ovs-vsctl: Remove default timeout.
[sliver-openvswitch.git] / utilities / ovs-vsctl.8.in
index 46bbbe2..ef080bb 100644 (file)
@@ -4,19 +4,28 @@
 .  ns
 .  IP "\\$1"
 ..
+.de ST
+.  PP
+.  RS -0.15in
+.  I "\\$1"
+.  RE
+..
 .TH ovs\-vsctl 8 "November 2009" "Open vSwitch" "Open vSwitch Manual"
+.\" This program's name:
 .ds PN ovs\-vsctl
+.\" SSL peer program's name:
+.ds SN ovsdb\-server
 .
 .SH NAME
 ovs\-vsctl \- utility for querying and configuring \fBovs\-vswitchd\fR
 .
 .SH SYNOPSIS
-\fBovs\-vsctl\fR [\fIoptions\fR] [\fB\-\-\fR] \fIcommand \fR[\fIargs\fR\&...]
-[\fB\-\-\fR \fIcommand \fR[\fIargs\fR\&...]]
+\fBovs\-vsctl\fR [\fIoptions\fR] \fB\-\-\fR [\fIoptions\fR] \fIcommand
+\fR[\fIargs\fR] [\fB\-\-\fR [\fIoptions\fR] \fIcommand \fR[\fIargs\fR]]...
 .
 .SH DESCRIPTION
 The \fBovs\-vsctl\fR program configures \fBovs\-vswitchd\fR(8) by
-providing a high\-level interface to editing its configuration
+providing a high\-level interface to its configuration
 database.  This program is mainly intended for use when
 \fBovs\-vswitchd\fR is running.  If it is used when
 \fBovs\-vswitchd\fR is not running, then \fB\-\-no\-wait\fR should be
@@ -32,7 +41,16 @@ commands.  Then, if it applied any changes, it waits until
 .PP
 \fBovs\-vsctl\fR can perform any number of commands in a single run,
 implemented as a single atomic transaction against the database.
-Commands are separated on the command line by \fB\-\-\fR arguments.
+.PP
+The \fBovs\-vsctl\fR command line begins with global options (see
+\fBOPTIONS\fR below for details).  The global options are followed by
+one or more commands.  Each command should begin with \fB\-\-\fR by
+itself as a command-line argument, to separate it from the global
+options and following commands.  (If the first command does not have
+any options, then the first \fB\-\-\fR may be omitted.)  The command
+itself starts with command-specific options, if any, followed by the
+command name and any arguments.  See \fBEXAMPLES\fR below for syntax
+examples.
 .
 .SS "Linux VLAN Bridging Compatibility"
 The \fBovs\-vsctl\fR program supports the model of a bridge
@@ -64,19 +82,18 @@ the global options by \fB\-\-\fR.
 .IP "\fB\-\-db=\fIserver\fR"
 Sets \fIserver\fR as the database server that \fBovs\-vsctl\fR
 contacts to query or modify configuration.  The default is
-\fBunix:@RUNDIR@/ovsdb\-server\fR.  \fIserver\fR must take one of the
+\fBunix:@RUNDIR@/db.sock\fR.  \fIserver\fR must take one of the
 following forms:
 .RS
-.IP "\fBtcp:\fIip\fB:\fIport\fR"
-Connect to the given TCP \fIport\fR on \fIip\fR.
-.IP "\fBunix:\fIfile\fR"
-Connect to the Unix domain server socket named \fIfile\fR.
+.so ovsdb/remote-active.man
+.so ovsdb/remote-passive.man
 .RE
+.
 .IP "\fB\-\-no\-wait\fR"
 Prevents \fBovs\-vsctl\fR from waiting for \fBovs\-vswitchd\fR to
 reconfigure itself according to the the modified database.  This
 option should be used if \fBovs\-vswitchd\fR is not running;
-otherwise, \fBovs-vsctl\fR will not exit until \fBovs-vswitchd\fR
+otherwise, \fBovs\-vsctl\fR will not exit until \fBovs\-vswitchd\fR
 starts.
