ran the "add-port" command I lost all connectivity
425    through eth0.  Help!
426
427 A: A physical Ethernet device that is part of an Open vSwitch bridge
428    should not have an IP address.  If one does, then that IP address
429    will not be fully functional.
430
431    You can restore functionality by moving the IP address to an Open
432    vSwitch "internal" device, such as the network device named after
433    the bridge itself.  For example, assuming that eth0's IP address is
434    192.168.128.5, you could run the commands below to fix up the
435    situation:
436
437        ifconfig eth0 0.0.0.0
438        ifconfig br0 192.168.128.5
439
440    (If your only connection to the machine running OVS is through the
441    IP address in question, then you would want to run all of these
442    commands on a single command line, or put them into a script.)  If
443    there were any additional routes assigned to eth0, then you would
444    also want to use commands to adjust these routes to go through br0.
445
446    If you use DHCP to obtain an IP address, then you should kill the
447    DHCP client that was listening on the physical Ethernet interface
448    (e.g. eth0) and start one listening on the internal interface
449    (e.g. br0).  You might still need to manually clear the IP address
450    from the physical interface (e.g. with "ifconfig eth0 0.0.0.0").
451
452    There is no compelling reason why Open vSwitch must work this way.
453    However, this is the way that the Linux kernel bridge module has
454    always worked, so it's a model that those accustomed to Linux
455    bridging are already used to.  Also, the model that most people
456    expect is not implementable without kernel changes on all the
457    versions of Linux that Open vSwitch supports.
458
459    By the way, this issue is not specific to physical Ethernet
460    devices.  It applies to all network devices except Open vswitch
461    "internal" devices.
462
463 Q: I created a bridge and added a couple of Ethernet ports to it,
464    using commands like these:
465
466        ovs-vsctl add-br br0
467        ovs-vsctl add-port br0 eth0
468        ovs-vsctl add-port br0 eth1
469
470    and now my network seems to have melted: connectivity is unreliable
471    (even connectivity that doesn't go through Open vSwitch), all the
472    LEDs on my physical switches are blinking, wireshark shows
473    duplicated packets, and CPU usage is very high.
474
475 A: More than likely, you've looped your network.  Probably, eth0 and
476    eth1 are connected to the same physical Ethernet switch.  This
477    yields a scenario where OVS receives a broadcast packet on eth0 and
478    sends it out on eth1, then the physical switch connected to eth1
479    sends the packet back on eth0, and so on forever.  More complicated
480    scenarios, involving a loop through multiple switches, are possible
481    too.
482
483    The solution depends on what you are trying to do:
484
485        - If you added eth0 and eth1 to get higher bandwidth or higher
486          reliability between OVS and your physical Ethernet switch,
487          use a bond.  The following commands create br0 and then add
488          eth0 and eth1 as a bond:
489
490              ovs-vsctl add-br br0
491              ovs-vsctl add-bond br0 bond0 eth0 eth1
492
493          Bonds have tons of configuration options.  Please read the
494          documentation on the Port table in ovs-vswitchd.conf.db(5)
495          for all the details.
496
497        - Perhaps you don't actually need eth0 and eth1 to be on the
498          same bridge.  For example, if you simply want to be able to
499          connect each of them to virtual machines, then you can put
500          each of them on a bridge of its own:
501
502              ovs-vsctl add-br br0
503              ovs-vsctl add-port br0 eth0
504
505              ovs-vsctl add-br br1
506              ovs-vsctl add-port br1 eth1
507
508          and then connect VMs to br0 and br1.  (A potential
509          disadvantage is that traffic cannot directly pass between br0
510          and br1.  Instead, it will go out eth0 and come back in eth1,
511          or vice versa.)
512
513        - If you have a redundant or complex network topology and you
514          want to prevent loops, turn on spanning tree protocol (STP).
515          The following commands create br0, enable STP, and add eth0
516          and eth1 to the bridge.  The order is important because you
517          don't want have to have a loop in your network even
518          transiently:
519
520              ovs-vsctl add-br br0
521              ovs-vsctl set bridge br0 stp_enable=true
522              ovs-vsctl add-port br0 eth0
523              ovs-vsctl add-port br0 eth1
524
525          The Open vSwitch implementation of STP is not well tested.
526          Please report any bugs you observe, but if you'd rather avoid
527          acting as a beta tester then another option might be your
528          best shot.
