+.IP "\fBmod\-table \fIswitch\fR \fItable_id\fR \fIflow_miss_handling\fR"
+An OpenFlow 1.0 switch looks up each packet that arrives at the switch
+in table 0, then in table 1 if there is no match in table 0, then in
+table 2, and so on until the packet finds a match in some table.
+Finally, if no match was found, the switch sends the packet to the
+controller
+.IP
+OpenFlow 1.1 and later offer more flexibility. This command
+configures the flow table miss handling configuration for table
+\fItable_id\fR in \fIswitch\fR. \fItable_id\fR may be an OpenFlow
+table number between 0 and 254, inclusive, or the keyword \fBALL\fR to
+modify all tables. \fIflow_miss_handling\fR may be any one of the
+following:
+.RS
+.IP \fBdrop\fR
+Drop the packet.
+.IP \fBcontinue\fR
+Continue to the next table in the pipeline. (This is how an OpenFlow
+1.0 switch always handles packets that do not match any flow, in
+tables other than the last one.)
+.IP \fBcontroller\fR
+Send to controller. (This is how an OpenFlow 1.0 switch always
+handles packets that do not match any flow in the last table.)
+.RE
+.
+.SS "OpenFlow 1.3+ Switch Meter Table Commands"
+.
+These commands manage the meter table in an OpenFlow switch. In each
+case, \fImeter\fR specifies a meter entry in the format described in
+\fBMeter Syntax\fR, below.
+.
+.PP
+OpenFlow 1.3 introduced support for meters, so these commands only
+work with switches that support OpenFlow 1.3 or later. The caveats
+described for groups in the previous section also apply to meters.
+.
+.IP "\fBadd\-meter \fIswitch meter\fR"
+Add a meter entry to \fIswitch\fR's tables. The \fImeter\fR syntax is
+described in section \fBMeter Syntax\fR, below.
+.
+.IP "\fBmod\-meter \fIswitch meter\fR"
+Modify an existing meter.
+.
+.IP "\fBdel\-meters \fIswitch\fR"
+.IQ "\fBdel\-meter \fIswitch\fR [\fImeter\fR]"
+Delete entries from \fIswitch\fR's meter table. \fImeter\fR can specify
+a single meter with syntax \fBmeter=\fIid\fR, or all meters with syntax
+\fBmeter=all\fR.
+.
+.IP "\fBdump\-meters \fIswitch\fR"
+.IQ "\fBdump\-meter \fIswitch\fR [\fImeter\fR]"
+Print meter configuration. \fImeter\fR can specify a single meter with
+syntax \fBmeter=\fIid\fR, or all meters with syntax \fBmeter=all\fR.
+.
+.IP "\fBmeter\-stats \fIswitch\fR [\fImeter\fR]"
+Print meter statistics. \fImeter\fR can specify a single meter with
+syntax \fBmeter=\fIid\fR, or all meters with syntax \fBmeter=all\fR.
+.
+.IP "\fBmeter\-features \fIswitch\fR"
+Print meter features.
+.