* efi.get_next_variable() is only called from efivars_init(),
* which is protected by the BKL, so that path is safe.
*/
-static spinlock_t efivars_lock = SPIN_LOCK_UNLOCKED;
+static DEFINE_SPINLOCK(efivars_lock);
static LIST_HEAD(efivar_list);
/*
#define EFI_ATTR(_name, _mode, _show, _store) \
struct subsys_attribute efi_attr_##_name = { \
- .attr {.name = __stringify(_name), .mode = _mode, .owner = THIS_MODULE}, \
+ .attr = {.name = __stringify(_name), .mode = _mode, .owner = THIS_MODULE}, \
.show = _show, \
.store = _store, \
};
*(short_name + strlen(short_name)) = '-';
efi_guid_unparse(vendor_guid, short_name + strlen(short_name));
- kobject_set_name(&new_efivar->kobj, short_name);
+ kobject_set_name(&new_efivar->kobj, "%s", short_name);
kobj_set_kset_s(new_efivar, vars_subsys);
kobject_register(&new_efivar->kobj);