Factor vconn and SSL documentation into manpage include files.
[sliver-openvswitch.git] / utilities / ovs-openflowd.8.in
1 .TH ovs\-openflowd 8 "March 2009" "Open vSwitch" "Open vSwitch Manual"
2 .ds PN ovs\-openflowd
3
4 .SH NAME
5 ovs\-openflowd \- OpenFlow switch implementation
6
7 .SH SYNOPSIS
8 .B ovs\-openflowd
9 [\fIoptions\fR] \fIdatapath\fR [\fIcontroller\fR]
10
11 .SH DESCRIPTION
12 The \fBovs\-openflowd\fR program implements an OpenFlow switch using a
13 flow-based datapath.  \fBovs\-openflowd\fR connects to an OpenFlow controller
14 over TCP or SSL.
15
16 The mandatory \fIdatapath\fR argument argument specifies the local datapath
17 to relay.  It takes one of the following forms:
18
19 .so lib/dpif.man
20
21 .PP
22 The optional \fIcontroller\fR argument specifies how to connect to
23 the OpenFlow controller.  It takes one of the following forms:
24 .
25 .so lib/vconn-active.man
26 .
27 .PP
28 If \fIcontroller\fR is omitted, \fBovs\-openflowd\fR attempts to discover the
29 location of the controller automatically (see below).
30
31 .SS "Contacting the Controller"
32 The OpenFlow switch must be able to contact the OpenFlow controller
33 over the network.  It can do so in one of two ways:
34
35 .IP out-of-band
36 In this configuration, OpenFlow traffic uses a network separate from
37 the data traffic that it controls, that is, the switch does not use
38 any of the network devices added to the datapath with \fBovs\-dpctl
39 add\-if\fR in its communication with the controller.
40
41 To use \fBovs\-openflowd\fR in a network with out-of-band control, specify
42 \fB--out-of-band\fR on the \fBovs\-openflowd\fR command line.  The control
43 network must be configured separately, before or after \fBovs\-openflowd\fR
44 is started.
45
46 .IP in-band
47 In this configuration, a single network is used for OpenFlow traffic
48 and other data traffic, that is, the switch contacts the controller
49 over one of the network devices added to the datapath with \fBovs\-dpctl
50 add\-if\fR.  This configuration is often more convenient than
51 out-of-band control, because it is not necessary to maintain two
52 independent networks.
53
54 In-band control is the default for \fBovs\-openflowd\fR, so no special
55 command-line option is required.
56
57 With in-band control, the location of the controller can be configured
58 manually or discovered automatically:
59
60 .RS
61 .IP "controller discovery"
62 To make \fBovs\-openflowd\fR discover the location of the controller
63 automatically, do not specify the location of the controller on the
64 \fBovs\-openflowd\fR command line.
65
66 In this mode, \fBovs\-openflowd\fR will broadcast a DHCP request with vendor
67 class identifier \fBOpenFlow\fR across the network devices added to
68 the datapath with \fBovs\-dpctl add\-if\fR.  It will accept any valid DHCP
69 reply that has the same vendor class identifier and includes a
70 vendor-specific option with code 1 whose contents are a string
71 specifying the location of the controller in the same format used on
72 the \fBovs\-openflowd\fR command line (e.g. \fBssl:192.168.0.1\fR).
73
74 The DHCP reply may also, optionally, include a vendor-specific option
75 with code 2 whose contents are a string specifying the URI to the base
76 of the OpenFlow PKI (e.g. \fBhttp://192.168.0.1/openflow/pki\fR).
77 This URI is used only for bootstrapping the OpenFlow PKI at initial
78 switch setup; \fBovs\-openflowd\fR does not use it at all.
