# Proper operations
{'name': "proper_op",
'description': "Proper operation (e.g. bind_socket)",
- 'min_role_id': 10},
-
- # XXX Required for old Node Manager
- # Special attributes applicable to Slice Creation Service (pl_conf) slice
- {'name': "plc_slice_type",
- 'description': "Type of slice rspec to be created",
- 'min_role_id': 20},
- {'name': "plc_agent_version",
- 'description': "Version of PLC agent (slice creation service) software to be deployed",
- 'min_role_id': 10},
- {'name': "plc_ticket_pubkey",
- 'description': "Public key used to verify PLC-signed tickets",
'min_role_id': 10}
]
UpdateSliceAttributeType(default_attribute_type['name'], default_attribute_type)
# Create/update system slices
- legacy_slices = [
- # XXX Required for old Node Manager
- {'name': "pl_conf",
- 'description': "PlanetLab Slice Creation Service (SCS)",
- 'url': url,
- 'instantiation': "plc-instantiated",
- # Renew forever
- 'expires': sys.maxint,
- 'attributes': [('plc_slice_type', "VServerSlice"),
- ('plc_agent_version', "1.0"),
- ('plc_ticket_pubkey', "")]},
-
- # XXX Required for old Node Manager
- {'name': "pl_conf_vserverslice",
- 'description': "Default attributes for vserver slices",
- 'url': url,
- 'instantiation': "plc-instantiated",
- # Renew forever
- 'expires': sys.maxint,
- 'attributes': [('cpu_share', "32"),
- ('plc_slice_type', "VServerSlice"),
- ('disk_max', "5000000")]},
- ]
default_slices = [
# PlanetFlow
{'name': plc['slice_prefix'] + "_netflow",
('proper_op', "create_socket"),
('proper_op', "bind_socket")]},
]
-
- ### xxx - to review once new node manager rolls out
- # if PLC_SLICE_PREFIX is left to default - this is meant for the public PL only
- if plc['slice_prefix'] == 'pl':
- # create both legacy slices together with netflow through default_slices
- default_slices += legacy_slices
- else:
- # we use another slice prefix : disable legacy slices if already created
- for legacy_slice in legacy_slices:
- try:
- DeleteSlice(legacy_slice['name'])
- except:
- pass
for default_slice in default_slices:
slices = GetSlices([default_slice['name']])
if not messages:
AddMessage(template)
+
+ ### Setup Initial PCU information
+ pcu_types = [{'model': 'AP79xx',
+ 'name': 'APC AP79xx',
+ 'pcu_protocol_types': [{ 'port': 80,
+ 'protocol': 'APC79xxHttp',
+ 'supported': False},
+ { 'port': 23,
+ 'protocol': 'APC79xx',
+ 'supported': True},
+ { 'port': 22,
+ 'protocol': 'APC79xx',
+ 'supported': True}],
+ },
+ {'model': 'Masterswitch',
+ 'name': 'APC Masterswitch',
+ 'pcu_protocol_types': [{ 'port': 80,
+ 'protocol': 'APCMasterHttp',
+ 'supported': False},
+ { 'port': 23,
+ 'protocol': 'APCMaster',
+ 'supported': True},
+ { 'port': 22,
+ 'protocol': 'APCMaster',
+ 'supported': True}],
+ },
+ {'model': 'DS4-RPC',
+ 'name': 'BayTech DS4-RPC',
+ 'pcu_protocol_types': [{ 'port': 80,
+ 'protocol': 'BayTechHttp',
+ 'supported': False},
+ { 'port': 23,
+ 'protocol': 'BayTech',
+ 'supported': True},
+ { 'port': 22,
+ 'protocol': 'BayTech',
+ 'supported': True}],
+ },
+ {'model': 'IP-41x_IP-81x',
+ 'name': 'Dataprobe IP-41x & IP-81x',
+ 'pcu_protocol_types': [ { 'port': 23,
+ 'protocol': 'IPALTelnet',
+ 'supported': True},
+ { 'port': 80,
+ 'protocol': 'IPALHttp',
+ 'supported': False}],
+ },
+ {'model': 'DRAC3',
+ 'name': 'Dell RAC Version 3',
+ 'pcu_protocol_types': [],
+ },
+ {'model': 'DRAC4',
+ 'name': 'Dell RAC Version 4',
+ 'pcu_protocol_types': [{ 'port': 443,
+ 'protocol': 'DRACRacAdm',
+ 'supported': True},
+ { 'port': 80,
+ 'protocol': 'DRACRacAdm',
+ 'supported': False},
+ { 'port': 22,
+ 'protocol': 'DRAC',
+ 'supported': True}],
+ },
+ {'model': 'ePowerSwitch',
+ 'name': 'ePowerSwitch 1/4/8x',
+ 'pcu_protocol_types': [{ 'port': 80,
+ 'protocol': 'ePowerSwitch',
+ 'supported': True}],
+ },
+ {'model': 'ilo2',
+ 'name': 'HP iLO2 (Integrated Lights-Out)',
+ 'pcu_protocol_types': [{ 'port': 443,
+ 'protocol': 'HPiLOHttps',
+ 'supported': True},
+ { 'port': 22,
+ 'protocol': 'HPiLO',
+ 'supported': True}],
+ },
+ {'model': 'ilo1',
+ 'name': 'HP iLO version 1',
+ 'pcu_protocol_types': [],
+ },
+ {'model': 'PM211-MIP',
+ 'name': 'Infratec PM221-MIP',
+ 'pcu_protocol_types': [],
+ },
+ {'model': 'AMT2.5',
+ 'name': 'Intel AMT v2.5 (Active Management Technology)',
+ 'pcu_protocol_types': [],
+ },
+ {'model': 'AMT3.0',
+ 'name': 'Intel AMT v3.0 (Active Management Technology)',
+ 'pcu_protocol_types': [],
+ },
+ {'model': 'WTI_IPS-4',
+ 'name': 'Western Telematic (WTI IPS-4)',
+ 'pcu_protocol_types': [],
+ },
+ {'model': 'unknown',
+ 'name': 'Unknown Vendor or Model',
+ 'pcu_protocol_types': [{ 'port': 443,
+ 'protocol': 'UnknownPCU',
+ 'supported': False},
+ { 'port': 80,
+ 'protocol': 'UnknownPCU',
+ 'supported': False},
+ { 'port': 23,
+ 'protocol': 'UnknownPCU',
+ 'supported': False},
+ { 'port': 22,
+ 'protocol': 'UnknownPCU',
+ 'supported': False}],
+ }]
+
+ # Get all model names
+ pcu_models = [type['model'] for type in GetPCUTypes()]
+ for type in pcu_types:
+ protocol_types = type['pcu_protocol_types']
+ # Take this value out of the struct.
+ del type['pcu_protocol_types']
+ if type['model'] not in pcu_models:
+ # Add the name/model info into DB
+ id = AddPCUType(type)
+ # for each protocol, also add this.
+ for ptype in protocol_types:
+ AddPCUProtocolType(id, ptype)
+
+
if __name__ == '__main__':
main()