529
530 Q: I can't seem to use Open vSwitch in a wireless network.
531
532 A: Wireless base stations generally only allow packets with the source
533    MAC address of NIC that completed the initial handshake.
534    Therefore, without MAC rewriting, only a single device can
535    communicate over a single wireless link.
536
537    This isn't specific to Open vSwitch, it's enforced by the access
538    point, so the same problems will show up with the Linux bridge or
539    any other way to do bridging.
540
541 Q: I can't seem to add my PPP interface to an Open vSwitch bridge.
542
543 A: PPP most commonly carries IP packets, but Open vSwitch works only
544    with Ethernet frames.  The correct way to interface PPP to an
545    Ethernet network is usually to use routing instead of switching.
546
547 Q: Is there any documentation on the database tables and fields?
548
549 A: Yes.  ovs-vswitchd.conf.db(5) is a comprehensive reference.
550
551 Q: When I run ovs-dpctl I no longer see the bridges I created.  Instead,
552    I only see a datapath called "ovs-system".  How can I see datapath
553    information about a particular bridge?
554
555 A: In version 1.9.0, OVS switched to using a single datapath that is
556    shared by all bridges of that type.  The "ovs-appctl dpif/*"
557    commands provide similar functionality that is scoped by the bridge.
558
559
560 Quality of Service (QoS)
561 ------------------------
562
563 Q: How do I configure Quality of Service (QoS)?
564
565 A: Suppose that you want to set up bridge br0 connected to physical
566    Ethernet port eth0 (a 1 Gbps device) and virtual machine interfaces
567    vif1.0 and vif2.0, and that you want to limit traffic from vif1.0
568    to eth0 to 10 Mbps and from vif2.0 to eth0 to 20 Mbps.  Then, you
569    could configure the bridge this way:
570
571        ovs-vsctl -- \
572            add-br br0 -- \
573            add-port br0 eth0 -- \
574            add-port br0 vif1.0 -- set interface vif1.0 ofport_request=5 -- \
575            add-port br0 vif2.0 -- set interface vif2.0 ofport_request=6 -- \
576            set port eth0 qos=@newqos -- \
577            --id=@newqos create qos type=linux-htb \
578                other-config:max-rate=1000000000 \
579                queues:123=@vif10queue \
580                queues:234=@vif20queue -- \
581            --id=@vif10queue create queue other-config:max-rate=10000000 -- \
582            --id=@vif20queue create queue other-config:max-rate=20000000
583
584    At this point, bridge br0 is configured with the ports and eth0 is
585    configured with the queues that you need for QoS, but nothing is
586    actually directing packets from vif1.0 or vif2.0 to the queues that
587    we have set up for them.  That means that all of the packets to
588    eth0 are going to the "default queue", which is not what we want.
589
590    We use OpenFlow to direct packets from vif1.0 and vif2.0 to the
591    queues reserved for them:
592
593        ovs-ofctl add-flow br0 in_port=5,actions=set_queue:123,normal
594        ovs-ofctl add-flow br0 in_port=6,actions=set_queue:234,normal
595
596    Each of the above flows matches on the input port, sets up the
597    appropriate queue (123 for vif1.0, 234 for vif2.0), and then
598    executes the "normal" action, which performs the same switching
599    that Open vSwitch would have done without any OpenFlow flows being
600    present.  (We know that vif1.0 and vif2.0 have OpenFlow port
601    numbers 5 and 6, respectively, because we set their ofport_request
602    columns above.  If we had not done that, then we would have needed
603    to find out their port numbers before setting up these flows.)
604
605    Now traffic going from vif1.0 or vif2.0 to eth0 should be
606    rate-limited.
607
608    By the way, if you delete the bridge created by the above commands,
609    with:
610
611        ovs-vsctl del-br br0
612
613    then that will leave one unreferenced QoS record and two
614    unreferenced Queue records in the Open vSwich database.  One way to
615    clear them out, assuming you don't have other QoS or Queue records
616    that you want to keep, is:
617
618        ovs-vsctl -- --all destroy QoS -- --all destroy Queue
619
620    If you do want to keep some QoS or Queue records, or the Open
621    vSwitch you are using is older than version 1.8 (which added the
622    --all option), then you will have to destroy QoS and Queue records
623    individually.
