daemon: Remove short options from daemon library
[sliver-openvswitch.git] / xenserver / etc_init.d_vswitch
1 #!/bin/bash
2 #
3 # vswitch
4 #
5 # chkconfig: 2345 09 91
6 # description: Manage vswitch kernel modules and user-space daemon
7
8 # Copyright (C) 2009 Nicira Networks, Inc.
9 #
10 # Licensed under the Apache License, Version 2.0 (the "License");
11 # you may not use this file except in compliance with the License.
12 # You may obtain a copy of the License at:
13 #
14 #     http://www.apache.org/licenses/LICENSE-2.0
15 #
16 # Unless required by applicable law or agreed to in writing, software
17 # distributed under the License is distributed on an "AS IS" BASIS,
18 # WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
19 # See the License for the specific language governing permissions and
20 # limitations under the License.
21
22 . /etc/init.d/functions
23
24 test -e /etc/sysconfig/vswitch && . /etc/sysconfig/vswitch
25
26 # General config variables in /etc/sysconfig/vswitch
27 VSWITCH_BASE="${VSWITCH_BASE:-/root/vswitch}"
28 ENABLE_BRCOMPAT="${ENABLE_BRCOMPAT:-y}"
29 ENABLE_FAKE_PROC_NET="${ENABLE_FAKE_PROC_NET:-y}"
30 FORCE_COREFILES="${FORCE_COREFILES:-n}"
31 COREFILE_PATTERN="${COREFILE_PATTERN:-/var/log/%e-%t}"
32
33 # Config variables specific to ovs-vswitchd
34 VSWITCHD_CONF="${VSWITCHD_CONF:-/etc/ovs-vswitchd.conf}"
35 VSWITCHD_PIDFILE="${VSWITCHD_PIDFILE:-/var/run/ovs-vswitchd.pid}"
36 VSWITCHD_PRIORITY="${VSWITCHD_PRIORITY:--5}"
37 VSWITCHD_LOGFILE="${VSWITCHD_LOGFILE:-/var/log/ovs-vswitchd.log}"
38 VSWITCHD_FILE_LOGLEVEL="${VSWITCHD_FILE_LOGLEVEL:-}"
39 VSWITCHD_SYSLOG_LOGLEVEL="${VSWITCHD_SYSLOG_LOGLEVEL:-WARN}"
40 VSWITCHD_MEMLEAK_LOGFILE="${VSWITCHD_MEMLEAK_LOGFILE:-}"
41 VSWITCHD_STRACE_LOG="${VSWITCHD_STRACE_LOG:-}"
42 VSWITCHD_STRACE_OPT="${VSWITCHD_STRACE_OPT:-}"
43 VSWITCHD_VALGRIND_LOG="${VSWITCHD_VALGRIND_LOG:-}"
44 VSWITCHD_VALGRIND_OPT="${VSWITCHD_VALGRIND_OPT:-}"
45
46 # Config variables specific to ovs-brcompatd
47 BRCOMPATD_PIDFILE="${BRCOMPATD_PIDFILE:-/var/run/ovs-brcompatd.pid}"
48 BRCOMPATD_PRIORITY="${BRCOMPATD_PRIORITY:--5}"
49 BRCOMPATD_LOGFILE="${BRCOMPATD_LOGFILE:-/var/log/ovs-brcompatd.log}"
50 BRCOMPATD_FILE_LOGLEVEL="${BRCOMPATD_FILE_LOGLEVEL:-}"
51 BRCOMPATD_SYSLOG_LOGLEVEL="${BRCOMPATD_SYSLOG_LOGLEVEL:-INFO}"
52 BRCOMPATD_MEMLEAK_LOGFILE="${BRCOMPATD_MEMLEAK_LOGFILE:-}"
53 BRCOMPATD_STRACE_LOG="${BRCOMPATD_STRACE_LOG:-}"
54 BRCOMPATD_STRACE_OPT="${BRCOMPATD_STRACE_OPT:-}"
55 BRCOMPATD_VALGRIND_LOG="${BRCOMPATD_VALGRIND_LOG:-}"
56 BRCOMPATD_VALGRIND_OPT="${BRCOMPATD_VALGRIND_OPT:-}"
57
58
59
60
61 # Full paths to executables & modules
62 vswitchd="$VSWITCH_BASE/sbin/ovs-vswitchd"
63 brcompatd="$VSWITCH_BASE/sbin/ovs-brcompatd"
64 dpctl="$VSWITCH_BASE/bin/ovs-dpctl"
65 appctl="$VSWITCH_BASE/bin/ovs-appctl"
66 ofctl="$VSWITCH_BASE/bin/ovs-ofctl"
67
68
69 if [ "$ENABLE_FAKE_PROC_NET" == "y" ]; then
70     if [ "$ENABLE_BRCOMPAT" != "y" ]; then
71         warning "FAKE_PROC_NET required BRCOMPAT which was disabled.  Force enabling."
