docs: Move PKI section heading into individual manpages.
[sliver-openvswitch.git] / vswitchd / ovs-vswitchd.8.in
1 .\" -*- nroff -*-
2 .de IQ
3 .  br
4 .  ns
5 .  IP "\\$1"
6 ..
7 .TH ovs\-vswitchd 8 "June 2009" "Open vSwitch" "Open vSwitch Manual"
8 .ds PN ovs\-vswitchd
9 .
10 .SH NAME
11 ovs\-vswitchd \- Open vSwitch daemon
12 .
13 .SH SYNOPSIS
14 .B ovs\-vswitchd
15 \fIdatabase\fR
16 .
17 .SH DESCRIPTION
18 A daemon that manages and controls any number of Open vSwitch switches 
19 on the local machine.
20 .PP
21 The mandatory \fIdatabase\fR argument specifies the
22 \fBovsdb\-server\fR from which \fBovs\-vswitchd\fR's configuration
23 should be retrieved.  It takes one of the following forms:
24 .so ovsdb/remote-active.man
25 .PP
26 \fBovs\-vswitchd\fR retrieves its configuration from \fIdatabase\fR at
27 startup.  It sets up Open vSwitch datapaths and then operates
28 switching across each bridge described in its configuration files.  As
29 the database changes, \fBovs\-vswitchd\fR automatically updates its
30 configuration to match.
31 .PP
32 Upon receipt of a SIGHUP signal, \fBovs\-vswitchd\fR reopens its log
33 file, if one was specified on the command line.
34 .PP
35 \fBovs\-vswitchd\fR switches may be configured with any of the following 
36 features:
37 .
38 .IP \(bu
39 L2 switching with MAC learning.
40 .
41 .IP \(bu
42 NIC bonding with automatic fail-over and source MAC-based TX load
43 balancing ("SLB").
44 .
45 .IP \(bu
46 802.1Q VLAN support.
47 .
48 .IP \(bu
49 Port mirroring, with optional VLAN tagging.
50 .
51 .IP \(bu
52 NetFlow v5 flow logging.
53 .
54 .IP \(bu
55 sFlow(R) monitoring.
56 .
57 .IP \(bu
58 Connectivity to an external OpenFlow controller, such as NOX.
59 .
60 .PP
61 Only a single instance of \fBovs\-vswitchd\fR is intended to run at a time.
62 A single \fBovs\-vswitchd\fR can manage any number of switch instances, up
63 to the maximum number of supported Open vSwitch datapaths.
64 .PP
65 \fBovs\-vswitchd\fR does all the necessary management of Open vSwitch datapaths
66 itself.  Thus, external tools, such \fBovs\-dpctl\fR(8), are not needed for
67 managing datapaths in conjunction with \fBovs\-vswitchd\fR, and their use
68 to modify datapaths when \fBovs\-vswitchd\fR is running can interfere with
69 its operation.  (\fBovs\-dpctl\fR may still be useful for diagnostics.)
70 .PP
71 An Open vSwitch datapath kernel module must be loaded for \fBovs\-vswitchd\fR
72 to be useful.  Please refer to the \fBINSTALL.Linux\fR file included in the
73 Open vSwitch distribution for instructions on how to build and load
74 the Open vSwitch kernel module.
75 .PP
76 .SH OPTIONS
77 .IP "\fB--fake-proc-net\fR"
78 Causes \fBovs\-vswitchd\fR to simulate some files in \fB/proc/net/vlan\fR
79 and \fB/proc/net/bonding\fR that some legacy software expects to
80 exist.  This option should only be used if such legacy software is
81 actually in use.  It requires the \fBbrcompat_mod.ko\fR kernel module
82 to be loaded.
83 .
84 .so lib/daemon.man
85 .SS "Public Key Infrastructure Options"
86 .so lib/ssl.man
87 .so lib/ssl-bootstrap.man
88 .so lib/vlog.man
89 .so lib/common.man
90 .so lib/leak-checker.man
91 .
92 .SH "RUNTIME MANAGEMENT COMMANDS"
93 \fBovs\-appctl\fR(8) can send commands to a running
94 \fBovs\-vswitchd\fR process.  The currently supported commands are
95 described below.  The command descriptions assume an understanding of
96 how to configure Open vSwitch.
97 .SS "BRIDGE COMMANDS"
98 These commands manage bridges.
99 .IP "\fBfdb/show\fR \fIbridge\fR"
100 Lists each MAC address/VLAN pair learned by the specified \fIbridge\fR,
101 along with the port on which it was learned and the age of the entry,
102 in seconds.
103 .
104 .IP "\fBbridge/dump-flows\fR \fIbridge\fR"
105 Lists all flows in \fIbridge\fR, including those normally hidden to
106 commands such as \fBovs-ofctl dump-flows\fR.  Flows set up by mechanisms
107 such as in-band control and fail-open are hidden from the controller
108 since it is not allowed to modify or override them.
109 .SS "BOND COMMANDS"
110 These commands manage bonded ports on an Open vSwitch's bridges.  To
111 understand some of these commands, it is important to understand a
112 detail of the bonding implementation called ``MAC hashing.''  Instead
113 of directly assigning Ethernet source addresses to slaves, the bonding
114 implementation computes a function that maps an 48-bit Ethernet source
115 addresses into an 8-bit value (a ``MAC hash'' value).  All of the
116 Ethernet addresses that map to a single 8-bit value are then assigned
117 to a single slave.
118 .IP "\fBbond/list\fR"
119 Lists all of the bonds, and their slaves, on each bridge.
120 .
121 .IP "\fBbond/show\fR \fIport\fR"
122 Lists all of the bond-specific information about the given bonded
123 \fIport\fR: updelay, downdelay, time until the next rebalance.  Also
124 lists information about each slave: whether it is enabled or disabled,
125 the time to completion of an updelay or downdelay if one is in
126 progress, whether it is the active slave, the MAC hashes assigned to
127 the slave, and the MAC learning table entries that hash to each MAC.
128 .IP "\fBbond/migrate\fR \fIport\fR \fIhash\fR \fIslave\fR"
129 Assigns a given MAC hash to a new slave.  \fIport\fR specifies the
130 bond port, \fIhash\fR either the MAC hash to be migrated (as a decimal
131 number between 0 and 255) or an Ethernet address to be hashed, and
132 \fIslave\fR the new slave to be assigned.
133 .IP
134 The reassignment is not permanent: rebalancing or fail-over will
135 cause the MAC hash to be shifted to a new slave in the usual
136 manner.
137 .IP
138 A MAC hash cannot be migrated to a disabled slave.
139 .IP "\fBbond/set-active-slave\fR \fIport\fR \fIslave\fR"
140 Sets \fIslave\fR as the active slave on \fIport\fR.  \fIslave\fR must
141 currently be enabled.
142 .IP
143 The setting is not permanent: a new active slave will be selected
144 if \fIslave\fR becomes disabled.
145 .IP "\fBbond/enable-slave\fR \fIport\fR \fIslave\fR"
146 .IQ "\fBbond/disable-slave\fR \fIport\fR \fIslave\fR"
147 Enables (or disables) \fIslave\fR on the given bond \fIport\fR, skipping any
148 updelay (or downdelay).
149 .IP
150 This setting is not permanent: it persists only until the carrier
151 status of \fIslave\fR changes.
152 .IP "\fBbond/hash\fR \fImac\fR"
153 Returns the hash value which would be used for \fImac\fR.
154 .
155 .so lib/vlog-unixctl.man
156 .SH "SEE ALSO"
157 .BR ovs\-appctl (8),
158 .BR ovs\-brcompatd (8),