624
625 Q: I configured Quality of Service (QoS) in my OpenFlow network by
626    adding records to the QoS and Queue table, but the results aren't
627    what I expect.
628
629 A: Did you install OpenFlow flows that use your queues?  This is the
630    primary way to tell Open vSwitch which queues you want to use.  If
631    you don't do this, then the default queue will be used, which will
632    probably not have the effect you want.
633
634    Refer to the previous question for an example.
635
636 Q: I configured QoS, correctly, but my measurements show that it isn't
637    working as well as I expect.
638
639 A: With the Linux kernel, the Open vSwitch implementation of QoS has
640    two aspects:
641
642        - Open vSwitch configures a subset of Linux kernel QoS
643          features, according to what is in OVSDB.  It is possible that
644          this code has bugs.  If you believe that this is so, then you
645          can configure the Linux traffic control (QoS) stack directly
646          with the "tc" program.  If you get better results that way,
647          you can send a detailed bug report to bugs@openvswitch.org.
648
649          It is certain that Open vSwitch cannot configure every Linux
650          kernel QoS feature.  If you need some feature that OVS cannot
651          configure, then you can also use "tc" directly (or add that
652          feature to OVS).
653
654        - The Open vSwitch implementation of OpenFlow allows flows to
655          be directed to particular queues.  This is pretty simple and
656          unlikely to have serious bugs at this point.
657
658    However, most problems with QoS on Linux are not bugs in Open
659    vSwitch at all.  They tend to be either configuration errors
660    (please see the earlier questions in this section) or issues with
661    the traffic control (QoS) stack in Linux.  The Open vSwitch
662    developers are not experts on Linux traffic control.  We suggest
663    that, if you believe you are encountering a problem with Linux
664    traffic control, that you consult the tc manpages (e.g. tc(8),
665    tc-htb(8), tc-hfsc(8)), web resources (e.g. http://lartc.org/), or
666    mailing lists (e.g. http://vger.kernel.org/vger-lists.html#netdev).
667
668
669 VLANs
670 -----
671
672 Q: What's a VLAN?
673
674 A: At the simplest level, a VLAN (short for "virtual LAN") is a way to
675    partition a single switch into multiple switches.  Suppose, for
676    example, that you have two groups of machines, group A and group B.
677    You want the machines in group A to be able to talk to each other,
678    and you want the machine in group B to be able to talk to each
679    other, but you don't want the machines in group A to be able to
680    talk to the machines in group B.  You can do this with two
681    switches, by plugging the machines in group A into one switch and
682    the machines in group B into the other switch.
683
684    If you only have one switch, then you can use VLANs to do the same
685    thing, by configuring the ports for machines in group A as VLAN
686    "access ports" for one VLAN and the ports for group B as "access
687    ports" for a different VLAN.  The switch will only forward packets
688    between ports that are assigned to the same VLAN, so this
689    effectively subdivides your single switch into two independent
690    switches, one for each group of machines.
691
692    So far we haven't said anything about VLAN headers.  With access
693    ports, like we've described so far, no VLAN header is present in
694    the Ethernet frame.  This means that the machines (or switches)
695    connected to access ports need not be aware that VLANs are
696    involved, just like in the case where we use two different physical
697    switches.
698
699    Now suppose that you have a whole bunch of switches in your
700    network, instead of just one, and that some machines in group A are
701    connected directly to both switches 1 and 2.  To allow these
702    machines to talk to each other, you could add an access port for
703    group A's VLAN to switch 1 and another to switch 2, and then
704    connect an Ethernet cable between those ports.  That works fine,
705    but it doesn't scale well as the number of switches and the number
706    of VLANs increases, because you use up a lot of valuable switch
707    ports just connecting together your VLANs.
708
709    This is where VLAN headers come in.  Instead of using one cable and
710    two ports per VLAN to connect a pair of switches, we configure a
711    port on each switch as a VLAN "trunk port".  Packets sent and
712    received on a trunk port carry a VLAN header that says what VLAN
713    the packet belongs to, so that only two ports total are required to
714    connect the switches, regardless of the number of VLANs in use.
715    Normally, only switches (either physical or virtual) are connected
716    to a trunk port, not individual hosts, because individual hosts
717    don't expect to see a VLAN header in the traffic that they receive.
718
719    None of the above discussion says anything about particular VLAN
720    numbers.  This is because VLAN numbers are completely arbitrary.
