vswitch.xml: Describe current default fail_mode.
[sliver-openvswitch.git] / vswitchd / vswitch.xml
index 13dd314..94760cc 100644 (file)
           any defined controllers forever.</dd>
         </dl>
         </p>
-        <p>If this value is unset, the default is implementation-specific.</p>
+        <p>
+          The default is <code>standalone</code> if the value is unset, but
+          future versions of Open vSwitch may change the default.
+        </p>
+        <p>
+          The <code>standalone</code> mode can create forwarding loops on a
+          bridge that has more than one uplink port unless STP is enabled.  To
+          avoid loops on such a bridge, configure <code>secure</code> mode or
+          enable STP (see <ref column="stp_enable"/>).
+        </p>
         <p>When more than one controller is configured,
         <ref column="fail_mode"/> is considered only when none of the
         configured controllers can be contacted.</p>
 
       <column name="other_config" key="cfm_interval"
               type='{"type": "integer"}'>
-        The interval, in milliseconds, between transmissions of CFM heartbeats.
-        Three missed heartbeat receptions indicate a connectivity fault.
-        Defaults to 1000.
+        <p>
+          The interval, in milliseconds, between transmissions of CFM
+          heartbeats.  Three missed heartbeat receptions indicate a
+          connectivity fault.
+        </p>
+
+        <p>
+          In standard operation only intervals of 3, 10, 100, 1,000, 10,000,
+          60,000, or 600,000 ms are supported.  Other values will be rounded
+          down to the nearest value on the list.  Extended mode (see <ref
+          column="other_config" key="cfm_extended"/>) supports any interval up
+          to 65,535 ms.  In either mode, the default is 1000 ms.
+        </p>
+
+        <p>We do not recommend using intervals less than 100 ms.</p>
       </column>
 
       <column name="other_config" key="cfm_extended"
         commonly be the same as <ref column="external_ids" key="xs-vif-uuid"/>.
       </column>
 
+      <column name="external_ids" key="iface-status"
+              type='{"type": "string",
+                    "enum": ["set", ["active", "inactive"]]}'>
+        <p>
+          Hypervisors may sometimes have more than one interface associated
+          with a given <ref column="external_ids" key="iface-id"/>, only one of
+          which is actually in use at a given time.  For example, in some
+          circumstances XenServer has both a ``tap'' and a ``vif'' interface
+          for a single <ref column="external_ids" key="iface-id"/>, but only
+          uses one of them at a time.  A hypervisor that behaves this way must
+          mark the currently in use interface <code>active</code> and the
+          others <code>inactive</code>.  A hypervisor that never has more than
+          one interface for a given <ref column="external_ids" key="iface-id"/>
+          may mark that interface <code>active</code> or omit <ref
+          column="external_ids" key="iface-status"/> entirely.
+        </p>
+
+        <p>
+          During VM migration, a given <ref column="external_ids"
+          key="iface-id"/> might transiently be marked <code>active</code> on
+          two different hypervisors.  That is, <code>active</code> means that
+          this <ref column="external_ids" key="iface-id"/> is the active
+          instance within a single hypervisor, not in a broader scope.
+        </p>
+      </column>
+
       <column name="external_ids" key="xs-vif-uuid">
         The virtual interface associated with this interface.
       </column>