 .IP
 This option has no effect if the commands specified do not change the
@@ -96,25 +113,68 @@ lines are printed as \fB\\n\fR, and any instances of \fB\\\fR that
 would otherwise appear in the output are doubled.
 Prints a blank line for each command that has no output.
 .
+.IP "\fB\-\-dry\-run\fR"
+Prevents \fBovs\-vsctl\fR from actually modifying the database.
+.
+.IP "\fB\-t \fIsecs\fR"
+.IQ "\fB\-\-timeout=\fIsecs\fR"
+By default, or with a \fIsecs\fR of \fB0\fR, \fBovs\-vsctl\fR waits
+forever for a response from the database.  This option limits runtime
+to approximately \fIsecs\fR seconds.  If the timeout expires,
+\fBovs\-vsctl\fR will exit with a \fBSIGALRM\fR signal.  (A timeout
+would normally happen only if the database cannot be contacted, or if
+the system is overloaded.)
+.
+.SS "Public Key Infrastructure Options"
+.so lib/ssl.man
+.so lib/ssl-bootstrap.man
+.so lib/ssl-peer-ca-cert.man
 .so lib/vlog.man
 .
 .SH COMMANDS
 The commands implemented by \fBovs\-vsctl\fR are described in the
 sections below.
+.SS "Open vSwitch Commands"
+These commands work with an Open vSwitch as a whole.
+.
+.IP "\fBinit\fR"
+Initializes the Open vSwitch database, if it is empty.  If the
+database has already been initialized, this command has no effect.
+.IP
+Any successful \fBovs\-vsctl\fR command automatically initializes the
+Open vSwitch database if it is empty.  This command is provided to
+initialize the database without executing any other command.
+.
+.IP "\fBemer\-reset\fR"
+Reset the configuration into a clean state.  It deconfigures OpenFlow
+controllers, OVSDB servers, and SSL, and deletes port mirroring,
+NetFlow, and sFlow configuration.  This command also removes all
+\fBother\-config\fR keys from all database records, except that
+\fBother\-config:hwaddr\fR is preserved if it is present in a Bridge
+record.  Other networking configuration is left as-is.
 .
 .SS "Bridge Commands"
 These commands examine and manipulate Open vSwitch bridges.
 .
-.IP "\fBadd\-br \fIbridge\fR"
+.IP "[\fB\-\-may\-exist\fR] \fBadd\-br \fIbridge\fR"
 Creates a new bridge named \fIbridge\fR.  Initially the bridge will
 have no ports (other than \fIbridge\fR itself).
+.IP
+Without \fB\-\-may\-exist\fR, attempting to create a bridge that
+exists is an error.  With \fB\-\-may\-exist\fR, \fIbridge\fR may
+already exist (but it must be a real bridge, not a VLAN bridge).
 .
-.IP "\fBadd\-br \fIbridge parent vlan\fR"
+.IP "[\fB\-\-may\-exist\fR] \fBadd\-br \fIbridge parent vlan\fR"
 Creates a ``fake bridge'' named \fIbridge\fR within the existing Open
 vSwitch bridge \fIparent\fR, which must already exist and must not
 itself be a fake bridge.  The new fake bridge will be on 802.1Q VLAN
 \fIvlan\fR, which must be an integer between 1 and 4095.  Initially
 \fIbridge\fR will have no ports (other than \fIbridge\fR itself).
+.IP
+Without \fB\-\-may\-exist\fR, attempting to create a bridge that
+exists is an error.  With \fB\-\-may\-exist\fR, \fIbridge\fR may
+already exist (but it must have the specified \fIvlan\fR and
+\fIparent\fR).
 .
 .IP "[\fB\-\-if\-exists\fR] \fBdel\-br \fIbridge\fR"
 Deletes \fIbridge\fR and all of its ports.  If \fIbridge\fR is a real
@@ -154,12 +214,22 @@ If \fIvalue\fR is specified, then \fIkey\fR is set to \fIvalue\fR for
 \fIbridge\fR, overwriting any previous value.  If \fIvalue\fR is
 omitted, then \fIkey\fR is removed from \fIbridge\fR's set of external
 IDs (if it was present).