721    One must only ensure that a given VLAN is numbered consistently
722    throughout a network and that different VLANs are given different
723    numbers.  (That said, VLAN 0 is usually synonymous with a packet
724    that has no VLAN header, and VLAN 4095 is reserved.)
725
726 Q: VLANs don't work.
727
728 A: Many drivers in Linux kernels before version 3.3 had VLAN-related
729    bugs.  If you are having problems with VLANs that you suspect to be
730    driver related, then you have several options:
731
732        - Upgrade to Linux 3.3 or later.
733
734        - Build and install a fixed version of the particular driver
735          that is causing trouble, if one is available.
736
737        - Use a NIC whose driver does not have VLAN problems.
738
739        - Use "VLAN splinters", a feature in Open vSwitch 1.4 and later
740          that works around bugs in kernel drivers.  To enable VLAN
741          splinters on interface eth0, use the command:
742
743            ovs-vsctl set interface eth0 other-config:enable-vlan-splinters=true
744
745          For VLAN splinters to be effective, Open vSwitch must know
746          which VLANs are in use.  See the "VLAN splinters" section in
747          the Interface table in ovs-vswitchd.conf.db(5) for details on
748          how Open vSwitch infers in-use VLANs.
749
750          VLAN splinters increase memory use and reduce performance, so
751          use them only if needed.
752
753        - Apply the "vlan workaround" patch from the XenServer kernel
754          patch queue, build Open vSwitch against this patched kernel,
755          and then use ovs-vlan-bug-workaround(8) to enable the VLAN
756          workaround for each interface whose driver is buggy.
757
758          (This is a nontrivial exercise, so this option is included
759          only for completeness.)
760
761    It is not always easy to tell whether a Linux kernel driver has
762    buggy VLAN support.  The ovs-vlan-test(8) and ovs-test(8) utilities
763    can help you test.  See their manpages for details.  Of the two
764    utilities, ovs-test(8) is newer and more thorough, but
765    ovs-vlan-test(8) may be easier to use.
766
767 Q: VLANs still don't work.  I've tested the driver so I know that it's OK.
768
769 A: Do you have VLANs enabled on the physical switch that OVS is
770    attached to?  Make sure that the port is configured to trunk the
771    VLAN or VLANs that you are using with OVS.
772
773 Q: Outgoing VLAN-tagged traffic goes through OVS to my physical switch
774    and to its destination host, but OVS seems to drop incoming return
775    traffic.
776
777 A: It's possible that you have the VLAN configured on your physical
778    switch as the "native" VLAN.  In this mode, the switch treats
779    incoming packets either tagged with the native VLAN or untagged as
780    part of the native VLAN.  It may also send outgoing packets in the
781    native VLAN without a VLAN tag.
782
783    If this is the case, you have two choices:
784
785        - Change the physical switch port configuration to tag packets
786          it forwards to OVS with the native VLAN instead of forwarding
787          them untagged.
788
789        - Change the OVS configuration for the physical port to a
790          native VLAN mode.  For example, the following sets up a
791          bridge with port eth0 in "native-tagged" mode in VLAN 9:
792
793              ovs-vsctl add-br br0
794              ovs-vsctl add-port br0 eth0 tag=9 vlan_mode=native-tagged
795
796          In this situation, "native-untagged" mode will probably work
797          equally well.  Refer to the documentation for the Port table
798          in ovs-vswitchd.conf.db(5) for more information.
799
800 Q: I added a pair of VMs on different VLANs, like this:
801
802        ovs-vsctl add-br br0
803        ovs-vsctl add-port br0 eth0
804        ovs-vsctl add-port br0 tap0 tag=9
805        ovs-vsctl add-port br0 tap1 tag=10
806
807     but the VMs can't access each other, the external network, or the
808     Internet.
809
810 A: It is to be expected that the VMs can't access each other.  VLANs
811    are a means to partition a network.  When you configured tap0 and
812    tap1 as access ports for different VLANs, you indicated that they
813    should be isolated from each other.
814
815    As for the external network and the Internet, it seems likely that
816    the machines you are trying to access are not on VLAN 9 (or 10) and
817    that the Internet is not available on VLAN 9 (or 10).
