ofproto: Use 64-bit datapath id and management id (OpenFlow 0.9)
[sliver-openvswitch.git] / utilities / ovs-openflowd.8.in
index 4d1a858..aa27496 100644 (file)
@@ -210,13 +210,13 @@ When controller discovery is not performed, this option has no effect.
 .SS "Networking Options"
 .TP
 \fB--datapath-id=\fIdpid\fR
-Sets \fIdpid\fR, which must consist of exactly 12 hexadecimal digits,
+Sets \fIdpid\fR, which must consist of exactly 16 hexadecimal digits,
 as the datapath ID that the switch will use to identify itself to the
 OpenFlow controller.
 
 If this option is omitted, the default datapath ID is taken from the
 Ethernet address of the datapath's local port (which is typically
-randomly generated).
+randomly generated) in the lower 48 bits and zeros in the upper 16.
 
 .TP
 \fB--mgmt-id=\fImgmtid\fR
@@ -254,7 +254,7 @@ switch waits for a message to be received from the controller for
 controller.  After sending the inactivity probe, if no response is
 received for an additional \fIsecs\fR seconds, the switch
 assumes that the connection has been broken and attempts to reconnect.
-The default is 15 seconds, and the minimum value is 5 seconds.
+The default and the minimum value are both 5 seconds.
 
 When fail-open mode is configured, changing the inactivity probe
 interval also changes the interval before entering fail-open mode (see
@@ -294,15 +294,20 @@ Sets the maximum time between attempts to connect to the controller to
 \fIsecs\fR, which must be at least 1.  The actual interval between
 connection attempts starts at 1 second and doubles on each failing
 attempt until it reaches the maximum.  The default maximum backoff
-time is 15 seconds.
+time is 8 seconds.
 
 .TP
 \fB-l\fR, \fB--listen=\fImethod\fR
-Configures the switch to additionally listen for incoming OpenFlow
-connections for switch management with \fBovs\-ofctl\fR.  The \fImethod\fR
+By default, the switch listens for OpenFlow management connections on a
+Unix domain socket named \fB@RUNDIR@/\fIdatapath\fB.mgmt\fR.  This socket 
+can be used to perform local OpenFlow monitoring and administration with
+tools such as \fBovs\-ofctl\fR.  
+
+This option may be used to override the default listener.  The \fImethod\fR
 must be given as one of the passive OpenFlow connection methods listed
 below.  This option may be specified multiple times to listen to
-multiple connection methods.
+multiple connection methods.  If a single \fImethod\fR of \fBnone\fR is
+used, no listeners will be created.
 
 .RS
 .TP
@@ -411,6 +416,22 @@ Sets the directory searched for remote command execution to
 \fBdirectory\fR.  The default directory is
 \fB@pkgdatadir@/commands\fR.
 
+.SS "Datapath Options"
+.
+.IP "\fB\-\-ports=\fIport\fR[\fB,\fIport\fR...]"
+Ordinarily, \fBovs\-openflowd\fR expects the administrator to create
+the specified \fIdatapath\fR and add ports to it externally with a
+utility such as \fBovs\-dpctl\fR.  However, the userspace switch
+datapath is implemented inside \fBovs\-openflowd\fR itself and does
+not (currently) have any external interface for \fBovs\-dpctl\fR to
+access.  As a stopgap measure, this option specifies one or more ports
+to add to the datapath at \fBovs\-openflowd\fR startup time.  Multiple
+ports may be specified as a comma-separated list or by specifying
+\fB\-\-ports\fR multiple times.
+.IP
+See \fBINSTALL.userspace\fR for more information about userspace
+switching.
+
 .SS "Daemon Options"
 .so lib/daemon.man