+.IP
+For real bridges, the effect of this command is similar to that of a
+\fBset\fR or \fBremove\fR command in the \fBexternal\-ids\fR column of
+the \fBBridge\fR table.  For fake bridges, it actually modifies keys
+with names prefixed by \fBfake\-bridge\-\fR in the \fBPort\fR table.
 .
 .IP "\fBbr\-get\-external\-id \fIbridge\fR [\fIkey\fR]"
 Queries the external IDs on \fIbridge\fR.  If \fIkey\fR is specified,
 the output is the value for that \fIkey\fR or the empty string if
 \fIkey\fR is unset.  If \fIkey\fR is omitted, the output is
 \fIkey\fB=\fIvalue\fR, one per line, for each key-value pair.
+.IP
+For real bridges, the effect of this command is similar to that of a
+\fBget\fR command in the \fBexternal\-ids\fR column of the
+\fBBridge\fR table.  For fake bridges, it queries keys with names
+prefixed by \fBfake\-bridge\-\fR in the \fBPort\fR table.
 .
 .SS "Port Commands"
 .
@@ -170,14 +240,36 @@ commands treat a bonded port as a single entity.
 Lists all of the ports within \fIbridge\fR on standard output, one per
 line.  The local port \fIbridge\fR is not included in the list.
 .
-.IP "\fBadd\-port \fIbridge port\fR"
+.IP "[\fB\-\-may\-exist\fR] \fBadd\-port \fIbridge port \fR[\fIcolumn\fR[\fB:\fIkey\fR]\fR=\fIvalue\fR]\&...\fR"
 Creates on \fIbridge\fR a new port named \fIport\fR from the network
 device of the same name.
+.IP
+Optional arguments set values of column in the Port record created by
+the command.  For example, \fBtag=9\fR would make the port an access
+port for VLAN 9.  The syntax is the same as that for the \fBset\fR
+command (see \fBDatabase Commands\fR below).
+.IP
+Without \fB\-\-may\-exist\fR, attempting to create a port that exists
+is an error.  With \fB\-\-may\-exist\fR, \fIport\fR may already exist
+(but it must be on \fIbridge\fR and not be a bonded port).
 .
-.IP "\fBadd\-bond \fIbridge port iface\fR\&..."
+.IP "[\fB\-\-fake\-iface\fR] \fBadd\-bond \fIbridge port iface\fR\&... [\fIcolumn\fR[\fB:\fIkey\fR]\fR=\fIvalue\fR]\&...\fR"
 Creates on \fIbridge\fR a new port named \fIport\fR that bonds
 together the network devices given as each \fIiface\fR.  At least two
 interfaces must be named.
+.IP
+Optional arguments set values of column in the Port record created by
+the command.  The syntax is the same as that for the \fBset\fR command
+(see \fBDatabase Commands\fR below).
+.IP
+With \fB\-\-fake\-iface\fR, a fake interface with the name \fIport\fR is
+created.  This should only be used for compatibility with legacy
+software that requires it.
+.IP
+Without \fB\-\-may\-exist\fR, attempting to create a port that exists
+is an error.  With \fB\-\-may\-exist\fR, \fIport\fR may already exist
+(but it must be on \fIbridge\fR and bond together exactly the
+specified interface).
 .
 .IP "[\fB\-\-if\-exists\fR] \fBdel\-port \fR[\fIbridge\fR] \fIport\fR"
 Deletes \fIport\fR.  If \fIbridge\fR is omitted, \fIport\fR is removed
@@ -188,29 +280,21 @@ Without \fB\-\-if\-exists\fR, attempting to delete a port that does
 not exist is an error.  With \fB\-\-if\-exists\fR, attempting to
 delete a port that does not exist has no effect.
 .