818
819 Q: I added a pair of VMs on the same VLAN, like this:
820
821        ovs-vsctl add-br br0
822        ovs-vsctl add-port br0 eth0
823        ovs-vsctl add-port br0 tap0 tag=9
824        ovs-vsctl add-port br0 tap1 tag=9
825
826     The VMs can access each other, but not the external network or the
827     Internet.
828
829 A: It seems likely that the machines you are trying to access in the
830    external network are not on VLAN 9 and that the Internet is not
831    available on VLAN 9.  Also, ensure VLAN 9 is set up as an allowed
832    trunk VLAN on the upstream switch port to which eth0 is connected.
833
834 Q: Can I configure an IP address on a VLAN?
835
836 A: Yes.  Use an "internal port" configured as an access port.  For
837    example, the following configures IP address 192.168.0.7 on VLAN 9.
838    That is, OVS will forward packets from eth0 to 192.168.0.7 only if
839    they have an 802.1Q header with VLAN 9.  Conversely, traffic
840    forwarded from 192.168.0.7 to eth0 will be tagged with an 802.1Q
841    header with VLAN 9:
842
843        ovs-vsctl add-br br0
844        ovs-vsctl add-port br0 eth0
845        ovs-vsctl add-port br0 vlan9 tag=9 -- set interface vlan9 type=internal
846        ifconfig vlan9 192.168.0.7
847
848 Q: My OpenFlow controller doesn't see the VLANs that I expect.
849
850 A: The configuration for VLANs in the Open vSwitch database (e.g. via
851    ovs-vsctl) only affects traffic that goes through Open vSwitch's
852    implementation of the OpenFlow "normal switching" action.  By
853    default, when Open vSwitch isn't connected to a controller and
854    nothing has been manually configured in the flow table, all traffic
855    goes through the "normal switching" action.  But, if you set up
856    OpenFlow flows on your own, through a controller or using ovs-ofctl
857    or through other means, then you have to implement VLAN handling
858    yourself.
859
860    You can use "normal switching" as a component of your OpenFlow
861    actions, e.g. by putting "normal" into the lists of actions on
862    ovs-ofctl or by outputting to OFPP_NORMAL from an OpenFlow
863    controller.  In situations where this is not suitable, you can
864    implement VLAN handling yourself, e.g.:
865
866        - If a packet comes in on an access port, and the flow table
867          needs to send it out on a trunk port, then the flow can add
868          the appropriate VLAN tag with the "mod_vlan_vid" action.
869
870        - If a packet comes in on a trunk port, and the flow table
871          needs to send it out on an access port, then the flow can
872          strip the VLAN tag with the "strip_vlan" action.
873
874 Q: I configured ports on a bridge as access ports with different VLAN
875    tags, like this:
876
877        ovs-vsctl add-br br0
878        ovs-vsctl set-controller br0 tcp:192.168.0.10:6633
879        ovs-vsctl add-port br0 eth0
880        ovs-vsctl add-port br0 tap0 tag=9
881        ovs-vsctl add-port br0 tap1 tag=10
882
883    but the VMs running behind tap0 and tap1 can still communicate,
884    that is, they are not isolated from each other even though they are
885    on different VLANs.
886
887 A: Do you have a controller configured on br0 (as the commands above
888    do)?  If so, then this is a variant on the previous question, "My
889    OpenFlow controller doesn't see the VLANs that I expect," and you
890    can refer to the answer there for more information.
891
892
893 VXLANs
894 -----
895
896 Q: What's a VXLAN?
897
898 A: VXLAN stands for Virtual eXtensible Local Area Network, and is a means
899    to solve the scaling challenges of VLAN networks in a multi-tenant
900    environment. VXLAN is an overlay network which transports an L2 network
901    over an existing L3 network. For more information on VXLAN, please see
902    the IETF draft available here:
903
904    http://tools.ietf.org/html/draft-mahalingam-dutt-dcops-vxlan-03
905
906 Q: How much of the VXLAN protocol does Open vSwitch currently support?
907
908 A: Open vSwitch currently supports the framing format for packets on the
909    wire. There is currently no support for the multicast aspects of VXLAN.
910    To get around the lack of multicast support, it is possible to
911    pre-provision MAC to IP address mappings either manually or from a
912    controller.
913
914 Q: What destination UDP port does the VXLAN implementation in Open vSwitch
915    use?
916
917 A: By default, Open vSwitch will use the assigned IANA port for VXLAN, which
918    is 4789. However, it is possible to configure the destination UDP port
919    manually on a per-VXLAN tunnel basis. An example of this configuration is
920    provided below.