79
80 The following ISC DHCP server configuration file assigns the IP
81 address range 192.168.0.20 through 192.168.0.30 to OpenFlow switches
82 that follow the switch protocol and addresses 192.168.0.1 through
83 192.168.0.10 to all other DHCP clients:
84
85 default-lease-time 600;
86 .br
87 max-lease-time 7200;
88 .br
89 option space openflow;
90 .br
91 option openflow.controller-vconn code 1 = text;
92 .br
93 option openflow.pki-uri code 2 = text;
94 .br
95 class "OpenFlow" {
96 .br
97   match if option vendor-class-identifier = "OpenFlow";
98 .br
99   vendor-option-space openflow;
100 .br
101   option openflow.controller-vconn "tcp:192.168.0.10";
102 .br
103   option openflow.pki-uri "http://192.168.0.10/openflow/pki";
104 .br
105   option vendor-class-identifier "OpenFlow";
106 .br
107 }
108 .br
109 subnet 192.168.0.0 netmask 255.255.255.0 {
110 .br
111     pool {
112 .br
113         allow members of "OpenFlow";
114 .br
115         range 192.168.0.20 192.168.0.30;
116 .br
117     }
118 .br
119     pool {
120 .br
121         deny members of "OpenFlow";
122 .br
123         range 192.168.0.1 192.168.0.10;
124 .br
125     }
126 .br
127 }
128 .br
129
130 .IP "manual configuration"
131 To configure in-band control manually, specify the location of the
132 controller on the \fBovs\-openflowd\fR command line as the \fIcontroller\fR
133 argument.  You must also configure the network device for the OpenFlow
134 ``local port'' to allow \fBovs\-openflowd\fR to connect to that controller.
135 The OpenFlow local port is a virtual network port that \fBovs\-openflowd\fR
136 bridges to the physical switch ports.  The name of the local port for
137 a given \fIdatapath\fR may be seen by running \fBovs\-dpctl show
138 \fIdatapath\fR; the local port is listed as port 0 in \fBshow\fR's
139 output.
140
141 .IP
142 Before \fBovs\-openflowd\fR starts, the local port network device is not
143 bridged to any physical network, so the next step depends on whether
144 connectivity is required to configure the device's IP address.  If the
145 switch has a static IP address, you may configure its IP address now
146 with a command such as 
147 .B ifconfig of0 192.168.1.1
148 and then invoke \fBovs\-openflowd\fR.
149
150 On the other hand, if the switch does not have a static IP address,
151 e.g. it obtains its IP address dynamically via DHCP, the DHCP client
152 will not be able to contact the DHCP server until the OpenFlow switch
153 has started up.  Thus, start \fBovs\-openflowd\fR without configuring
154 the local port network device, and start the DHCP client afterward.
155 .RE
156
157 .SH OPTIONS
158 .SS "Controller Discovery Options"
159 .TP
160 \fB--accept-vconn=\fIregex\fR
161 When \fBovs\-openflowd\fR performs controller discovery (see \fBContacting
162 the Controller\fR, above, for more information about controller
163 discovery), it validates the controller location obtained via DHCP
164 with a POSIX extended regular expression.  Only controllers whose
165 names match the regular expression will be accepted.
166
167 The default regular expression is \fBssl:.*\fR (meaning that only SSL
168 controller connections will be accepted) when any of the SSL
169 configuration options \fB--private-key\fR, \fB--certificate\fR, or
170 \fB--ca-cert\fR is specified.  The default is \fB^tcp:.*\fR otherwise
171 (meaning that only TCP controller connections will be accepted).
172
173 The \fIregex\fR is implicitly anchored at the beginning of the
174 controller location string, as if it begins with \fB^\fR.
175
176 When controller discovery is not performed, this option has no effect.
177
178 .TP
179 \fB--no-resolv-conf\fR
180 When \fBovs\-openflowd\fR performs controller discovery (see \fBContacting
181 the Controller\fR, above, for more information about controller
182 discovery), by default it overwrites the system's
183 \fB/etc/resolv.conf\fR with domain information and DNS servers
184 obtained via DHCP.  If the location of the controller is specified
185 using a hostname, rather than an IP address, and the network's DNS
186 servers ever change, this behavior is essential.  But because it also
187 interferes with any administrator or process that manages
188 \fB/etc/resolv.conf\fR, when this option is specified, \fBovs\-openflowd\fR
189 will not modify \fB/etc/resolv.conf\fR.
190
191 \fBovs\-openflowd\fR will only modify \fBresolv.conf\fR if the DHCP response
192 that it receives specifies one or more DNS servers.
