+ slice_attributes = []
+ if slice['slice_attribute_ids']:
+ # Delete unknown attributes
+ for slice_attribute in GetSliceAttributes(slice['slice_attribute_ids']):
+ if (slice_attribute['name'], slice_attribute['value']) \
+ not in default_slice['attributes']:
+ DeleteSliceAttribute(slice_attribute['slice_attribute_id'])
+ else:
+ slice_attributes.append((slice_attribute['name'], slice_attribute['value']))
+
+ for (name, value) in default_slice['attributes']:
+ if (name, value) not in slice_attributes:
+ AddSliceAttribute(slice['name'], name, value)
+
+ installfailed = """
+Once the node meets these requirements, please reinitiate the install
+by visiting:
+
+https://%(PLC_WWW_HOST)s:%(PLC_WWW_SSL_PORT)d/db/nodes/?id=%(node_id)d
+
+Update the BootState to 'Reinstall', then reboot the node.
+
+If you have already performed this step and are still receiving this
+message, please reply so that we may investigate the problem.
+"""
+
+ # Load default message templates
+ message_templates = [
+ {'message_id': 'Verify account',
+ 'subject': "Verify account registration",
+ 'template': """
+Please verify that you registered for a %(PLC_NAME)s account with the
+username %(email)s by visiting:
+
+https://%(PLC_WWW_HOST)s:%(PLC_WWW_SSL_PORT)d/db/persons/register.php?id=%(person_id)d&key=%(verification_key)s
+
+If you did not register for a %(PLC_NAME)s account, please ignore this
+message, or contact %(PLC_NAME)s Support <%(PLC_MAIL_SUPPORT_ADDRESS)s>.
+"""
+ },
+
+ {'message_id': 'New PI account',
+ 'subject': "New PI account registration from %(first_name)s %(last_name)s <%(email)s> at %(site_name)s",
+ 'template': """
+%(first_name)s %(last_name)s <%(email)s> has signed up for a new
+%(PLC_NAME)s account at %(site_name)s and has requested a PI role. PIs
+are responsible for enabling user accounts, creating slices, and
+ensuring that all users abide by the %(PLC_NAME)s Acceptable Use
+Policy.
+
+Only %(PLC_NAME)s administrators may enable new PI accounts. If you
+are a PI at %(site_name)s, please respond and indicate whether this
+registration is acceptable.
+
+To view the request, visit:
+
+https://%(PLC_WWW_HOST)s:%(PLC_WWW_SSL_PORT)d/db/persons/index.php?id=%(person_id)d
+"""
+ },
+
+ {'message_id': 'New account',
+ 'subject': "New account registration from %(first_name)s %(last_name)s <%(email)s> at %(site_name)s",
+ 'template': """
+%(first_name)s %(last_name)s <%(email)s> has signed up for a new
+%(PLC_NAME)s account at %(site_name)s and has requested the following
+roles: %(roles)s.
+
+To deny the request or enable the account, visit:
+
+https://%(PLC_WWW_HOST)s:%(PLC_WWW_SSL_PORT)d/db/persons/index.php?id=%(person_id)d
+"""
+ },
+
+ {'message_id': 'Password reset requested',
+ 'subject': "Password reset requested",
+ 'template': """
+Someone has requested that the password of your %(PLC_NAME)s account
+%(email)s be reset. If this person was you, you may continue with the
+reset by visiting:
+
+https://%(PLC_WWW_HOST)s:%(PLC_WWW_SSL_PORT)d/db/persons/reset_password.php?id=%(person_id)d&key=%(verification_key)s
+
+If you did not request that your password be reset, please contact
+%(PLC_NAME)s Support <%(PLC_MAIL_SUPPORT_ADDRESS)s>. Do not quote or
+otherwise include any of this text in any correspondence.
+"""
+ },
+
+ {'message_id': 'Password reset',
+ 'subject': "Password reset",
+ 'template': """
+The password of your %(PLC_NAME)s account %(email)s has been
+temporarily reset to:
+
+%(password)s
+
+Please change it at as soon as possible by visiting:
+
+https://%(PLC_WWW_HOST)s:%(PLC_WWW_SSL_PORT)d/db/persons/index.php?id=%(person_id)d
+
+If you did not request that your password be reset, please contact
+%(PLC_NAME)s Support <%(PLC_MAIL_SUPPORT_ADDRESS)s>. Do not quote or
+otherwise include any of this text in any correspondence.
+"""
+ },
+
+ # Boot Manager messages
+ {'message_id': "installfinished",
+ 'subject': "%(hostname)s completed installation",
+ 'template': """
+%(hostname)s just completed installation.
+
+The node should be usable in a couple of minutes if installation was
+successful.