921
922    ovs-vsctl add-br br0
923    ovs-vsctl add-port br0 vxlan1 -- set interface vxlan1
924        type=vxlan options:remote_ip=192.168.1.2 options:key=flow
925        options:dst_port=8472
926
927
928 Using OpenFlow (Manually or Via Controller)
929 -------------------------------------------
930
931 Q: What versions of OpenFlow does Open vSwitch support?
932
933 A: Open vSwitch 1.9 and earlier support only OpenFlow 1.0 (plus
934    extensions that bring in many of the features from later versions
935    of OpenFlow).
936
937    Open vSwitch versions 1.10 and later will have experimental support
938    for OpenFlow 1.2 and 1.3.  On these versions of Open vSwitch, the
939    following command enables OpenFlow 1.0, 1.2, and 1.3 on bridge br0:
940
941        ovs-vsctl set bridge br0 protocols=OpenFlow10,OpenFlow12,OpenFlow13
942
943    Support for OpenFlow 1.1 is incomplete enough that it cannot yet be
944    enabled, even experimentally.
945
946    Support for OpenFlow 1.2 and 1.3 is still incomplete.  Work to be
947    done is tracked in OPENFLOW-1.1+ in the Open vSwitch source tree
948    (also via http://openvswitch.org/development/openflow-1-x-plan/).
949    When support for a given OpenFlow version is solidly implemented,
950    Open vSwitch will enable that version by default.
951
952 Q: I'm getting "error type 45250 code 0".  What's that?
953
954 A: This is a Open vSwitch extension to OpenFlow error codes.  Open
955    vSwitch uses this extension when it must report an error to an
956    OpenFlow controller but no standard OpenFlow error code is
957    suitable.
958
959    Open vSwitch logs the errors that it sends to controllers, so the
960    easiest thing to do is probably to look at the ovs-vswitchd log to
961    find out what the error was.
962
963    If you want to dissect the extended error message yourself, the
964    format is documented in include/openflow/nicira-ext.h in the Open
965    vSwitch source distribution.  The extended error codes are
966    documented in lib/ofp-errors.h.
967
968 Q1: Some of the traffic that I'd expect my OpenFlow controller to see
969     doesn't actually appear through the OpenFlow connection, even
970     though I know that it's going through.
971 Q2: Some of the OpenFlow flows that my controller sets up don't seem
972     to apply to certain traffic, especially traffic between OVS and
973     the controller itself.
974
975 A: By default, Open vSwitch assumes that OpenFlow controllers are
976    connected "in-band", that is, that the controllers are actually
977    part of the network that is being controlled.  In in-band mode,
978    Open vSwitch sets up special "hidden" flows to make sure that
979    traffic can make it back and forth between OVS and the controllers.
980    These hidden flows are higher priority than any flows that can be
981    set up through OpenFlow, and they are not visible through normal
982    OpenFlow flow table dumps.
983
984    Usually, the hidden flows are desirable and helpful, but
985    occasionally they can cause unexpected behavior.  You can view the
986    full OpenFlow flow table, including hidden flows, on bridge br0
987    with the command:
988
989        ovs-appctl bridge/dump-flows br0
990
991    to help you debug.  The hidden flows are those with priorities
992    greater than 65535 (the maximum priority that can be set with
993    OpenFlow).
994
995    The DESIGN file at the top level of the Open vSwitch source
996    distribution describes the in-band model in detail.
997
998    If your controllers are not actually in-band (e.g. they are on
999    localhost via 127.0.0.1, or on a separate network), then you should
1000    configure your controllers in "out-of-band" mode.  If you have one
1001    controller on bridge br0, then you can configure out-of-band mode
1002    on it with:
1003
1004        ovs-vsctl set controller br0 connection-mode=out-of-band
1005
1006 Q: I configured all my controllers for out-of-band control mode but
1007    "ovs-appctl bridge/dump-flows" still shows some hidden flows.
1008
1009 A: You probably have a remote manager configured (e.g. with "ovs-vsctl
1010    set-manager").  By default, Open vSwitch assumes that managers need
1011    in-band rules set up on every bridge.  You can disable these rules
1012    on bridge br0 with:
1013
1014        ovs-vsctl set bridge br0 other-config:disable-in-band=true
1015
1016    This actually disables in-band control entirely for the bridge, as
1017    if all the bridge's controllers were configured for out-of-band
1018    control.