+.IP "[\fB\-\-if\-exists\fR] \fB\-\-with\-iface del\-port \fR[\fIbridge\fR] \fIiface\fR"
+Deletes the port named \fIiface\fR or that has an interface named
+\fIiface\fR.  If \fIbridge\fR is omitted, the port is removed from
+whatever bridge contains it; if \fIbridge\fR is specified, it must be
+the real or fake bridge that contains the port.
+.IP
+Without \fB\-\-if\-exists\fR, attempting to delete the port for an
+interface that does not exist is an error.  With \fB\-\-if\-exists\fR,
+attempting to delete the port for an interface that does not exist has
+no effect.
+.
 .IP "\fBport\-to\-br \fIport\fR"
 Prints the name of the bridge that contains \fIport\fR on standard
 output.
 .
-.IP "\fBport\-set\-external\-id \fIport key\fR [\fIvalue\fR]"
-Sets or clears an ``external ID'' value on \fIport\fR.  These value
-are intended to identify entities external to Open vSwitch with which
-\fIport\fR is associated, e.g. the port's identifier in a
-virtualization management platform.  The Open vSwitch database schema
-specifies well-known \fIkey\fR values, but \fIkey\fR and \fIvalue\fR
-are otherwise arbitrary strings.
-.IP
-If \fIvalue\fR is specified, then \fIkey\fR is set to \fIvalue\fR for
-\fIport\fR, overwriting any previous value.  If \fIvalue\fR is
-omitted, then \fIkey\fR is removed from \fIport\fR's set of external
-IDs (if it was present).
-.
-.IP "\fBbr\-get\-external\-id \fIport\fR [\fIkey\fR]"
-Queries the external IDs on \fIport\fR.  If \fIkey\fR is specified,
-the output is the value for that \fIkey\fR or the empty string if
-\fIkey\fR is unset.  If \fIkey\fR is omitted, the output is
-\fIkey\fB=\fIvalue\fR, one per line, for each key-value pair.
-.
 .SS "Interface Commands"
 .
 These commands examine the interfaces attached to an Open vSwitch
@@ -226,35 +310,308 @@ list.
 Prints the name of the bridge that contains \fIiface\fR on standard
 output.
 .
-.IP "\fBiface\-set\-external\-id \fIiface key\fR [\fIvalue\fR]"
-Sets or clears an ``external ID'' value on \fIiface\fR.  These value
-are intended to identify entities external to Open vSwitch with which
-\fIiface\fR is associated, e.g. the interface's identifier in a
-virtualization management platform.  The Open vSwitch database schema
-specifies well-known \fIkey\fR values, but \fIkey\fR and \fIvalue\fR
-are otherwise arbitrary strings.
-.IP
-If \fIvalue\fR is specified, then \fIkey\fR is set to \fIvalue\fR for
-\fIiface\fR, overwriting any previous value.  If \fIvalue\fR is
-omitted, then \fIkey\fR is removed from \fIiface\fR's set of external
-IDs (if it was present).
+.SS "OpenFlow Controller Connectivity"
 .
-.IP "\fBbr\-get\-external\-id \fIiface\fR [\fIkey\fR]"
-Queries the external IDs on \fIiface\fR.  If \fIkey\fR is specified,
-the output is the value for that \fIkey\fR or the empty string if
-\fIkey\fR is unset.  If \fIkey\fR is omitted, the output is
-\fIkey\fB=\fIvalue\fR, one per line, for each key-value pair.
+\fBovs\-vswitchd\fR can perform all configured bridging and switching
+locally, or it can be configured to connect a given bridge to one or
+more external OpenFlow controllers, such as NOX.
 .
+.IP "\fBget\-controller\fR \fIbridge\fR"
+Prints the configured controller target.
+.
+.IP "\fBdel\-controller\fR \fIbridge\fR"
+Deletes the configured controller target.
+.
+.IP "\fBset\-controller\fR \fIbridge\fR \fItarget\fR\&..."
+Sets the configured controller target or targets.  Each \fItarget\fR may
+use any of the following forms:
+.
