Release Open vSwitch 1.0.2
[sliver-openvswitch.git] / utilities / ovs-vsctl.8.in
index 3137a84..ef080bb 100644 (file)
 .  RE
 ..
 .TH ovs\-vsctl 8 "November 2009" "Open vSwitch" "Open vSwitch Manual"
+.\" This program's name:
 .ds PN ovs\-vsctl
+.\" SSL peer program's name:
+.ds SN ovsdb\-server
 .
 .SH NAME
 ovs\-vsctl \- utility for querying and configuring \fBovs\-vswitchd\fR
@@ -115,14 +118,17 @@ Prevents \fBovs\-vsctl\fR from actually modifying the database.
 .
 .IP "\fB\-t \fIsecs\fR"
 .IQ "\fB\-\-timeout=\fIsecs\fR"
-Limits runtime to approximately \fIsecs\fR seconds.  A value of 
-zero will cause \fBovs\-vsctl\fR to wait forever.  If the timeout expires, 
-\fBovs\-vsctl\fR will exit with a \fBSIGALRM\fR signal.  If this option is
-not used, \fBovs\-vsctl\fR uses a timeout of five seconds.
-(A timeout would normally happen only if the database cannot be contacted.)
+By default, or with a \fIsecs\fR of \fB0\fR, \fBovs\-vsctl\fR waits
+forever for a response from the database.  This option limits runtime
+to approximately \fIsecs\fR seconds.  If the timeout expires,
+\fBovs\-vsctl\fR will exit with a \fBSIGALRM\fR signal.  (A timeout
+would normally happen only if the database cannot be contacted, or if
+the system is overloaded.)
 .
 .SS "Public Key Infrastructure Options"
 .so lib/ssl.man
+.so lib/ssl-bootstrap.man
+.so lib/ssl-peer-ca-cert.man
 .so lib/vlog.man
 .
 .SH COMMANDS
@@ -310,22 +316,15 @@ output.
 locally, or it can be configured to connect a given bridge to one or
 more external OpenFlow controllers, such as NOX.
 .
-For each of these commands, a \fIbridge\fR of \fBdefault\fR applies
-the configuration as the default for any bridge that has not been
-explicitly configured.  Otherwise, \fIbridge\fR must name a bridge,
-and the settings apply only to that bridge.  (Omitting \fIbridge\fR
-entirely usually has the same effect as specifying \fBdefault\fR.)
-.
-.IP "\fBget\-controller\fR [\fIbridge\fR]"
+.IP "\fBget\-controller\fR \fIbridge\fR"
 Prints the configured controller target.
 .
-.IP "\fBdel\-controller\fR [\fIbridge\fR]"
+.IP "\fBdel\-controller\fR \fIbridge\fR"
 Deletes the configured controller target.
 .
-.IP "\fBset\-controller\fR [\fIbridge\fR] \fItarget\fR\&..."
-Sets the configured controller target or targets.  If more than one
-\fItarget\fR is specified, then \fIbridge\fR may not be omitted.  Each
-\fItarget\fR may use any of the following forms:
+.IP "\fBset\-controller\fR \fIbridge\fR \fItarget\fR\&..."
+Sets the configured controller target or targets.  Each \fItarget\fR may
+use any of the following forms:
 .
 .RS
 .so lib/vconn-active.man
@@ -352,13 +351,13 @@ it discontinues its standalone behavior.
 If this option is set to \fBsecure\fR, \fBovs\-vswitchd\fR will not
 set up flows on its own when the controller connection fails.
 .
-.IP "\fBget\-fail\-mode\fR [\fIbridge\fR]"
+.IP "\fBget\-fail\-mode\fR \fIbridge\fR"
 Prints the configured failure mode.
 .
-.IP "\fBdel\-fail\-mode\fR [\fIbridge\fR]"
+.IP "\fBdel\-fail\-mode\fR \fIbridge\fR"
 Deletes the configured failure mode.
 .
-.IP "\fBset\-fail\-mode\fR [\fIbridge\fR] \fBstandalone\fR|\fBsecure\fR"
+.IP "\fBset\-fail\-mode\fR \fIbridge\fR \fBstandalone\fR|\fBsecure\fR"
 Sets the configured failure mode.
 .
 .SS "SSL Configuration"
@@ -413,7 +412,7 @@ for bootstrapping.
 This option is only useful if the controller sends its CA certificate
 as part of the SSL certificate chain.  The SSL protocol does not
 require the controller to send the CA certificate, but
-\fBcontroller\fR(8) can be configured to do so with the
+\fBovs\-controller\fR(8) can be configured to do so with the
 \fB\-\-peer\-ca\-cert\fR option.
 .
 .SS "Database Commands"
@@ -450,9 +449,7 @@ A port mirroring configuration attached to a bridge.  Records may be
 identified by mirror name.
 .IP "\fBController\fR"
 Configuration for an OpenFlow controller.  A controller attached to a
-particular bridge may be identified by the bridge's name.  The default
-controller controller for an Open vSwitch may be identified by
-specifying \fB.\fR as the record name.
+particular bridge may be identified by the bridge's name.
 .IP "\fBNetFlow\fR"
 A NetFlow configuration attached to a bridge.  Records may be
 identified by bridge name.