193
194 When controller discovery is not performed, this option has no effect.
195
196 .SS "Networking Options"
197 .TP
198 \fB--datapath-id=\fIdpid\fR
199 Sets \fIdpid\fR, which must consist of exactly 12 hexadecimal digits,
200 as the datapath ID that the switch will use to identify itself to the
201 OpenFlow controller.
202
203 If this option is omitted, the default datapath ID is taken from the
204 Ethernet address of the datapath's local port (which is typically
205 randomly generated).
206
207 .TP
208 \fB--mgmt-id=\fImgmtid\fR
209 Sets \fImgmtid\fR, which must consist of exactly 12 hexadecimal
210 digits, as the switch's management ID.
211
212 If this option is omitted, the management ID defaults to 0, signaling
213 to the controller that management is supported but not configured.
214
215 .TP
216 \fB--fail=\fR[\fBopen\fR|\fBclosed\fR]
217 The controller is, ordinarily, responsible for setting up all flows on
218 the OpenFlow switch.  Thus, if the connection to the controller fails,
219 no new network connections can be set up.  If the connection to the
220 controller stays down long enough, no packets can pass through the
221 switch at all.
222
223 If this option is set to \fBopen\fR (the default), \fBovs\-openflowd\fR will
224 take over responsibility for setting up flows in the local datapath
225 when no message has been received from the controller for three times
226 the inactivity probe interval (see below), or 45 seconds by default.
227 In this ``fail open'' mode, \fBovs\-openflowd\fR causes the datapath to act
228 like an ordinary MAC-learning switch.  \fBovs\-openflowd\fR will continue to
229 retry connection to the controller in the background and, when the
230 connection succeeds, it discontinues its fail-open behavior.
231
232 If this option is set to \fBclosed\fR, then \fBovs\-openflowd\fR will not
233 set up flows on its own when the controller connection fails.
234
235 .TP
236 \fB--inactivity-probe=\fIsecs\fR
237 When the OpenFlow switch is connected to the controller, the
238 switch waits for a message to be received from the controller for
239 \fIsecs\fR seconds before it sends a inactivity probe to the
240 controller.  After sending the inactivity probe, if no response is
241 received for an additional \fIsecs\fR seconds, the switch
242 assumes that the connection has been broken and attempts to reconnect.
243 The default and the minimum value are both 5 seconds.
244
245 When fail-open mode is configured, changing the inactivity probe
246 interval also changes the interval before entering fail-open mode (see
247 above).
248
249 .TP
250 \fB--max-idle=\fIsecs\fR|\fBpermanent\fR
251 Sets \fIsecs\fR as the number of seconds that a flow set up by the
252 OpenFlow switch will remain in the switch's flow table without any
253 matching packets being seen.  If \fBpermanent\fR is specified, which
254 is not recommended, flows set up by the switch will never
255 expire.  The default is 15 seconds.
256
257 Most flows are set up by the OpenFlow controller, not by the
258 switch.  This option affects only the following flows, which the
259 OpenFlow switch sets up itself:
260
261 .RS
262 .IP \(bu
263 When \fB--fail=open\fR is specified, flows set up when the
264 switch has not been able to contact the controller for the configured
265 fail-open delay.
266
267 .IP \(bu
268 When in-band control is in use, flows set up to bootstrap contacting
269 the controller (see \fBContacting the Controller\fR, above, for
270 more information about in-band control).
271 .RE
272
273 .IP
274 As a result, when both \fB--fail=closed\fR and \fB--out-of-band\fR are
275 specified, this option has no effect.
276
277 .TP
278 \fB--max-backoff=\fIsecs\fR
279 Sets the maximum time between attempts to connect to the controller to
280 \fIsecs\fR, which must be at least 1.  The actual interval between
281 connection attempts starts at 1 second and doubles on each failing
282 attempt until it reaches the maximum.  The default maximum backoff
283 time is 8 seconds.
284
285 .TP
286 \fB-l\fR, \fB--listen=\fImethod\fR
287 By default, the switch listens for OpenFlow management connections on a
288 Unix domain socket named \fB@RUNDIR@/\fIdatapath\fB.mgmt\fR.  This socket 
289 can be used to perform local OpenFlow monitoring and administration with
290 tools such as \fBovs\-ofctl\fR.  
