1 #!/bin/bash
2 #
3 # vswitch
4 #
5 # chkconfig: 2345 09 91
6 # description: Manage vswitch kernel modules and user-space daemon
7
8 # Copyright (C) 2009 Nicira Networks, Inc.
9 #
10 # Licensed under the Apache License, Version 2.0 (the "License");
11 # you may not use this file except in compliance with the License.
12 # You may obtain a copy of the License at:
13 #
14 #     http://www.apache.org/licenses/LICENSE-2.0
15 #
16 # Unless required by applicable law or agreed to in writing, software
17 # distributed under the License is distributed on an "AS IS" BASIS,
18 # WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
19 # See the License for the specific language governing permissions and
20 # limitations under the License.
21
22 . /etc/init.d/functions
23
24 test -e /etc/sysconfig/vswitch && . /etc/sysconfig/vswitch
25
26 # General config variables in /etc/sysconfig/vswitch
27 VSWITCH_BASE="${VSWITCH_BASE:-/root/vswitch}"
28 ENABLE_BRCOMPAT="${ENABLE_BRCOMPAT:-y}"
29 ENABLE_FAKE_PROC_NET="${ENABLE_FAKE_PROC_NET:-y}"
30 FORCE_COREFILES="${FORCE_COREFILES:-y}"
31
32 # Config variables specific to ovs-vswitchd
33 VSWITCHD_CONF="${VSWITCHD_CONF:-/etc/ovs-vswitchd.conf}"
34 VSWITCHD_PIDFILE="${VSWITCHD_PIDFILE:-/var/run/ovs-vswitchd.pid}"
35 VSWITCHD_RUN_DIR="${VSWITCHD_RUN_DIR:-/var/xen/vswitch}"
36 VSWITCHD_PRIORITY="${VSWITCHD_PRIORITY:--5}"
37 VSWITCHD_LOGFILE="${VSWITCHD_LOGFILE:-/var/log/ovs-vswitchd.log}"
38 VSWITCHD_FILE_LOGLEVEL="${VSWITCHD_FILE_LOGLEVEL:-}"
39 VSWITCHD_SYSLOG_LOGLEVEL="${VSWITCHD_SYSLOG_LOGLEVEL:-WARN}"
40 VSWITCHD_MEMLEAK_LOGFILE="${VSWITCHD_MEMLEAK_LOGFILE:-}"
41 VSWITCHD_STRACE_LOG="${VSWITCHD_STRACE_LOG:-}"
42 VSWITCHD_STRACE_OPT="${VSWITCHD_STRACE_OPT:-}"
43 VSWITCHD_VALGRIND_LOG="${VSWITCHD_VALGRIND_LOG:-}"
44 VSWITCHD_VALGRIND_OPT="${VSWITCHD_VALGRIND_OPT:-}"
45
46 # Config variables specific to ovs-brcompatd
47 BRCOMPATD_PIDFILE="${BRCOMPATD_PIDFILE:-/var/run/ovs-brcompatd.pid}"
48 BRCOMPATD_RUN_DIR="${BRCOMPATD_RUN_DIR:-/var/xen/vswitch}"
49 BRCOMPATD_PRIORITY="${BRCOMPATD_PRIORITY:--5}"
50 BRCOMPATD_LOGFILE="${BRCOMPATD_LOGFILE:-/var/log/ovs-brcompatd.log}"
51 BRCOMPATD_FILE_LOGLEVEL="${BRCOMPATD_FILE_LOGLEVEL:-}"
52 BRCOMPATD_SYSLOG_LOGLEVEL="${BRCOMPATD_SYSLOG_LOGLEVEL:-INFO}"
53 BRCOMPATD_MEMLEAK_LOGFILE="${BRCOMPATD_MEMLEAK_LOGFILE:-}"
54 BRCOMPATD_STRACE_LOG="${BRCOMPATD_STRACE_LOG:-}"
55 BRCOMPATD_STRACE_OPT="${BRCOMPATD_STRACE_OPT:-}"
56 BRCOMPATD_VALGRIND_LOG="${BRCOMPATD_VALGRIND_LOG:-}"
57 BRCOMPATD_VALGRIND_OPT="${BRCOMPATD_VALGRIND_OPT:-}"
58
59
60
61
62 # Full paths to executables & modules
63 vswitchd="$VSWITCH_BASE/sbin/ovs-vswitchd"
64 brcompatd="$VSWITCH_BASE/sbin/ovs-brcompatd"
65 dpctl="$VSWITCH_BASE/bin/ovs-dpctl"
66 appctl="$VSWITCH_BASE/bin/ovs-appctl"
67 ofctl="$VSWITCH_BASE/bin/ovs-ofctl"
68
69
70 if [ "$ENABLE_FAKE_PROC_NET" = "y" ]; then
71     if [ "$ENABLE_BRCOMPAT" != "y" ]; then
72         warning "FAKE_PROC_NET required BRCOMPAT which was disabled.  Force enabling."