+"""
+ },
+
+ {'message_id': "insufficientdisk",
+ 'subject': "%(hostname)s does not have sufficient disk space",
+ 'template': """
+%(hostname)s failed to boot because it does not have sufficent disk
+space, or because its disk controller was not recognized.
+
+Please replace the current disk or disk controller or install
+additional disks to meet the current hardware requirements.
+""" + installfailed
+ },
+
+ {'message_id': "insufficientmemory",
+ 'subject': "%(hostname)s does not have sufficient memory",
+ 'template': """
+%(hostname)s failed to boot because it does not have sufficent
+memory.
+
+Please install additional memory to meet the current hardware
+requirements.
+""" + installfailed
+ },
+
+ {'message_id': "authfail",
+ 'subject': "%(hostname)s failed to authenticate",
+ 'template':
+"""
+%(hostname)s failed to authenticate for the following reason:
+
+%(fault)s
+
+The most common reason for authentication failure is that the
+authentication key stored in the node configuration file, does not
+match the key on record.
+
+There are two possible steps to resolve the problem.
+
+1. If you have used an All-in-one BootCD that includes the plnode.txt file,
+ then please check your machine for any old boot media, either in the
+ floppy drive, or on a USB stick. It is likely that an old configuration
+ is being used instead of the new configuration stored on the BootCD.
+Or,
+2. If you are using Generic BootCD image, then regenerate the node
+ configuration file by visiting:
+
+ https://%(PLC_WWW_HOST)s:%(PLC_WWW_SSL_PORT)d/db/nodes/?id=%(node_id)d
+
+ Under 'Download', follow the 'Download plnode.txt file for %(hostname)s'
+ option, and save the downloaded file as plnode.txt on either a floppy
+ disk or a USB flash drive. Be sure the 'Boot State' is set to 'Boot',
+ and, then reboot the node.
+
+If you have already performed this step and are still receiving this
+message, please reply so that we can help investigate the problem.
+"""
+ },
+
+ {'message_id': "notinstalled",
+ 'subject': "%(hostname)s is not installed",
+ 'template':
+"""
+%(hostname)s failed to boot because it has either never been
+installed, or the installation is corrupt.
+
+Please check if the hard drive has failed, and replace it if so. After
+doing so, visit:
+
+https://%(PLC_WWW_HOST)s:%(PLC_WWW_SSL_PORT)d/db/nodes/?id=%(node_id)d
+
+Change the 'Boot State' to 'Reinstall', and then reboot the node.
+
+If you have already performed this step and are still receiving this
+message, please reply so that we may investigate the problem.
+"""
+ },
+
+ {'message_id': "hostnamenotresolve",
+ 'subject': "%(hostname)s does not resolve",
+ 'template':
+"""
+%(hostname)s failed to boot because its hostname does not resolve, or
+does resolve but does not match its configured IP address.
+
+Please check the network settings for the node, especially its
+hostname, IP address, and DNS servers, by visiting:
+
+https://%(PLC_WWW_HOST)s:%(PLC_WWW_SSL_PORT)d/db/nodes/?id=%(node_id)d
+
+Correct any errors, and change the 'Boot State' to 'Reinstall', and then
+reboot the node.
+
+If you have already performed this step and are still receiving this
+message, please reply so that we may investigate the problem.
+"""
+ },
+
+ # XXX N.B. I don't think these are necessary, since there's no
+ # way that the Boot Manager would even be able to contact the
+ # API to send these messages.
+
+ {'message_id': "noconfig",
+ 'subject': "%(hostname)s does not have a configuration file",
+ 'template': """
+%(hostname)s failed to boot because it could not find a PlanetLab
+configuration file. To create this file, visit:
+
+https://%(PLC_WWW_HOST)s:%(PLC_WWW_SSL_PORT)d/db/nodes/?id=%(node_id)d
+
+Click the Configuration File link, and save the downloaded file as
+plnode.txt on either a floppy disk or a USB flash drive. Change the
+'Boot State' to 'Reinstall', and then reboot the node.
+
+If you have already performed this step and are still receiving this
+message, please reply so that we may investigate the problem.
+"""
+ },
+
+ {'message_id': "nodetectednetwork",
+ 'subject': "%(hostname)s has unsupported network hardware",
+ 'template':
+"""
+
+%(hostname)s failed to boot because it has network hardware that is
+unsupported by the current production kernel. If it has booted
+successfully in the past, please try re-installing it by visiting:
+
+https://%(PLC_WWW_HOST)s:%(PLC_WWW_SSL_PORT)d/db/nodes/?id=%(node_id)d
+
+Change the 'Boot State' to 'Reinstall', and then reboot the node.
+
+If you have already performed this step and are still receiving this
+message, please reply so that we may investigate the problem.