291
292 This option may be used to override the default listener.  The \fImethod\fR
293 must be given as one of the passive OpenFlow connection methods listed
294 below.  This option may be specified multiple times to listen to
295 multiple connection methods.  If a single \fImethod\fR of \fBnone\fR is
296 used, no listeners will be created.
297
298 .RS
299 .so lib/vconn-passive.man
300 .RE
301
302 .TP
303 \fB--snoop=\fImethod\fR
304 Configures the switch to additionally listen for incoming OpenFlow
305 connections for controller connection snooping.  The \fImethod\fR must
306 be given as one of the passive OpenFlow connection methods listed
307 under the \fB--listen\fR option above.  This option may be specified
308 multiple times to listen to multiple connection methods.
309
310 If \fBovs\-ofctl monitor\fR is used to connect to \fImethod\fR specified on
311 \fB--snoop\fR, it will display all the OpenFlow messages traveling
312 between the switch and its controller on the primary OpenFlow
313 connection.  This can be useful for debugging switch and controller
314 problems.
315
316 .TP
317 \fB--in-band\fR, \fB--out-of-band\fR
318 Configures \fBovs\-openflowd\fR to operate in in-band or out-of-band control
319 mode (see \fBContacting the Controller\fR above).  When neither option
320 is given, the default is in-band control.
321
322 .TP
323 \fB--netflow=\fIip\fB:\fIport\fR
324 Configures the given UDP \fIport\fR on the specified IP \fIip\fR as
325 a recipient of NetFlow messages for expired flows.  The \fIip\fR must
326 be specified numerically, not as a DNS name.
327
328 This option may be specified multiple times to configure additional
329 NetFlow collectors.
330
331 .SS "Rate-Limiting Options"
332
333 These options configure how the switch applies a ``token bucket'' to
334 limit the rate at which packets in unknown flows are forwarded to an
335 OpenFlow controller for flow-setup processing.  This feature prevents
336 a single OpenFlow switch from overwhelming a controller.
337
338 .TP
339 \fB--rate-limit\fR[\fB=\fIrate\fR]
340 .
341 Limits the maximum rate at which packets will be forwarded to the
342 OpenFlow controller to \fIrate\fR packets per second.  If \fIrate\fR
343 is not specified then the default of 1,000 packets per second is used.
344
345 If \fB--rate-limit\fR is not used, then the switch does not limit the
346 rate at which packets are forwarded to the controller.
347
348 .TP
349 \fB--burst-limit=\fIburst\fR
350 .
351 Sets the maximum number of unused packet credits that the switch will
352 allow to accumulate during time in which no packets are being
353 forwarded to the OpenFlow controller to \fIburst\fR (measured in
354 packets).  The default \fIburst\fR is one-quarter of the \fIrate\fR
355 specified on \fB--rate-limit\fR.
356
357 This option takes effect only when \fB--rate-limit\fR is also specified.
358
359 .SS "Datapath Options"
360 .
361 .IP "\fB\-\-ports=\fIport\fR[\fB,\fIport\fR...]"
362 Ordinarily, \fBovs\-openflowd\fR expects the administrator to create
363 the specified \fIdatapath\fR and add ports to it externally with a
364 utility such as \fBovs\-dpctl\fR.  However, the userspace switch
365 datapath is implemented inside \fBovs\-openflowd\fR itself and does
366 not (currently) have any external interface for \fBovs\-dpctl\fR to
367 access.  As a stopgap measure, this option specifies one or more ports
368 to add to the datapath at \fBovs\-openflowd\fR startup time.  Multiple
369 ports may be specified as a comma-separated list or by specifying
370 \fB\-\-ports\fR multiple times.
371 .IP
372 See \fBINSTALL.userspace\fR for more information about userspace
373 switching.
374
375 .SS "Daemon Options"
376 .so lib/daemon.man
377
378 .so lib/ssl.man
379 .so lib/ssl-bootstrap.man
380
381 .SS "Logging Options"
382 .so lib/vlog.man
383 .SS "Other Options"
384 .so lib/common.man
385 .so lib/leak-checker.man
386
387 .SH "SEE ALSO"
388
389 .BR ovs\-appctl (8),
390 .BR ovs\-controller (8),
391 .BR ovs\-discover (8),
392 .BR ovs\-dpctl (8),
393 .BR ovs\-ofctl (8),