73         ENABLE_BRCOMPAT="y"
74     fi
75 fi
76
77 function dp_list {
78     "$dpctl" show | grep '^dp[0-9]\+:' | cut -d':' -f 1
79 }
80
81 function turn_on_corefiles {
82     ulimit -Sc 67108864
83 }
84
85 function remove_all_dp {
86     for dp in $(dp_list); do
87         action "Removing datapath: $dp" "$dpctl" del-dp "$dp"
88     done
89 }
90
91 function insert_modules_if_required {
92     if ! lsmod | grep -q "openvswitch_mod"; then
93         action "Inserting llc module" modprobe llc
94         action "Inserting openvswitch module" insmod $VSWITCH_BASE/kernel_modules/openvswitch_mod.ko
95     fi
96     if [ -n "$BRCOMPATD_PIDFILE" ] && ! lsmod | grep -q "brcompat_mod"; then
97         action "Inserting brcompat module" insmod $VSWITCH_BASE/kernel_modules/brcompat_mod.ko
98     fi
99 }
100
101 function remove_modules {
102     if lsmod | grep -q "brcompat_mod"; then
103         action "Removing brcompat module" rmmod brcompat_mod.ko
104     fi
105     if lsmod | grep -q "openvswitch_mod"; then
106         action "Removing openvswitch module" rmmod openvswitch_mod.ko
107     fi
108 }
109
110 function reload_vswitchd {
111     if [ -f "$VSWITCHD_PIDFILE" ]; then
112         "$appctl" \
113             --target=ovs-vswitchd.$(cat "$VSWITCHD_PIDFILE").ctl \
114             --execute=vswitchd/reload
115     fi
116 }
117
118 function start_vswitchd {
119     local syslog_opt="-vANY:SYSLOG:${VSWITCHD_SYSLOG_LOGLEVEL}"
120     local logfile_file_opt=""
121     local logfile_level_opt=""
122     if [ ! -d "$VSWITCHD_RUN_DIR" ]; then
123         mkdir -p "$VSWITCHD_RUN_DIR"
124     fi
125     cd "$VSWITCHD_RUN_DIR"
126     if [ -n "$VSWITCHD_FILE_LOGLEVEL" ]; then
127         logfile_level_opt="-vANY:FILE:${VSWITCHD_FILE_LOGLEVEL}"
128         logfile_file_opt="--log-file=$VSWITCHD_LOGFILE"
129     fi
130     local leak_opt=""
131     if [ -n "$VSWITCHD_MEMLEAK_LOGFILE" ]; then
132         leak_opt="--check-leaks=$VSWITCHD_MEMLEAK_LOGFILE"
133         if [ -e "$VSWITCHD_MEMLEAK_LOGFILE" ]; then
134             mv "$VSWITCHD_MEMLEAK_LOGFILE" "$VSWITCHD_MEMLEAK_LOGFILE.prev"
135         fi
136     fi
137     local strace_opt=""
138     local daemonize="y"
139     if [ -n "$VSWITCHD_STRACE_LOG" ] && [ -n "$VSWITCHD_VALGRIND_LOG" ]; then
140         printf "Can not start with both VALGRIND and STRACE\n"
141         exit 1
142     fi
143     if [ -n "$VSWITCHD_STRACE_LOG" ]; then
144         strace_opt="strace -o $VSWITCHD_STRACE_LOG $VSWITCHD_STRACE_OPT"
145         daemonize="n"
146     fi
147     if [ -n "$VSWITCHD_VALGRIND_LOG" ]; then
148         valgrind_opt="valgrind --log-file=$VSWITCHD_VALGRIND_LOG $VSWITCHD_VALGRIND_OPT"
149         daemonize="n"
150     fi
151     local fake_proc_net_opt=""
152     if [ "$ENABLE_FAKE_PROC_NET" = "y" ]; then
153         fake_proc_net_opt="--fake-proc-net"