+"""
+ },
+ ]
+
+ for template in message_templates:
+ messages = GetMessages([template['message_id']])
+ if not messages:
+ AddMessage(template)
+
+
+ ### Setup Initial PCU information
+ pcu_types = [{'model': 'AP79xx',
+ 'name': 'APC AP79xx',
+ 'pcu_protocol_types': [{ 'port': 80,
+ 'protocol': 'APC79xxHttp',
+ 'supported': False},
+ { 'port': 23,
+ 'protocol': 'APC79xx',
+ 'supported': True},
+ { 'port': 22,
+ 'protocol': 'APC79xx',
+ 'supported': True}],
+ },
+ {'model': 'Masterswitch',
+ 'name': 'APC Masterswitch',
+ 'pcu_protocol_types': [{ 'port': 80,
+ 'protocol': 'APCMasterHttp',
+ 'supported': False},
+ { 'port': 23,
+ 'protocol': 'APCMaster',
+ 'supported': True},
+ { 'port': 22,
+ 'protocol': 'APCMaster',
+ 'supported': True}],
+ },
+ {'model': 'DS4-RPC',
+ 'name': 'BayTech DS4-RPC',
+ 'pcu_protocol_types': [{ 'port': 80,
+ 'protocol': 'BayTechHttp',
+ 'supported': False},
+ { 'port': 23,
+ 'protocol': 'BayTech',
+ 'supported': True},
+ { 'port': 22,
+ 'protocol': 'BayTech',
+ 'supported': True}],
+ },
+ {'model': 'IP-41x_IP-81x',
+ 'name': 'Dataprobe IP-41x & IP-81x',
+ 'pcu_protocol_types': [ { 'port': 23,
+ 'protocol': 'IPALTelnet',
+ 'supported': True},
+ { 'port': 80,
+ 'protocol': 'IPALHttp',
+ 'supported': False}],
+ },
+ {'model': 'DRAC3',
+ 'name': 'Dell RAC Version 3',
+ 'pcu_protocol_types': [],
+ },
+ {'model': 'DRAC4',
+ 'name': 'Dell RAC Version 4',
+ 'pcu_protocol_types': [{ 'port': 443,
+ 'protocol': 'DRACRacAdm',
+ 'supported': True},
+ { 'port': 80,
+ 'protocol': 'DRACRacAdm',
+ 'supported': False},
+ { 'port': 22,
+ 'protocol': 'DRAC',
+ 'supported': True}],
+ },
+ {'model': 'ePowerSwitch',
+ 'name': 'ePowerSwitch 1/4/8x',
+ 'pcu_protocol_types': [{ 'port': 80,
+ 'protocol': 'ePowerSwitch',
+ 'supported': True}],
+ },
+ {'model': 'ilo2',
+ 'name': 'HP iLO2 (Integrated Lights-Out)',
+ 'pcu_protocol_types': [{ 'port': 443,
+ 'protocol': 'HPiLOHttps',
+ 'supported': True},
+ { 'port': 22,
+ 'protocol': 'HPiLO',
+ 'supported': True}],
+ },
+ {'model': 'ilo1',
+ 'name': 'HP iLO version 1',
+ 'pcu_protocol_types': [],
+ },
+ {'model': 'PM211-MIP',
+ 'name': 'Infratec PM221-MIP',
+ 'pcu_protocol_types': [],
+ },
+ {'model': 'AMT2.5',
+ 'name': 'Intel AMT v2.5 (Active Management Technology)',
+ 'pcu_protocol_types': [],
+ },
+ {'model': 'AMT3.0',
+ 'name': 'Intel AMT v3.0 (Active Management Technology)',
+ 'pcu_protocol_types': [],
+ },
+ {'model': 'WTI_IPS-4',
+ 'name': 'Western Telematic (WTI IPS-4)',
+ 'pcu_protocol_types': [],
+ },
+ {'model': 'unknown',
+ 'name': 'Unknown Vendor or Model',
+ 'pcu_protocol_types': [{ 'port': 443,
+ 'protocol': 'UnknownPCU',
+ 'supported': False},
+ { 'port': 80,
+ 'protocol': 'UnknownPCU',
+ 'supported': False},
+ { 'port': 23,
+ 'protocol': 'UnknownPCU',
+ 'supported': False},
+ { 'port': 22,
+ 'protocol': 'UnknownPCU',
+ 'supported': False}],
+ }]
+
+ # Get all model names
+ pcu_models = [type['model'] for type in GetPCUTypes()]
+ for type in pcu_types:
+ protocol_types = type['pcu_protocol_types']
+ # Take this value out of the struct.
+ del type['pcu_protocol_types']
+ if type['model'] not in pcu_models:
+ # Add the name/model info into DB
+ id = AddPCUType(type)
+ # for each protocol, also add this.
+ for ptype in protocol_types:
+ AddPCUProtocolType(id, ptype)