+.RS
+.so lib/vconn-active.man
+.RE
+.
+.ST "Controller Failure Settings"
+.PP
+When a controller is configured, it is, ordinarily, responsible for
+setting up all flows on the switch.  Thus, if the connection to
+the controller fails, no new network connections can be set up.  If
+the connection to the controller stays down long enough, no packets
+can pass through the switch at all.
+.PP
+If the value is \fBstandalone\fR, or if neither of these settings
+is set, \fBovs\-vswitchd\fR will take over
+responsibility for setting up
+flows when no message has been received from the controller for three
+times the inactivity probe interval (xxx needs to be exposed).  In this mode,
+\fBovs\-vswitchd\fR causes the datapath to act like an ordinary
+MAC-learning switch.  \fBovs\-vswitchd\fR will continue to retry connecting
+to the controller in the background and, when the connection succeeds,
+it discontinues its standalone behavior.
+.PP
+If this option is set to \fBsecure\fR, \fBovs\-vswitchd\fR will not
+set up flows on its own when the controller connection fails.
+.
+.IP "\fBget\-fail\-mode\fR \fIbridge\fR"
+Prints the configured failure mode.
+.
+.IP "\fBdel\-fail\-mode\fR \fIbridge\fR"
+Deletes the configured failure mode.
+.
+.IP "\fBset\-fail\-mode\fR \fIbridge\fR \fBstandalone\fR|\fBsecure\fR"
+Sets the configured failure mode.
+.
+.SS "SSL Configuration"
+When \fBovs\-vswitchd\fR is configured to connect over SSL for management or
+controller connectivity, the following parameters are required:
+.TP
+\fBprivate\-key\fR
+Specifies a PEM file containing the private key used as the virtual
+switch's identity for SSL connections to the controller.
+.TP
+\fBcertificate\fR
+Specifies a PEM file containing a certificate, signed by the
+certificate authority (CA) used by the controller and manager, that
+certifies the virtual switch's private key, identifying a trustworthy
+switch.
+.TP
+\fBca\-cert\fR
+Specifies a PEM file containing the CA certificate used to verify that
+the virtual switch is connected to a trustworthy controller.
+.PP
+These files are read only once, at \fBovs\-vswitchd\fR startup time.  If
+their contents change, \fBovs\-vswitchd\fR must be killed and restarted.
+.PP
+These SSL settings apply to all SSL connections made by the virtual
+switch.
+.
+.IP "\fBget\-ssl\fR"
+Prints the SSL configuration.
+.
+.IP "\fBdel\-ssl\fR"
+Deletes the current SSL configuration.
+.
+.IP "[\fB\-\-bootstrap\fR] \fBset\-ssl\fR \fIprivate-key\fR \fIcertificate\fR \fIca-cert\fR"
+Sets the SSL configuration.  The \fB\-\-bootstrap\fR option is described 
+below.
+.
+.ST "CA Certificate Bootstrap"
+.PP
+Ordinarily, all of the files named in the SSL configuration must exist
+when \fBovs\-vswitchd\fR starts.  However, if the \fB\-\-bootstrap\fR 
+option is given, then \fBovs\-vswitchd\fR will attempt to obtain the
+CA certificate from the controller on its first SSL connection and
+save it to the named PEM file.  If it is successful, it will
+immediately drop the connection and reconnect, and from then on all
+SSL connections must be authenticated by a certificate signed by the
+CA certificate thus obtained.
+.PP
+\fBThis option exposes the SSL connection to a man-in-the-middle
+attack obtaining the initial CA certificate\fR, but it may be useful
+for bootstrapping.
+.PP
+This option is only useful if the controller sends its CA certificate
+as part of the SSL certificate chain.  The SSL protocol does not
+require the controller to send the CA certificate, but
+\fBovs\-controller\fR(8) can be configured to do so with the
+\fB\-\-peer\-ca\-cert\fR option.
+.
+.SS "Database Commands"
+.