154     fi
155     if [ "$daemonize" != "y" ]; then
156         # Start in background and force a "success" message
157         action "Starting ovs-vswitchd ($strace_opt$valgrind_opt)" true
158         (nice -n "$VSWITCHD_PRIORITY" $strace_opt $valgrind_opt "$vswitchd" --pidfile="$VSWITCHD_PIDFILE" --detach --no-chdir $fake_proc_net_opt -vANY:CONSOLE:EMER $syslog_opt $logfile_level_opt $logfile_file_opt $leak_opt "$VSWITCHD_CONF") &
159     else
160         action "Starting ovs-vswitchd" nice -n "$VSWITCHD_PRIORITY" "$vswitchd" --pidfile="$VSWITCHD_PIDFILE" --detach --no-chdir $fake_proc_net_opt -vANY:CONSOLE:EMER $syslog_opt $logfile_level_opt $logfile_file_opt $leak_opt "$VSWITCHD_CONF"
161     fi
162 }
163
164 function start_brcompatd {
165     local syslog_opt="-vANY:SYSLOG:${BRCOMPATD_SYSLOG_LOGLEVEL}"
166     local logfile_file_opt=""
167     local logfile_level_opt=""
168     if [ -d "$BRCOMPATD_RUN_DIR" ]; then
169         mkdir -p "$BRCOMPATD_RUN_DIR"
170     fi
171     cd "$BRCOMPATD_RUN_DIR"
172     if [ ! -n "$BRCOMPATD_FILE_LOGLEVEL" ]; then
173         logfile_level_opt="-vANY:FILE:${BRCOMPATD_FILE_LOGLEVEL}"
174         logfile_file_opt="--log-file=$BRCOMPATD_LOGFILE"
175     fi
176     local leak_opt=""
177     if [ -n "$BRCOMPATD_MEMLEAK_LOG" ]; then
178         leak_opt="--check-leaks=$BRCOMPATD_MEMLEAK_LOGFILE"
179         if [ -e "$BRCOMPATD_MEMLEAK_LOGFILE" ]; then
180             mv "$BRCOMPATD_MEMLEAK_LOGFILE" "$BRCOMPATD_MEMLEAK_LOGFILE.prev"
181         fi
182     fi
183     local strace_opt=""
184     local daemonize="y"
185     if [ -n "$BRCOMPATD_STRACE_LOG" ] && [ -n "$BRCOMPATD_VALGRIND_LOG" ]; then
186         printf "Can not start with both VALGRIND and STRACE\n"
187         exit 1
188     fi
189     if [ -n "$BRCOMPATD_STRACE_LOG" ]; then
190         strace_opt="strace -o $BRCOMPATD_STRACE_LOG $BRCOMPATD_STRACE_OPT"
191         daemonize="n"
192     fi
193     if [ -n "$VALGRIND_LOG" ]; then
194         valgrind_opt="valgrind --log-file=$BRCOMPATD_VALGRIND_LOG $BRCOMPATD_VALGRIND_OPT"
195         daemonize="n"
196     fi
197     appctl_cmd="$appctl -t /var/run/ovs-vswitchd.\`cat $VSWITCHD_PIDFILE\`.ctl -e '%s'"
198     if [ "$daemonize" != "y" ]; then
199         # Start in background and force a "success" message
200         action "Starting ovs-brcompatd ($strace_opt$valgrind_opt)" true
201         (nice -n "$VSWITCHD_PRIORITY" $strace_opt $valgrind_opt "$brcompatd"--no-chdir --appctl-command="$appctl_cmd" --pidfile=$BRCOMPATD_PIDFILE -vANY:CONSOLE:EMER $syslog_opt $logfile_level_opt $logfile_file_opt $leak_opt "$VSWITCHD_CONF") &
202     else
203         action "Starting ovs-brcompatd" nice -n "$BRCOMPATD_PRIORITY" $strace_opt $valgrind_opt "$brcompatd" --no-chdir --appctl-command="$appctl_cmd" --pidfile=$BRCOMPATD_PIDFILE --detach -vANY:CONSOLE:EMER $syslog_opt $logfile_level_opt $logfile_file_opt $leak_opt "$VSWITCHD_CONF"
