ovs-ctl: Fix indentation of some headings.
[sliver-openvswitch.git] / utilities / ovs-dpctl.8.in
index 958b817..ee12448 100644 (file)
@@ -24,24 +24,19 @@ that network device to the datapath.
 If \fBovs\-vswitchd\fR(8) is in use, use \fBovs\-vsctl\fR(8) instead
 of \fBovs\-dpctl\fR.
 .PP
-Most \fBovs\-dpctl\fR commands that work with datapaths take an argument
-that specifies the name of the datapath, in one of the following
-forms:
-.so lib/dpif.man
+Most \fBovs\-dpctl\fR commands that work with datapaths take an
+argument that specifies the name of the datapath.  Datapath names take
+the form [\fItype\fB@\fR]\fIname\fR, where \fIname\fR is the network
+device associated with the datapath's local port.  If \fItype\fR is
+given, it specifies the datapath provider of \fIname\fR, otherwise the
+default provider \fBsystem\fR is assumed.
 .PP
 The following commands manage datapaths.
 .
 .TP
 \fBadd\-dp \fIdp\fR [\fInetdev\fR...]
-Creates datapath \fIdp\fR.  The name of the new datapath's local port
-depends on how \fIdp\fR is specified: if it takes the form
-\fBdp\fIN\fR, the local port will be named \fBdp\fIN\fR; otherwise,
-the local port's name will be \fIdp\fR.
-.IP
-This will fail if the host already has 256 datapaths, if a network
-device with the same name as the new datapath's local port already
-exists, or if \fIdp\fR is given in the form \fBdp\fIN\fR
-and a datapath numbered \fIN\fR already exists.
+Creates datapath \fIdp\fR, with a local port also named \fIdp\fR.
+This will fail if a network device \fIdp\fR already exists.
 .IP
 If \fInetdev\fRs are specified, \fBovs\-dpctl\fR adds them to the datapath.
 .
@@ -51,7 +46,7 @@ Deletes datapath \fIdp\fR.  If \fIdp\fR is associated with any network
 devices, they are automatically removed.
 .
 .TP
-\fBadd\-if \fIdp netdev\fR[\fIoption\fR...]...
+\fBadd\-if \fIdp netdev\fR[\fB,\fIoption\fR]...
 Adds each \fInetdev\fR to the set of network devices datapath
 \fIdp\fR monitors, where \fIdp\fR is the name of an existing
 datapath, and \fInetdev\fR is the name of one of the host's
@@ -83,10 +78,12 @@ Removes each \fInetdev\fR from the list of network devices datapath
 Prints the name of each configured datapath on a separate line.
 .
 .TP
-\fBshow \fR[\fIdp\fR...]
+[\fB\-s\fR | \fB\-\-statistics\fR] \fBshow \fR[\fIdp\fR...]
 Prints a summary of configured datapaths, including their datapath
 numbers and a list of ports connected to each datapath.  (The local
-port is identified as port 0.)
+port is identified as port 0.)  If \fB\-s\fR or \fB\-\-statistics\fR
+is specified, then packet and byte counters are also printed for each
+port.
 .IP
 If one or more datapaths are specified, information on only those
 datapaths are displayed.  Otherwise, \fBovs\-dpctl\fR displays information
@@ -109,6 +106,9 @@ not OpenFlow flow entries.  By deleting them, the process that set them
 up may be confused about their disappearance.
 .
 .SH OPTIONS
+.IP "\fB\-s\fR, \fB\-\-statistics\fR"
+Causes the \fBshow\fR command to print packet and byte counters for
+each port within the datapaths that it shows.
 .TP
 \fB\-t\fR, \fB\-\-timeout=\fIsecs\fR
 Limits \fBovs\-dpctl\fR runtime to approximately \fIsecs\fR seconds.  If
@@ -118,34 +118,7 @@ signal.
 .so lib/vlog.man
 .so lib/common.man
 .
-.SH EXAMPLES
-.
-A typical \fBovs\-dpctl\fR command sequence for controlling an
-Open vSwitch kernel module:
-.
-.TP
-\fBovs\-dpctl add\-dp dp0\fR
-Creates datapath number 0.
-.
-.TP
-\fBovs\-dpctl add\-if dp0 eth0 eth1\fR
-Adds two network devices to the new datapath.
-.
-.PP
-At this point one would ordinarily start \fBovs\-openflowd\fR(8) on
-\fBdp0\fR, transforming \fBdp0\fR into an OpenFlow switch.  Then, when
-the switch and the datapath is no longer needed:
-.
-.TP
-\fBovs\-dpctl del\-if dp0 eth0 eth1\fR
-Removes network devices from the datapath.
-.
-.TP
-\fBovs\-dpctl del\-dp dp0\fR
-Deletes the datapath.
-.
 .SH "SEE ALSO"
 .
 .BR ovs\-appctl (8),
-.BR ovs\-openflowd (8),
 .BR ovs\-vswitchd (8)