72         ENABLE_BRCOMPAT="y"
73     fi
74 fi
75
76 function dp_list {
77     "$dpctl" show | grep '^dp[0-9]\+:' | cut -d':' -f 1
78 }
79
80 function turn_on_corefiles {
81     # This has global effect so should not normally be used...
82     ulimit -c unlimited
83     echo "$COREFILE_PATTERN" > /proc/sys/kernel/core_pattern
84 }
85
86 function remove_all_dp {
87     for dp in $(dp_list); do
88         action "Removing datapath: $dp" "$dpctl" del-dp "$dp"
89     done
90 }
91
92 function insert_modules_if_required {
93     if ! lsmod | grep -q "openvswitch_mod"; then
94         action "Inserting llc module" modprobe llc
95         action "Inserting openvswitch module" insmod $VSWITCH_BASE/kernel_modules/openvswitch_mod.ko
96     fi
97     if [ -n "$BRCOMPATD_PIDFILE" ] && ! lsmod | grep -q "brcompat_mod"; then
98         action "Inserting brcompat module" insmod $VSWITCH_BASE/kernel_modules/brcompat_mod.ko
99     fi
100 }
101
102 function remove_modules {
103     if lsmod | grep -q "brcompat_mod"; then
104         action "Removing brcompat module" rmmod brcompat_mod.ko
105     fi
106     if lsmod | grep -q "openvswitch_mod"; then
107         action "Removing openvswitch module" rmmod openvswitch_mod.ko
108     fi
109 }
110
111 function reload_vswitchd {
112     if [ -f "$VSWITCHD_PIDFILE" ]; then
113         "$appctl" \
114             --target=ovs-vswitchd.$(cat "$VSWITCHD_PIDFILE").ctl \
115             --execute=vswitchd/reload
116     fi
117 }
118
119 function start_vswitchd {
120     local syslog_opt="-vANY:SYSLOG:${VSWITCHD_SYSLOG_LOGLEVEL}"
121     local logfile_file_opt=""
122     local logfile_level_opt=""
123     if [ -n "$VSWITCHD_FILE_LOGLEVEL" ]; then
124         logfile_level_opt="-vANY:FILE:${VSWITCHD_FILE_LOGLEVEL}"
125         logfile_file_opt="--log-file=$VSWITCHD_LOGFILE"
126     fi
127     local leak_opt=""
128     if [ -n "$VSWITCHD_MEMLEAK_LOGFILE" ]; then
129         leak_opt="--check-leaks=$VSWITCHD_MEMLEAK_LOGFILE"
130         if [ -e "$VSWITCHD_MEMLEAK_LOGFILE" ]; then
131             mv "$VSWITCHD_MEMLEAK_LOGFILE" "$VSWITCHD_MEMLEAK_LOGFILE.prev"
132         fi
133     fi
134     local strace_opt=""
135     local daemonize="y"
136     if [ -n "$VSWITCHD_STRACE_LOG" ] && [ -n "$VSWITCHD_VALGRIND_LOG" ]; then
137         printf "Can not start with both VALGRIND and STRACE\n"
138         exit 1
139     fi
140     if [ -n "$VSWITCHD_STRACE_LOG" ]; then
141         strace_opt="strace -o $VSWITCHD_STRACE_LOG $VSWITCHD_STRACE_OPT"
142         daemonize="n"
143     fi
144     if [ -n "$VSWITCHD_VALGRIND_LOG" ]; then
145         valgrind_opt="valgrind --log-file=$VSWITCHD_VALGRIND_LOG $VSWITCHD_VALGRIND_OPT"
146         daemonize="n"
147     fi
148     local fake_proc_net_opt=""
