ofproto: Use 64-bit datapath id and management id (OpenFlow 0.9)
[sliver-openvswitch.git] / vswitchd / ovs-vswitchd.conf.5.in
index 4d4bb48..fb44c78 100644 (file)
@@ -346,12 +346,15 @@ on port 1, disrupting connectivity.  If mirroring to a VLAN is desired
 in this scenario, then the physical switch must be replaced by one
 that learns Ethernet addresses on a per-VLAN basis.  In addition,
 learning should be disabled on the VLAN containing mirrored traffic.
-If this is not done then the intermediate switch will learn the MAC
+If this is not done then intermediate switches will learn the MAC
 address of each end host from the mirrored traffic.  If packets being
 sent to that end host are also mirrored, then they will be dropped
 since the switch will attempt to send them out the input port.
 Disabling learning for the VLAN will cause the switch to correctly
-send the packet out all ports configured for that VLAN.
+send the packet out all ports configured for that VLAN.  If Open
+vSwitch is being used as an intermediate switch learning can be disabled
+by setting the key \fBvlan.\fIbrname\fB.disable-learning=\fIvid\fR
+to the mirrored VLAN.
 .ST "Example"
 The following \fBovs\-vswitchd\fR configuration copies all frames received
 on \fBeth1\fR or \fBeth2\fR to \fBeth3\fR.
@@ -411,18 +414,24 @@ port.eth1.ingress.policing-burst=20
 
 .fi
 .SS "NetFlow v5 Flow Logging"
-NetFlow is a protocol that exports a number of details about terminating 
-IP flows, such as the principals involved and duration.  A bridge may be 
-configured to send NetFlow v5 records to NetFlow collectors when flows 
-end.  To enable, define the key \fBnetflow.\fIbridge\fB.host\fR for each 
-collector in the form \fIip\fB:\fIport\fR.  Records from \fIbridge\fR 
+NetFlow is a protocol that exports a number of details about terminating
+IP flows, such as the principals involved and duration.  A bridge may be
+configured to send NetFlow v5 records to NetFlow collectors when flows
+end.  To enable, define the key \fBnetflow.\fIbridge\fB.host\fR for each
+collector in the form \fIip\fB:\fIport\fR.  Records from \fIbridge\fR
 will be sent to each \fIip\fR on UDP \fIport\fR.  The \fIip\fR must
 be specified numerically, not as a DNS name.
 
-The NetFlow messages will use the datapath index for the engine type and id.  
-This can be overridden with the \fBnetflow.\fIbridge\fB.engine-type\fR and 
+In addition to terminating flows, NetFlow can also send records at a set
+interval for flows that are still active.  This interval can be configured
+by defining the key \fBnetflow.\fIbridge\fB\.active-timeout\fR.  The value
+is in seconds.  An active timeout of 0 will disable this functionality.  By
+default there is timeout value of 600 seconds.
+
+The NetFlow messages will use the datapath index for the engine type and id.
+This can be overridden with the \fBnetflow.\fIbridge\fB.engine-type\fR and
 \fBnetflow.\fIbridge\fB.engine-id\fR, respectively.  Each takes a value
-between 0 and 255, inclusive. 
+between 0 and 255, inclusive.
 
 Many NetFlow collectors do not expect multiple switches to be
 sending messages from the same host, and they do not store the engine
@@ -430,8 +439,15 @@ information which could be used to disambiguate the traffic.  To prevent
 flows from multiple switches appearing as if they came on the interface,
 add \fBnetflow.\fIbridge\fB.add-id-to-iface=true\fR to the configuration
 file.  This will place the least significant 7 bits of the engine id
-into the most significant bits of the ingress and egress interface fields 
-of flow records.  By default, this behavior is disabled.
+into the most significant bits of the ingress and egress interface fields
+of flow records.  When this option is enabled, a maximum of 508 ports are
+supported.  By default, this behavior is disabled.
+
+The egress interface field normally contains the OpenFlow port number,
+however, certain port values have special meaning: 0xFFFF indicates
+flooding, 0xFFFE is multiple controller-specified output interfaces, and
+0xFFFD means that packets from the flow were dropped.  If add-id-to-iface
+is enabled then these values become 0x1FF, 0x1FE, and 0x1FD respectively.
 
 The following syntax sends NetFlow records for \fBmybr\fR to the NetFlow
 collector \fBnflow.example.com\fR on UDP port \fB9995\fR:
@@ -472,7 +488,7 @@ the connection has been broken and attempts to reconnect.  The default
 and minimum values are both 5 seconds.
 
 A management id may be specified with the \fBmgmt.id\fR key.  It takes
-an id in the form of exactly 12 hexadecimal digits.  If one is not
+an id in the form of exactly 16 hexadecimal digits.  If one is not
 specified, a random id is generated each time \fBovs\-vswitchd\fR is started.
 .fi
 .RE
@@ -545,10 +561,11 @@ The Unix domain server socket named \fIfile\fR.
 .PP
 The datapath ID used by the bridge to identify itself to the remote
 controller may be specified as \fBbridge.\fIname\fB.datapath-id\fR,
-in the form of exactly 12 hexadecimal digits.  If the datapath ID
-is not specified, then it defaults to the bridge's MAC address (see
-\fBBridge Configuration\fR, above, for information on how the bridge's
-MAC address is chosen).
+in the form of exactly 16 hexadecimal digits.  If the datapath ID
+is not specified, then it defaults to the bridge's MAC address in
+the lower 48 bits (see \fBBridge Configuration\fR, above, for information 
+on how the bridge's MAC address is chosen) and zeros in the upper 16
+bits.
 .ST "Local Port Network Configuration"
 When an external controller is configured, but controller discovery is
 not in use, the following additional settings are honored: