vserver 1.9.5.x5
[linux-2.6.git] / drivers / mtd / maps / Kconfig
index 7b6da6a..f00f24f 100644 (file)
@@ -1,5 +1,5 @@
 # drivers/mtd/maps/Kconfig
-# $Id: Kconfig,v 1.12 2003/06/23 07:38:11 dwmw2 Exp $
+# $Id: Kconfig,v 1.42 2005/01/05 16:59:50 dwmw2 Exp $
 
 menu "Mapping drivers for chip access"
        depends on MTD!=n
@@ -19,7 +19,8 @@ config MTD_PHYSMAP
          command set driver code to communicate with flash chips which
          are mapped physically into the CPU's memory. You will need to
          configure the physical address and size of the flash chips on
-         your particular board as well as the bus width.
+         your particular board as well as the bus width, either statically
+         with config options or at run-time.
 
 config MTD_PHYSMAP_START
        hex "Physical start address of flash mapping"
@@ -30,6 +31,8 @@ config MTD_PHYSMAP_START
          are mapped on your particular target board. Refer to the
          memory map which should hopefully be in the documentation for
          your board.
+         Ignore this option if you use run-time physmap configuration
+         (i.e., run-time calling physmap_configure()).
 
 config MTD_PHYSMAP_LEN
        hex "Physical length of flash mapping"
@@ -42,9 +45,11 @@ config MTD_PHYSMAP_LEN
          than the total amount of flash present. Refer to the memory
          map which should hopefully be in the documentation for your
          board.
+         Ignore this option if you use run-time physmap configuration
+         (i.e., run-time calling physmap_configure()).
 
-config MTD_PHYSMAP_BUSWIDTH
-       int "Bus width in octets"
+config MTD_PHYSMAP_BANKWIDTH
+       int "Bank width in octets"
        depends on MTD_PHYSMAP
        default "2"
        help
@@ -52,6 +57,8 @@ config MTD_PHYSMAP_BUSWIDTH
          in octets. For example, if you have a data bus width of 32
          bits, you would set the bus width octect value to 4. This is
          used internally by the CFI drivers.
+         Ignore this option if you use run-time physmap configuration
+         (i.e., run-time calling physmap_configure()).
 
 config MTD_SUN_UFLASH
        tristate "Sun Microsystems userflash support"
@@ -85,6 +92,25 @@ config MTD_NETSC520
          demonstration board. If you have one of these boards and would like 
          to use the flash chips on it, say 'Y'.
 
+config MTD_TS5500
+       tristate "JEDEC Flash device mapped on Technologic Systems TS-5500"
+       depends on X86 && MTD_JEDECPROBE && MTD_PARTITIONS
+       help
+         This provides a driver for the on-board flash of the Technologic
+         System's TS-5500 board. The flash is split into 3 partitions
+         which are accessed as separate MTD devices.
+
+         mtd0 and mtd2 are the two BIOS drives. Unfortunately the BIOS
+         uses a proprietary flash translation layer from General Software,
+         which is not supported (the drives cannot be mounted). You can
+         create your own file system (jffs for example), but the BIOS
+         won't be able to boot from it.
+
+         mtd1 allows you to reprogram your BIOS. BE VERY CAREFUL.
+
+         Note that jumper 3 ("Write Enable Drive A") must be set
+         otherwise detection won't succeeed.
+
 config MTD_SBC_GXX
        tristate "CFI Flash device mapped on Arcom SBC-GXx boards"
        depends on X86 && MTD_CFI_INTELEXT && MTD_PARTITIONS && MTD_COMPLEX_MAPPINGS
@@ -133,7 +159,7 @@ config MTD_VMAX
 
 config MTD_SCx200_DOCFLASH
        tristate "Flash device mapped with DOCCS on NatSemi SCx200"
-       depends on X86 && MTD_CFI
+       depends on X86 && MTD_CFI && MTD_PARTITIONS
        help
          Enable support for a flash chip mapped using the DOCCS signal on a
          National Semiconductor SCx200 processor.
@@ -151,11 +177,11 @@ config MTD_AMD76XROM
 
          BE VERY CAREFUL.
 
-config MTD_ICH2ROM
-       tristate "BIOS flash chip on Intel Hub Controller 2"
-       depends on X86 && MTD_JEDECPROBE && MTD_COMPLEX_MAPPINGS
+config MTD_ICHXROM
+       tristate "BIOS flash chip on Intel Controller Hub 2/3/4/5"
+       depends on X86 && MTD_JEDECPROBE
        help
-         Support for treating the BIOS flash chip on ICH2 motherboards
+         Support for treating the BIOS flash chip on ICHX motherboards
          as an MTD device - with this you can reprogram your BIOS.
 
          BE VERY CAREFUL.
@@ -177,7 +203,7 @@ config MTD_TSUNAMI
 
 config MTD_LASAT
        tristate "Flash chips on LASAT board"
-       depends on LASAT && MTD_CFI
+       depends on LASAT
        help
          Support for the flash chips on the Lasat 100 and 200 boards.
 
@@ -210,6 +236,52 @@ config MTD_PB1XXX_USER
          You can say 'Y' to both this and 'MTD_PB1XXX_BOOT' above, to use
          both banks.
 
+config MTD_PB1550
+       tristate "Flash devices on Alchemy PB1550 board"
+       depends on MIPS && MIPS_PB1550
+       help
+         Flash memory access on Alchemy Pb1550 board
+
+config MTD_PB1550_BOOT
+       bool "PB1550 boot flash device"
+       depends on MTD_PB1550
+       help
+         Use the first of the two 64MiB flash banks on Pb1550 board.
+         You can say 'Y' to both this and 'MTD_PB1550_USER' below, to use
+         both banks.
+
+config MTD_PB1550_USER
+       bool "PB1550 user flash device"
+       depends on MTD_PB1550
+       default y if MTD_PB1550_BOOT = n
+       help
+         Use the second of the two 64MiB flash banks on Pb1550 board.
+         You can say 'Y' to both this and 'MTD_PB1550_BOOT' above, to use
+         both banks.
+
+config MTD_DB1550
+       tristate "Flash devices on Alchemy DB1550 board"
+       depends on MIPS && MIPS_DB1550
+       help
+         Flash memory access on Alchemy Db1550 board
+
+config MTD_DB1550_BOOT
+       bool "DB1550 boot flash device"
+       depends on MTD_DB1550
+       help
+         Use the first of the two 64MiB flash banks on Db1550 board.
+         You can say 'Y' to both this and 'MTD_DB1550_USER' below, to use
+         both banks.
+
+config MTD_DB1550_USER
+       bool "DB1550 user flash device"
+       depends on MTD_DB1550
+       default y if MTD_DB1550_BOOT = n
+       help
+         Use the second of the two 64MiB flash banks on Db1550 board.
+         You can say 'Y' to both this and 'MTD_DB1550_BOOT' above, to use
+         both banks.
+
 config MTD_DILNETPC
        tristate "CFI Flash device mapped on DIL/Net PC"
        depends on X86 && MTD_CONCAT && MTD_PARTITIONS && MTD_CFI_INTELEXT
@@ -235,6 +307,13 @@ config MTD_L440GX
 
          BE VERY CAREFUL.
 
+config MTD_SBC8240
+       tristate "Flash device on SBC8240"
+       depends on PPC32 && MTD_JEDECPROBE && 6xx && 8260
+       help
+          Flash access on the SBC8240 board from Wind River.  See
+          <http://www.windriver.com/products/sbc8240/>
+
 config MTD_TQM8XXL
        tristate "CFI Flash device mapped on TQM8XXL"
        depends on MTD_CFI && PPC32 && 8xx && TQM8xxL
@@ -265,7 +344,7 @@ config MTD_MBX860
 
 config MTD_DBOX2
        tristate "CFI Flash device mapped on D-Box2"
-       depends on PPC32 && 8xx && MTD_CFI_INTELSTD && MTD_CFI_INTELEXT && MTD_CFI_AMDSTD
+       depends on PPC32 && 8xx && DBOX2 && MTD_CFI_INTELSTD && MTD_CFI_INTELEXT && MTD_CFI_AMDSTD
        help
          This enables access routines for the flash chips on the Nokia/Sagem
          D-Box 2 board. If you have one of these boards and would like to use
@@ -275,7 +354,7 @@ config MTD_CFI_FLAGADM
        tristate "CFI Flash device mapping on FlagaDM"
        depends on PPC32 && 8xx && MTD_CFI
        help
-         Mapping for the Flaga digital module. If you donยดt have one, ignore
+         Mapping for the Flaga digital module. If you don't have one, ignore
          this setting.
 
 config MTD_BEECH
@@ -294,14 +373,30 @@ config MTD_ARCTIC
          Arctic board. If you have one of these boards and would like to
          use the flash chips on it, say 'Y'.
 
+config MTD_WALNUT
+       tristate "Flash device mapped on IBM 405GP Walnut"
+       depends on MTD_JEDECPROBE && PPC32 && 40x && WALNUT
+       help
+         This enables access routines for the flash chips on the IBM 405GP
+         Walnut board. If you have one of these boards and would like to
+         use the flash chips on it, say 'Y'.
+
 config MTD_EBONY
-       tristate "CFI Flash device mapped on IBM 440GP Ebony"
-       depends on MTD_CFI && PPC32 && 440 && EBONY
+       tristate "Flash devices mapped on IBM 440GP Ebony"
+       depends on MTD_JEDECPROBE && PPC32 && 44x && EBONY
        help
          This enables access routines for the flash chips on the IBM 440GP
          Ebony board. If you have one of these boards and would like to
          use the flash chips on it, say 'Y'.
 
+config MTD_OCOTEA
+       tristate "Flash devices mapped on IBM 440GX Ocotea"
+       depends on MTD_CFI && PPC32 && 44x && OCOTEA
+       help
+         This enables access routines for the flash chips on the IBM 440GX
+         Ocotea board. If you have one of these boards and would like to
+         use the flash chips on it, say 'Y'.
+
 config MTD_REDWOOD
        tristate "CFI Flash devices mapped on IBM Redwood"
        depends on MTD_CFI && PPC32 && 4xx && 40x && ( REDWOOD_4 || REDWOOD_5 || REDWOOD_6 )
@@ -310,11 +405,19 @@ config MTD_REDWOOD
          Redwood board. If you have one of these boards and would like to
          use the flash chips on it, say 'Y'.
 
+config MTD_CHESTNUT
+       tristate "CFI Flash devices mapped on IBM 750FX or IBM 750GX Eval Boards"
+       depends on MTD_CFI && PPC32 && CHESTNUT && MTD_PARTITIONS
+       help
+         This enables access routines for the flash chips on the IBM
+         750FX and 750GX Eval Boards. If you have one of these boards and
+         would like to use the flash chips on it, say 'Y'
+
 config MTD_CSTM_MIPS_IXX
        tristate "Flash chip mapping on ITE QED-4N-S01B, Globespan IVR or custom board"
        depends on MIPS && MTD_CFI && MTD_JEDECPROBE && MTD_PARTITIONS
        help
-         This provides a mapping driver for the Integrated Tecnology
+         This provides a mapping driver for the Integrated Technology
          Express, Inc (ITE) QED-4N-S01B eval board and the Globespan IVR
          Reference Board. It provides the necessary addressing, length,
          buswidth, vpp code and addition setup of the flash device for
@@ -388,6 +491,12 @@ config MTD_SA1100
          the SA1100 and SA1110, including the Assabet and the Compaq iPAQ.
          If you have such a board, say 'Y'.
 
+config MTD_IPAQ
+       tristate "CFI Flash device mapped on Compaq/HP iPAQ"
+       depends on ARM && IPAQ_HANDHELD && MTD_CFI
+       help
+         This provides a driver for the on-board flash of the iPAQ.
+
 config MTD_DC21285
        tristate "CFI Flash device mapped on DC21285 Footbridge"
        depends on ARM && MTD_CFI && ARCH_FOOTBRIDGE && MTD_COMPLEX_MAPPINGS
@@ -404,6 +513,24 @@ config MTD_IQ80310
          IQ80310 evaluation board. If you have one of these boards and would 
          like to use the flash chips on it, say 'Y'.
 
+config MTD_IXP4XX
+       tristate "CFI Flash device mapped on Intel IXP4xx based systems"
+       depends on ARM && MTD_CFI && MTD_COMPLEX_MAPPINGS && ARCH_IXP4XX
+       help
+         This enables MTD access to flash devices on platforms based 
+         on Intel's IXP4xx family of network processors such as the
+         IXDP425 and Coyote. If you have an IXP4xx based board and
+         would like to use the flash chips on it, say 'Y'.
+
+config MTD_IXP2000
+       tristate "CFI Flash device mapped on Intel IXP2000 based systems"
+       depends on ARM && MTD_CFI && MTD_COMPLEX_MAPPINGS && ARCH_IXP2000
+       help
+         This enables MTD access to flash devices on platforms based 
+         on Intel's IXP2000 family of network processors such as the
+         IXDP425 and Coyote. If you have an IXP2000 based board and
+         would like to use the flash chips on it, say 'Y'.
+
 config MTD_EPXA10DB
        tristate "CFI Flash device mapped on Epxa10db"
        depends on ARM && MTD_CFI && MTD_PARTITIONS && ARCH_CAMELOT
@@ -448,6 +575,13 @@ config MTD_CEIVA
          PhotoMax Digital Picture Frame.
          If you have such a device, say 'Y'.
 
+config MTD_NOR_TOTO
+       tristate "NOR Flash device on TOTO board"
+       depends on ARM && ARCH_OMAP && OMAP_TOTO
+       help
+         This enables access to the NOR flash on the Texas Instruments
+         TOTO board.
+
 config MTD_H720X
        tristate "Hynix evaluation board mappings"
        depends on ARM && MTD_CFI && ( ARCH_H7201 || ARCH_H7202 )
@@ -455,6 +589,13 @@ config MTD_H720X
          This enables access to the flash chips on the Hynix evaluation boards.
          If you have such a board, say 'Y'.
 
+config MTD_MPC1211
+       tristate "CFI Flash device mapped on Interface MPC-1211"
+       depends on SUPERH && SH_MPC1211 && MTD_CFI
+       help
+         This enables access to the flash chips on the Interface MPC-1211(CTP/PCI/MPC-SH02).
+         If you have such a board, say 'Y'.
+
 # This needs CFI or JEDEC, depending on the cards found.
 config MTD_PCI
        tristate "PCI MTD driver"
@@ -480,5 +621,51 @@ config MTD_UCLINUX
        help
          Map driver to support image based filesystems for uClinux.
 
+config MTD_WRSBC8260
+       tristate "Map driver for WindRiver PowerQUICC II MPC82xx board"
+       depends on (SBC82xx || SBC8560)
+       select MTD_PARTITIONS
+       select MTD_MAP_BANK_WIDTH_4
+       select MTD_MAP_BANK_WIDTH_1
+       select MTD_CFI_I1
+       select MTD_CFI_I4
+       help
+         Map driver for WindRiver PowerQUICC II MPC82xx board. Drives
+         all three flash regions on CS0, CS1 and CS6 if they are configured
+         correctly by the boot loader.
+
+config MTD_DMV182
+        tristate "Map driver for Dy-4 SVME/DMV-182 board."
+        depends on DMV182
+        select MTD_PARTITIONS
+       select MTD_MAP_BANK_WIDTH_32
+       select MTD_CFI_I8
+       select MTD_CFI_AMDSTD
+        help
+          Map driver for Dy-4 SVME/DMV-182 board.
+
+config MTD_BAST
+       tristate "Map driver for Simtec BAST (EB2410ITX)"
+       depends on ARCH_BAST
+       select MTD_PARTITIONS
+       select MTD_MAP_BANK_WIDTH_16
+       select MTD_JEDECPROBE
+       help
+         Map driver for NOR flash on the Simtec BAST (EB2410ITX).
+
+         Note, this driver *cannot* over-ride the WP link on the
+         board, or currently detect the state of the link.
+
+config MTD_BAST_MAXSIZE
+       int "Maximum size for BAST flash area (MiB)"
+       depends on MTD_BAST
+       default "4"
+
+config MTD_SHARP_SL
+       bool "ROM maped on Sharp SL Series"
+       depends on MTD && ARCH_PXA
+       help
+         This enables access to the flash chip on the Sharp SL Series of PDAs.
+
 endmenu