149     if [ "$ENABLE_FAKE_PROC_NET" == "y" ]; then
150         fake_proc_net_opt="--fake-proc-net"
151     fi
152     if [ "$daemonize" != "y" ]; then
153         # Start in background and force a "success" message
154         action "Starting ovs-vswitchd ($strace_opt$valgrind_opt)" true
155         (nice -n "$VSWITCHD_PRIORITY" $strace_opt $valgrind_opt "$vswitchd" --pidfile="$VSWITCHD_PIDFILE" --detach $fake_proc_net_opt -vANY:CONSOLE:EMER $syslog_opt $logfile_level_opt $logfile_file_opt $leak_opt "$VSWITCHD_CONF") &
156     else
157         action "Starting ovs-vswitchd" nice -n "$VSWITCHD_PRIORITY" "$vswitchd" --pidfile="$VSWITCHD_PIDFILE" --detach $fake_proc_net_opt -vANY:CONSOLE:EMER $syslog_opt $logfile_level_opt $logfile_file_opt $leak_opt "$VSWITCHD_CONF"
158     fi
159 }
160
161 function start_brcompatd {
162     local syslog_opt="-vANY:SYSLOG:${BRCOMPATD_SYSLOG_LOGLEVEL}"
163     local logfile_file_opt=""
164     local logfile_level_opt=""
165     if [ -n "$BRCOMPATD_FILE_LOGLEVEL" ]; then
166         logfile_level_opt="-vANY:FILE:${BRCOMPATD_FILE_LOGLEVEL}"
167         logfile_file_opt="--log-file=$BRCOMPATD_LOGFILE"
168     fi
169     local leak_opt=""
170     if [ -n "$BRCOMPATD_MEMLEAK_LOG" ]; then
171         leak_opt="--check-leaks=$BRCOMPATD_MEMLEAK_LOGFILE"
172         if [ -e "$BRCOMPATD_MEMLEAK_LOGFILE" ]; then
173             mv "$BRCOMPATD_MEMLEAK_LOGFILE" "$BRCOMPATD_MEMLEAK_LOGFILE.prev"
174         fi
175     fi
176     local strace_opt=""
177     local daemonize="y"
178     if [ -n "$BRCOMPATD_STRACE_LOG" ] && [ -n "$BRCOMPATD_VALGRIND_LOG" ]; then
179         printf "Can not start with both VALGRIND and STRACE\n"
180         exit 1
181     fi
182     if [ -n "$BRCOMPATD_STRACE_LOG" ]; then
183         strace_opt="strace -o $BRCOMPATD_STRACE_LOG $BRCOMPATD_STRACE_OPT"
184         daemonize="n"
185     fi
186     if [ -n "$VALGRIND_LOG" ]; then
187         valgrind_opt="valgrind --log-file=$BRCOMPATD_VALGRIND_LOG $BRCOMPATD_VALGRIND_OPT"
188         daemonize="n"
189     fi
190     appctl_cmd="$appctl -t /var/run/ovs-vswitchd.\`cat $VSWITCHD_PIDFILE\`.ctl -e '%s'"
191     if [ "$daemonize" != "y" ]; then
192         # Start in background and force a "success" message
193         action "Starting ovs-brcompatd ($strace_opt$valgrind_opt)" true
194         (nice -n "$VSWITCHD_PRIORITY" $strace_opt $valgrind_opt "$brcompatd" --appctl-command="$appctl_cmd" --pidfile=$BRCOMPATD_PIDFILE -vANY:CONSOLE:EMER $syslog_opt $logfile_level_opt $logfile_file_opt $leak_opt "$VSWITCHD_CONF") &
195     else
196         action "Starting ovs-brcompatd" nice -n "$BRCOMPATD_PRIORITY" $strace_opt $valgrind_opt "$brcompatd" --appctl-command="$appctl_cmd" --pidfile=$BRCOMPATD_PIDFILE --detach -vANY:CONSOLE:EMER $syslog_opt $logfile_level_opt $logfile_file_opt $leak_opt "$VSWITCHD_CONF"