1019
1020 Q: My OpenFlow controller doesn't see the VLANs that I expect.
1021
1022 A: See answer under "VLANs", above.
1023
1024 Q: I ran "ovs-ofctl add-flow br0 nw_dst=192.168.0.1,actions=drop"
1025    but I got a funny message like this:
1026
1027        ofp_util|INFO|normalization changed ofp_match, details:
1028        ofp_util|INFO| pre: nw_dst=192.168.0.1
1029        ofp_util|INFO|post:
1030
1031    and when I ran "ovs-ofctl dump-flows br0" I saw that my nw_dst
1032    match had disappeared, so that the flow ends up matching every
1033    packet.
1034
1035 A: The term "normalization" in the log message means that a flow
1036    cannot match on an L3 field without saying what L3 protocol is in
1037    use.  The "ovs-ofctl" command above didn't specify an L3 protocol,
1038    so the L3 field match was dropped.
1039
1040    In this case, the L3 protocol could be IP or ARP.  A correct
1041    command for each possibility is, respectively:
1042
1043        ovs-ofctl add-flow br0 ip,nw_dst=192.168.0.1,actions=drop
1044
1045    and 
1046
1047        ovs-ofctl add-flow br0 arp,nw_dst=192.168.0.1,actions=drop
1048
1049    Similarly, a flow cannot match on an L4 field without saying what
1050    L4 protocol is in use.  For example, the flow match "tp_src=1234"
1051    is, by itself, meaningless and will be ignored.  Instead, to match
1052    TCP source port 1234, write "tcp,tp_src=1234", or to match UDP
1053    source port 1234, write "udp,tp_src=1234".
1054
1055 Q: How can I figure out the OpenFlow port number for a given port?
1056
1057 A: The OFPT_FEATURES_REQUEST message requests an OpenFlow switch to
1058    respond with an OFPT_FEATURES_REPLY that, among other information,
1059    includes a mapping between OpenFlow port names and numbers.  From a
1060    command prompt, "ovs-ofctl show br0" makes such a request and
1061    prints the response for switch br0.
1062
1063    The Interface table in the Open vSwitch database also maps OpenFlow
1064    port names to numbers.  To print the OpenFlow port number
1065    associated with interface eth0, run:
1066
1067        ovs-vsctl get Interface eth0 ofport
1068
1069    You can print the entire mapping with:
1070
1071        ovs-vsctl -- --columns=name,ofport list Interface
1072
1073    but the output mixes together interfaces from all bridges in the
1074    database, so it may be confusing if more than one bridge exists.
1075
1076    In the Open vSwitch database, ofport value -1 means that the
1077    interface could not be created due to an error.  (The Open vSwitch
1078    log should indicate the reason.)  ofport value [] (the empty set)
1079    means that the interface hasn't been created yet.  The latter is
1080    normally an intermittent condition (unless ovs-vswitchd is not
1081    running).
1082
1083 Q: I added some flows with my controller or with ovs-ofctl, but when I
1084    run "ovs-dpctl dump-flows" I don't see them.
1085
1086 A: ovs-dpctl queries a kernel datapath, not an OpenFlow switch.  It
1087    won't display the information that you want.  You want to use
1088    "ovs-ofctl dump-flows" instead.
1089
1090 Q: It looks like each of the interfaces in my bonded port shows up
1091    as an individual OpenFlow port.  Is that right?
1092
1093 A: Yes, Open vSwitch makes individual bond interfaces visible as
1094    OpenFlow ports, rather than the bond as a whole.  The interfaces
1095    are treated together as a bond for only a few purposes:
1096
1097        - Sending a packet to the OFPP_NORMAL port.  (When an OpenFlow
1098          controller is not configured, this happens implicitly to
1099          every packet.)
1100
1101        - Mirrors configured for output to a bonded port.
1102
1103    It would make a lot of sense for Open vSwitch to present a bond as
1104    a single OpenFlow port.  If you want to contribute an
1105    implementation of such a feature, please bring it up on the Open
1106    vSwitch development mailing list at dev@openvswitch.org.
1107
1108 Q: I have a sophisticated network setup involving Open vSwitch, VMs or
1109    multiple hosts, and other components.  The behavior isn't what I
1110    expect.  Help!