+These commands query and modify the contents of \fBovsdb\fR tables.
+They are a slight abstraction of the \fBovsdb\fR interface and as such
+they operate at a lower level than other \fBovs\-vsctl\fR commands.
+.PP
+.ST "Identifying Tables, Records, and Columns"
+.PP
+Each of these commands has a \fItable\fR parameter to identify a table
+within the database.  Many of them also take a \fIrecord\fR parameter
+that identifies a particular record within a table.  The \fIrecord\fR
+parameter may be the UUID for a record, and many tables offer
+additional ways to identify records.  Some commands also take
+\fIcolumn\fR parameters that identify a particular field within the
+records in a table.
+.PP
+The following tables are currently defined:
+.IP "\fBOpen_vSwitch\fR"
+Global configuration for an \fBovs\-vswitchd\fR.  This table contains
+exactly one record, identified by specifying \fB.\fR as the record
+name.
+.IP "\fBBridge\fR"
+Configuration for a bridge within an Open vSwitch.  Records may be
+identified by bridge name.
+.IP "\fBPort\fR"
+A bridge port.  Records may be identified by port name.
+.IP "\fBInterface\fR"
+A network device attached to a port.  Records may be identified by
+name.
+.IP "\fBMirror\fR"
+A port mirroring configuration attached to a bridge.  Records may be
+identified by mirror name.
+.IP "\fBController\fR"
+Configuration for an OpenFlow controller.  A controller attached to a
+particular bridge may be identified by the bridge's name.
+.IP "\fBNetFlow\fR"
+A NetFlow configuration attached to a bridge.  Records may be
+identified by bridge name.
+.IP "\fBSSL\fR"
+The global SSL configuration for \fBovs\-vswitchd\fR.  The record
+attached to the \fBOpen_vSwitch\fR table may be identified by
+specifying \fB.\fR as the record name.
+.IP "\fBsFlow\fR"
+An sFlow configuration attached to a bridge.  Records may be
+identified by bridge name.
+.PP
+Record names must be specified in full and with correct
+capitalization.  Names of tables and columns are not case-sensitive,
+and \fB\-\-\fR and \fB_\fR are treated interchangeably.  Unique
+abbreviations are acceptable, e.g. \fBnet\fR or \fBn\fR is sufficient
+to identify the \fBNetFlow\fR table.
+.
+.ST "Database Values"
+.PP
+Each column in the database accepts a fixed type of data.  The
+currently defined basic types, and their representations, are:
+.IP "integer"
+A decimal integer in the range \-2**63 to 2**63\-1, inclusive.
+.IP "real"
+A floating-point number.
+.IP "Boolean"
+True or false, written \fBtrue\fR or \fBfalse\fR, respectively.
+.IP "string"
+An arbitrary Unicode string, except that null bytes are not allowed.
+Quotes are optional for most strings that begin with an English letter
+or underscore and consist only of letters, underscores, hyphens, and
+periods.  However, \fBtrue\fR and \fBfalse\fR and strings that match
+the syntax of UUIDs (see below) must be enclosed in double quotes to
+distinguish them from other basic types.  When double quotes are used,
+the syntax is that of strings in JSON, e.g. backslashes may be used to
+escape special characters.  The empty string must be represented as a
+pair of double quotes (\fB""\fR).
+.IP "UUID"
+Either a universally unique identifier in the style of RFC 4122,
+e.g. \fBf81d4fae\-7dec\-11d0\-a765\-00a0c91e6bf6\fR, or an \fB@\fIname\fR
+defined by the \fBcreate\fR command within the same \fBovs\-vsctl\fR
+invocation.
+.PP
+Multiple values in a single column may be separated by spaces or a
+single comma.  When multiple values are present, duplicates are not
+allowed, and order is not important.  Conversely, some database
+columns can have an empty set of values, represented as \fB[]\fR, and
+square brackets may optionally enclose other non-empty sets or single
+values as well.
