</dl>
</p>
</column>
+
+ <column name="other_config" key="n-handler-threads"
+ type='{"type": "integer", "minInteger": 1}'>
+ <p>
+ Specifies the number of threads for software datapaths to use for
+ handling new flows. The default is one less than the number of
+ online CPU cores (but at least 1).
+ </p>
+ <p>
+ This configuration is per datapath. If you have more than one
+ software datapath (e.g. some <code>system</code> bridges and some
+ <code>netdev</code> bridges), then the total number of threads is
+ <code>n-handler-threads</code> times the number of software
+ datapaths.
+ </p>
+ </column>
</group>
<group title="Status">
on a host.
</column>
+ <column name="ifindex">
+ A positive interface index as defined for SNMP MIB-II in RFCs 1213 and
+ 2863, if the interface has one, otherwise 0. The ifindex is useful for
+ seamless integration with protocols such as SNMP and sFlow.
+ </column>
+
<column name="mac_in_use">
The MAC address in use by this interface.
</column>
times the expected reception rate, will signal a connectivity
fault. In the case of a unidirectional connectivity issue, the
system not receiving BFD control messages will signal the problem
- to its peer in the messages is transmists.
+ to its peer in the messages it transmits.
</p>
<p>
specified. Defaults to <code>100</code>.
</column>
+ <column name="bfd" key="decay_min_rx" type='{"type": "integer"}'>
+ <code>decay_min_rx</code> is used to set the <code>min_rx</code>,
+ when there is no obvious incoming data traffic at the interface.
+ It cannot be set less than the <code>min_rx</code>. The decay feature
+ is disabled by setting the <code>decay_min_rx</code> to 0. And the
+ feature is reset everytime itself or <code>min_rx</code> is
+ reconfigured.
+ </column>
+
+ <column name="bfd" key="forwarding_if_rx" type='{"type": "boolean"}'>
+ When <code>forwarding_if_rx</code> is true the interface will be
+ considered capable of packet I/O as long as there is packet
+ received at interface. This is important in that when link becomes
+ temporarily conjested, consecutive BFD control packets can be lost.
+ And the <code>forwarding_if_rx</code> can prevent link failover by
+ detecting non-control packets received at interface.
+ </column>
+
<column name="bfd" key="cpath_down" type='{"type": "boolean"}'>
Concatenated path down may be used when the local system should not
have traffic forwarded to it for some reason other than a connectivty
<code>false</code>.
</column>
+ <column name="bfd" key="check_tnl_key" type='{"type": "boolean"}'>
+ When set to true, Check Tunnel Key will make BFD only accept control
+ messages with an <code>in_key</code> of zero. Defaults to
+ <code>false</code>.
+ </column>
+
+ <column name="bfd" key="bfd_dst_mac">
+ An Ethernet address in the form
+ <var>xx</var>:<var>xx</var>:<var>xx</var>:<var>xx</var>:<var>xx</var>:<var>xx</var>
+ to set the destination mac address of the bfd packet. If this
+ field is set, it is assumed that all the bfd packets destined to this
+ interface also has the same destination mac address. If not set, a
+ default value of <code>00:23:20:00:00:01</code> is used.
+ </column>
+
<column name="bfd_status" key="state"
type='{"type": "string",
"enum": ["set", ["admin_down", "down", "init", "up"]]}'>
referenced from a <ref table="Flow_Sample_Collector_Set"/>.
</column>
+ <column name="cache_active_timeout">
+ The maximum period in seconds for which an IPFIX flow record is
+ cached and aggregated before being sent. If not specified,
+ defaults to 0. If 0, caching is disabled.
+ </column>
+
+ <column name="cache_max_flows">
+ The maximum number of IPFIX flow records that can be cached at a
+ time. If not specified, defaults to 0. If 0, caching is
+ disabled.
+ </column>
+
<group title="Common Columns">
The overall purpose of these columns is described under <code>Common
Columns</code> at the beginning of this document.