- /* Accept AR requests from all nodes */
- reg_write(ohci, OHCI1394_AsReqFilterHiSet, 0x80000000);
-
- /* Set the address range of the physical response unit.
- * Most controllers do not implement it as a writable register though.
- * They will keep a hardwired offset of 0x00010000 and show 0x0 as
- * register content.
- * To actually enable physical responses is the job of our interrupt
- * handler which programs the physical request filter. */
- reg_write(ohci, OHCI1394_PhyUpperBound,
- OHCI1394_PHYS_UPPER_BOUND_PROGRAMMED >> 16);
-
- DBGMSG("physUpperBoundOffset=%08x",
- reg_read(ohci, OHCI1394_PhyUpperBound));
+ /*
+ * Accept AT requests from all nodes. This probably
+ * will have to be controlled from the subsystem
+ * on a per node basis.
+ */
+ reg_write(ohci,OHCI1394_AsReqFilterHiSet, 0x80000000);