+.PP
+A few database columns are ``maps'' of key-value pairs, where the key
+and the value are each some fixed database type.  These are specified
+in the form \fIkey\fB=\fIvalue\fR, where \fIkey\fR and \fIvalue\fR
+follow the syntax for the column's key type and value type,
+respectively.  When multiple pairs are present (separated by spaces or
+a comma), duplicate keys are not allowed, and again the order is not
+important.  Duplicate values are allowed.  An empty map is represented
+as \fB{}\fR, and curly braces may be optionally enclose non-empty maps
+as well.
+.
+.ST "Database Command Syntax"
+.IP "\fBlist \fItable \fR[\fIrecord\fR]..."
+List the values of all columns of each specified \fIrecord\fR.  If no
+records are specified, lists all the records in \fItable\fR.
+.IP
+The UUIDs shown for rows created in the same \fBovs\-vsctl\fR
+invocation will be wrong.
+.
+.IP "[\fB\-\-if\-exists\fR] \fBget \fItable record column\fR[\fB:\fIkey\fR]..."
+Prints the value of each specified \fIcolumn\fR in the given
+\fIrecord\fR in \fItable\fR.  For map columns, a \fIkey\fR may
+optionally be specified, in which case the value associated with
+\fIkey\fR in the column is printed, instead of the entire map.
+.IP
+For a map column, without \fB\-\-if\-exists\fR it is an error if
+\fIkey\fR does not exist; with it, a blank line is printed.  If
+\fIcolumn\fR is not a map column or if \fIkey\fR is not specified,
+\fB\-\-if\-exists\fR has no effect.
+.
+.IP "\fBset \fItable record column\fR[\fB:\fIkey\fR]\fB=\fIvalue\fR..."
+Sets the value of each specified \fIcolumn\fR in the given
+\fIrecord\fR in \fItable\fR to \fIvalue\fR.  For map columns, a
+\fIkey\fR may optionally be specified, in which case the value
+associated with \fIkey\fR in that column is changed (or added, if none
+exists), instead of the entire map.
+.
+.IP "\fBadd \fItable record column \fR[\fIkey\fB=\fR]\fIvalue\fR..."
+Adds the specified value or key-value pair to \fIcolumn\fR in
+\fIrecord\fR in \fItable\fR.  If \fIcolumn\fR is a map, then \fIkey\fR
+is required, otherwise it is prohibited.  If \fIkey\fR already exists
+in a map column, then the current \fIvalue\fR is not replaced (use the
+\fBset\fR command to replace an existing value).
+.
+.IP "\fBremove \fItable record column \fR\fIvalue\fR..."
+.IQ "\fBremove \fItable record column \fR\fIkey\fR..."
+.IQ "\fBremove \fItable record column \fR\fIkey\fB=\fR\fIvalue\fR..."
+Removes the specified values or key-value pairs from \fIcolumn\fR in
+\fIrecord\fR in \fItable\fR.  The first form applies to columns that
+are not maps: each specified \fIvalue\fR is removed from the column.
+The second and third forms apply to map columns: if only a \fIkey\fR
+is specified, then any key-value pair with the given \fIkey\fR is
+removed, regardless of its value; if a \fIvalue\fR is given then a
+pair is removed only if both key and value match.
+.IP
+It is not an error if the column does not contain the specified key or
+value or pair.
+.
+.IP "\fBclear\fR \fItable record column\fR..."
+Sets each \fIcolumn\fR in \fIrecord\fR in \fItable\fR to the empty set
+or empty map, as appropriate.  This command applies only to columns
+that are allowed to be empty.
+.
+.IP "[\fB\-\-id=@\fIname\fR] \fBcreate\fR \fItable column\fR[\fB:\fIkey\fR]\fB=\fIvalue\fR..."
+Creates a new record in \fItable\fR and sets the initial values of
+each \fIcolumn\fR.  Columns not explicitly set will receive their
+default values.  Outputs the UUID of the new row.
+.IP
+If \fB@\fIname\fR is specified, then the UUID for the new row may be
+referred to by that name elsewhere in the same \fBovs\-vsctl\fR
+invocation in contexts where a UUID is expected.  Such references may
+precede or follow the \fBcreate\fR command.