204     fi
205 }
206
207 function stop_vswitchd {
208     if [ -f "$VSWITCHD_PIDFILE" ]; then
209         local pid=$(cat "$VSWITCHD_PIDFILE")
210         action "Killing ovs-vswitchd ($pid)" kill -TERM $pid
211         rm -f "$VSWITCHD_PIDFILE"
212     fi
213 }
214
215 function stop_brcompatd {
216     if [ -f "$BRCOMPATD_PIDFILE" ]; then
217         local pid=$(cat "$BRCOMPATD_PIDFILE")
218         action "Killing ovs-brcompatd ($pid)" kill -TERM $pid
219         rm -f "$BRCOMPATD_PIDFILE"
220     fi
221 }
222
223 function restart_approval {
224     if test ! -t 0; then
225         # Don't prompt if invoked non-interactively.
226         return 0
227     fi
228     cat <<EOF
229
230 WARNING!!!
231
232 Restarting vswitch on a live server is not guaranteed to work.  It is
233 provided as a convenience for those situations in which it does work.
234 If you just want to reload the configuration file, use "reload"
235 instead of restart.
236
237 EOF
238     read -s -r -n 1 -p "Countinue with restart (y/N): " response
239     printf "\n"
240     case "$response" in
241         y|Y)
242             return 0
243             ;;
244         *)
245             return 1
246             ;;
247     esac
248 }
249
250 function start {
251     if [ "$FORCE_COREFILES" = "y" ]; then
252         turn_on_corefiles
253     fi
254
255     insert_modules_if_required
256
257     # Increase the limit on the number of open file descriptors since
258     # ovs-vswitchd needs a few per bridge
259     ulimit -n 4096
260
261     start_vswitchd
262     start_brcompatd
263     reload_vswitchd  # ensures ovs-vswitchd has fully read config file.
264 }
265
266 function stop {
267     stop_brcompatd
268     stop_vswitchd
269 }
270
271 function restart {
272     if restart_approval; then
273         stop
274         start
275     fi
276 }
277
278 case "$1" in
279     start)
280         start
281         ;;
282     stop)
283         stop
284         ;;
285     restart)
286         restart
287         ;;
288     reload)
289         reload_vswitchd
290         ;;
291     strace-vswitchd)
292         shift
293         strace -p $(cat "$VSWITCHD_PIDFILE") "$@"
294         ;;
295     strace-brcompatd)
296         shift
297         strace -p $(cat "$BRCOMPATD_PIDFILE") "$@"
298         ;;
299     status)
300         status -p ovs-vswitchd.pid ovs-vswitchd
301         status -p ovs-brcompatd.pid ovs-brcompatd
302         ;;
303     version)
304         "$VSWITCH_BASE"/sbin/ovs-vswitchd -V
305         "$VSWITCH_BASE"/sbin/ovs-brcompatd -V
306         ;;
307     help)
308         printf "vswitch [start|stop|restart|reload|unload|status|version]\n"
309         ;;
310     *)
311         printf "Unknown command: $1\n"
312         exit 1