197     fi
198 }
199
200 function stop_vswitchd {
201     if [ -f "$VSWITCHD_PIDFILE" ]; then
202         local pid=$(cat "$VSWITCHD_PIDFILE")
203         action "Killing ovs-vswitchd ($pid)" kill -TERM $pid
204         rm -f "$VSWITCHD_PIDFILE"
205     fi
206 }
207
208 function stop_brcompatd {
209     if [ -f "$BRCOMPATD_PIDFILE" ]; then
210         local pid=$(cat "$BRCOMPATD_PIDFILE")
211         action "Killing ovs-brcompatd ($pid)" kill -TERM $pid
212         rm -f "$BRCOMPATD_PIDFILE"
213     fi
214 }
215
216 function restart_approval {
217     if test ! -t 0; then
218         # Don't prompt if invoked non-interactively.
219         return 0
220     fi
221     cat <<EOF
222
223 WARNING!!!
224
225 Restarting vswitch on a live server is not guaranteed to work.  It is
226 provided as a convenience for those situations in which it does work.
227 If you just want to reload the configuration file, use "reload"
228 instead of restart.
229
230 EOF
231     read -s -r -n 1 -p "Countinue with restart (y/N): " response
232     printf "\n"
233     case "$response" in
234         y|Y)
235             return 0
236             ;;
237         *)
238             return 1
239             ;;
240     esac
241 }
242
243 function start {
244     if [ "$FORCE_COREFILES" = "y" ]; then
245         turn_on_corefiles
246     fi
247
248     insert_modules_if_required
249     start_vswitchd
250     start_brcompatd
251     reload_vswitchd  # ensures ovs-vswitchd has fully read config file.
252 }
253
254 function stop {
255     stop_brcompatd
256     stop_vswitchd
257 }
258
259 function restart {
260     if restart_approval; then
261         stop
262         start
263     fi
264 }
265
266 case "$1" in
267     start)
268         start
269         ;;
270     stop)
271         stop
272         ;;
273     restart)
274         restart
275         ;;
276     reload)
277         reload_vswitchd
278         ;;
279     strace-vswitchd)
280         shift
281         strace -p $(cat "$VSWITCHD_PIDFILE") "$@"
282         ;;
283     strace-brcompatd)
284         shift
285         strace -p $(cat "$BRCOMPATD_PIDFILE") "$@"
286         ;;
287     status)
288         status -p ovs-vswitchd.pid ovs-vswitchd
289         status -p ovs-brcompatd.pid ovs-brcompatd
290         ;;
291     version)
292         "$VSWITCH_BASE"/sbin/ovs-vswitchd -V
293         "$VSWITCH_BASE"/sbin/ovs-brcompatd -V
294         ;;
295     help)
296         printf "vswitch [start|stop|restart|reload|unload|status|version]\n"
297         ;;
298     *)
299         printf "Unknown command: $1\n"
300         exit 1
301         ;;
302 esac