+.
+.IP "\fR[\fB\-\-if\-exists\fR] \fBdestroy \fItable record\fR..."
+Deletes each specified \fIrecord\fR from \fItable\fR.  Unless
+\fB\-\-if\-exists\fR is specified, each \fIrecord\fRs must exist.
+.
+.IP "\fBwait\-until \fItable record \fR[\fIcolumn\fR[\fB:\fIkey\fR]\fB=\fIvalue\fR]..."
+Waits until \fItable\fR contains a record named \fIrecord\fR whose
+\fIcolumn\fR equals \fIvalue\fR or, if \fIkey\fR is specified, whose
+\fIcolumn\fR contains a \fIkey\fR with the specified \fIvalue\fR.  Any
+of the operators \fB!=\fR, \fB<\fR, \fB>\fR, \fB<=\fR, or \fB>=\fR may
+be substituted for \fB=\fR to test for inequality, less than, greater
+than, less than or equal to, or greater than or equal to,
+respectively.  (Don't forget to escape \fB<\fR or \fB>\fR from
+interpretation by the shell.)
+.IP
+If no \fIcolumn\fR[\fB:\fIkey\fR]\fB=\fIvalue\fR arguments are given,
+this command waits only until \fIrecord\fR exists.  If more than one
+such argument is given, the command waits until all of them are
+satisfied.
+.IP
+Usually \fBwait\-until\fR should be placed at the beginning of a set
+of \fBovs\-vsctl\fR commands.  For example, \fBwait\-until bridge br0
+\-\- get bridge br0 datapath_id\fR waits until a bridge named
+\fBbr0\fR is created, then prints its \fBdatapath_id\fR column,
+whereas \fBget bridge br0 datapath_id \-\- wait\-until bridge br0\fR
+will abort if no bridge named \fBbr0\fR exists when \fBovs\-vsctl\fR
+initially connects to the database.
+.IP
+Consider specifying \fB\-\-timeout=0\fR along with
+\fB\-\-wait\-until\fR, to prevent \fBovs\-vsctl\fR from terminating
+after waiting only at most 5 seconds.
 .SH "EXAMPLES"
 Create a new bridge named br0 and add port eth0 to it:
 .IP
-.B "ovs-vsctl add\-br br0"
+.B "ovs\-vsctl add\-br br0"
 .br
-.B "ovs-vsctl add\-port br0 eth0"
+.B "ovs\-vsctl add\-port br0 eth0"
 .PP
 Alternatively, perform both operations in a single atomic transaction:
 .IP 
-.B "ovs-vsctl add\-br br0 \-\- add\-port br0 eth0"
+.B "ovs\-vsctl add\-br br0 \-\- add\-port br0 eth0"
 .PP
 Delete bridge \fBbr0\fR, reporting an error if it does not exist:
 .IP
@@ -264,6 +621,12 @@ Delete bridge \fBbr0\fR if it exists (the \fB\-\-\fR is required to
 separate \fBdel\-br\fR's options from the global options):
 .IP
 .B "ovs\-vsctl \-\- \-\-if\-exists del\-br br0"
+.PP
+Set the \fBqos\fR column of the \fBPort\fR record for \fBeth0\fR to
+point to a new \fBQoS\fR record, which in turn points with its queue 0
+to a new \fBQueue\fR record:
+.IP
+.B "ovs\-vsctl \-\- set port eth0 qos=@newqos \-\- \-\-id=@newqos create qos type=linux\-htb other\-config:max\-rate=1000000 queues:0=@newqueue \-\- \-\-id=@newqueue create queue other\-config:min\-rate=1000000 other\-config:max\-rate=1000000"
 .
 .SH "EXIT STATUS"
 .IP "0"
@@ -277,3 +640,4 @@ bridge that does not exist.
 .
 .BR ovsdb\-server (1),
 .BR ovs\-vswitchd (8).
+\