1111
1112 A: To debug network behavior problems, trace the path of a packet,
1113    hop-by-hop, from its origin in one host to a remote host.  If
1114    that's correct, then trace the path of the response packet back to
1115    the origin.
1116
1117    Usually a simple ICMP echo request and reply ("ping") packet is
1118    good enough.  Start by initiating an ongoing "ping" from the origin
1119    host to a remote host.  If you are tracking down a connectivity
1120    problem, the "ping" will not display any successful output, but
1121    packets are still being sent.  (In this case the packets being sent
1122    are likely ARP rather than ICMP.)
1123
1124    Tools available for tracing include the following:
1125
1126        - "tcpdump" and "wireshark" for observing hops across network
1127          devices, such as Open vSwitch internal devices and physical
1128          wires.
1129
1130        - "ovs-appctl dpif/dump-flows <br>" in Open vSwitch 1.10 and
1131          later or "ovs-dpctl dump-flows <br>" in earlier versions.
1132          These tools allow one to observe the actions being taken on
1133          packets in ongoing flows.
1134
1135          See ovs-vswitchd(8) for "ovs-appctl dpif/dump-flows"
1136          documentation, ovs-dpctl(8) for "ovs-dpctl dump-flows"
1137          documentation, and "Why are there so many different ways to
1138          dump flows?" above for some background.
1139
1140        - "ovs-appctl ofproto/trace" to observe the logic behind how
1141          ovs-vswitchd treats packets.  See ovs-vswitchd(8) for
1142          documentation.  You can out more details about a given flow
1143          that "ovs-dpctl dump-flows" displays, by cutting and pasting
1144          a flow from the output into an "ovs-appctl ofproto/trace"
1145          command.
1146
1147        - SPAN, RSPAN, and ERSPAN features of physical switches, to
1148          observe what goes on at these physical hops.
1149
1150    Starting at the origin of a given packet, observe the packet at
1151    each hop in turn.  For example, in one plausible scenario, you
1152    might:
1153
1154        1. "tcpdump" the "eth" interface through which an ARP egresses
1155           a VM, from inside the VM.
1156
1157        2. "tcpdump" the "vif" or "tap" interface through which the ARP
1158           ingresses the host machine.
1159
1160        3. Use "ovs-dpctl dump-flows" to spot the ARP flow and observe
1161           the host interface through which the ARP egresses the
1162           physical machine.  You may need to use "ovs-dpctl show" to
1163           interpret the port numbers.  If the output seems surprising,
1164           you can use "ovs-appctl ofproto/trace" to observe details of
1165           how ovs-vswitchd determined the actions in the "ovs-dpctl
1166           dump-flows" output.
1167
1168        4. "tcpdump" the "eth" interface through which the ARP egresses
1169           the physical machine.
1170
1171        5. "tcpdump" the "eth" interface through which the ARP
1172           ingresses the physical machine, at the remote host that
1173           receives the ARP.
1174
1175        6. Use "ovs-dpctl dump-flows" to spot the ARP flow on the
1176           remote host that receives the ARP and observe the VM "vif"
1177           or "tap" interface to which the flow is directed.  Again,
1178           "ovs-dpctl show" and "ovs-appctl ofproto/trace" might help.
1179
1180        7. "tcpdump" the "vif" or "tap" interface to which the ARP is
1181           directed.
1182
1183        8. "tcpdump" the "eth" interface through which the ARP
1184           ingresses a VM, from inside the VM.
1185
1186    It is likely that during one of these steps you will figure out the
1187    problem.  If not, then follow the ARP reply back to the origin, in
1188    reverse.
1189
1190 Q: How do I make a flow drop packets?
1191
1192 A: An empty set of actions causes a packet to be dropped.  You can
1193    specify an empty set of actions with "actions=" on the ovs-ofctl
1194    command line.  For example:
1195
1196        ovs-ofctl add-flow br0 priority=65535,actions=
1197
1198    would cause every packet entering switch br0 to be dropped.
1199
1200    You can write "drop" explicitly if you like.  The effect is the
1201    same.  Thus, the following command also causes every packet
1202    entering switch br0 to be dropped:
1203
1204        ovs-ofctl add-flow br0 priority=65535,actions=drop
1205
1206
1207 Contact 
1208 -------
1209
1210 bugs@openvswitch.org
1211 http://openvswitch.org/