VServer 1.9.2 (patch-2.6.8.1-vs1.9.2.diff)
[linux-2.6.git] / drivers / mtd / maps / Kconfig
index 03d39d7..cdc5bbd 100644 (file)
@@ -1,5 +1,5 @@
 # drivers/mtd/maps/Kconfig
-# $Id: Kconfig,v 1.12 2003/06/23 07:38:11 dwmw2 Exp $
+# $Id: Kconfig,v 1.30 2004/07/21 00:16:14 jwboyer Exp $
 
 menu "Mapping drivers for chip access"
        depends on MTD!=n
@@ -19,7 +19,8 @@ config MTD_PHYSMAP
          command set driver code to communicate with flash chips which
          are mapped physically into the CPU's memory. You will need to
          configure the physical address and size of the flash chips on
-         your particular board as well as the bus width.
+         your particular board as well as the bus width, either statically
+         with config options or at run-time.
 
 config MTD_PHYSMAP_START
        hex "Physical start address of flash mapping"
@@ -30,6 +31,8 @@ config MTD_PHYSMAP_START
          are mapped on your particular target board. Refer to the
          memory map which should hopefully be in the documentation for
          your board.
+         Ignore this option if you use run-time physmap configuration
+         (i.e., run-time calling physmap_configure()).
 
 config MTD_PHYSMAP_LEN
        hex "Physical length of flash mapping"
@@ -42,9 +45,11 @@ config MTD_PHYSMAP_LEN
          than the total amount of flash present. Refer to the memory
          map which should hopefully be in the documentation for your
          board.
+         Ignore this option if you use run-time physmap configuration
+         (i.e., run-time calling physmap_configure()).
 
-config MTD_PHYSMAP_BUSWIDTH
-       int "Bus width in octets"
+config MTD_PHYSMAP_BANKWIDTH
+       int "Bank width in octets"
        depends on MTD_PHYSMAP
        default "2"
        help
@@ -52,6 +57,8 @@ config MTD_PHYSMAP_BUSWIDTH
          in octets. For example, if you have a data bus width of 32
          bits, you would set the bus width octect value to 4. This is
          used internally by the CFI drivers.
+         Ignore this option if you use run-time physmap configuration
+         (i.e., run-time calling physmap_configure()).
 
 config MTD_SUN_UFLASH
        tristate "Sun Microsystems userflash support"
@@ -151,11 +158,11 @@ config MTD_AMD76XROM
 
          BE VERY CAREFUL.
 
-config MTD_ICH2ROM
-       tristate "BIOS flash chip on Intel Hub Controller 2"
+config MTD_ICHXROM
+       tristate "BIOS flash chip on Intel Controller Hub 2/3/4/5"
        depends on X86 && MTD_JEDECPROBE && MTD_COMPLEX_MAPPINGS
        help
-         Support for treating the BIOS flash chip on ICH2 motherboards
+         Support for treating the BIOS flash chip on ICHX motherboards
          as an MTD device - with this you can reprogram your BIOS.
 
          BE VERY CAREFUL.
@@ -177,7 +184,7 @@ config MTD_TSUNAMI
 
 config MTD_LASAT
        tristate "Flash chips on LASAT board"
-       depends on LASAT && MTD_CFI
+       depends on LASAT
        help
          Support for the flash chips on the Lasat 100 and 200 boards.
 
@@ -210,6 +217,52 @@ config MTD_PB1XXX_USER
          You can say 'Y' to both this and 'MTD_PB1XXX_BOOT' above, to use
          both banks.
 
+config MTD_PB1550
+       tristate "Flash devices on Alchemy PB1550 board"
+       depends on MIPS && MIPS_PB1550
+       help
+         Flash memory access on Alchemy Pb1550 board
+
+config MTD_PB1550_BOOT
+       bool "PB1550 boot flash device"
+       depends on MTD_PB1550
+       help
+         Use the first of the two 64MiB flash banks on Pb1550 board.
+         You can say 'Y' to both this and 'MTD_PB1550_USER' below, to use
+         both banks.
+
+config MTD_PB1550_USER
+       bool "PB1550 user flash device"
+       depends on MTD_PB1550
+       default y if MTD_PB1550_BOOT = n
+       help
+         Use the second of the two 64MiB flash banks on Pb1550 board.
+         You can say 'Y' to both this and 'MTD_PB1550_BOOT' above, to use
+         both banks.
+
+config MTD_DB1550
+       tristate "Flash devices on Alchemy DB1550 board"
+       depends on MIPS && MIPS_DB1550
+       help
+         Flash memory access on Alchemy Db1550 board
+
+config MTD_DB1550_BOOT
+       bool "DB1550 boot flash device"
+       depends on MTD_DB1550
+       help
+         Use the first of the two 64MiB flash banks on Db1550 board.
+         You can say 'Y' to both this and 'MTD_DB1550_USER' below, to use
+         both banks.
+
+config MTD_DB1550_USER
+       bool "DB1550 user flash device"
+       depends on MTD_DB1550
+       default y if MTD_DB1550_BOOT = n
+       help
+         Use the second of the two 64MiB flash banks on Db1550 board.
+         You can say 'Y' to both this and 'MTD_DB1550_BOOT' above, to use
+         both banks.
+
 config MTD_DILNETPC
        tristate "CFI Flash device mapped on DIL/Net PC"
        depends on X86 && MTD_CONCAT && MTD_PARTITIONS && MTD_CFI_INTELEXT
@@ -235,6 +288,13 @@ config MTD_L440GX
 
          BE VERY CAREFUL.
 
+config MTD_SBC8240
+       tristate "Flash device on SBC8240"
+       depends on PPC32 && MTD_JEDECPROBE && 6xx && 8260
+       help
+          Flash access on the SBC8240 board from Wind River.  See
+          <http://www.windriver.com/products/sbc8240/>
+
 config MTD_TQM8XXL
        tristate "CFI Flash device mapped on TQM8XXL"
        depends on MTD_CFI && PPC32 && 8xx && TQM8xxL
@@ -265,7 +325,7 @@ config MTD_MBX860
 
 config MTD_DBOX2
        tristate "CFI Flash device mapped on D-Box2"
-       depends on PPC32 && 8xx && MTD_CFI_INTELSTD && MTD_CFI_INTELEXT && MTD_CFI_AMDSTD
+       depends on PPC32 && 8xx && DBOX2 && MTD_CFI_INTELSTD && MTD_CFI_INTELEXT && MTD_CFI_AMDSTD
        help
          This enables access routines for the flash chips on the Nokia/Sagem
          D-Box 2 board. If you have one of these boards and would like to use
@@ -457,6 +517,13 @@ config MTD_CEIVA
          PhotoMax Digital Picture Frame.
          If you have such a device, say 'Y'.
 
+config MTD_NOR_TOTO
+       tristate "NOR Flash device on TOTO board"
+       depends on ARM && ARCH_OMAP && OMAP_TOTO
+       help
+         This enables access to the NOR flash on the Texas Instruments
+         TOTO board.
+
 config MTD_H720X
        tristate "Hynix evaluation board mappings"
        depends on ARM && MTD_CFI && ( ARCH_H7201 || ARCH_H7202 )
@@ -464,6 +531,13 @@ config MTD_H720X
          This enables access to the flash chips on the Hynix evaluation boards.
          If you have such a board, say 'Y'.
 
+config MTD_MPC1211
+       tristate "CFI Flash device mapped on Interface MPC-1211"
+       depends on SUPERH && SH_MPC1211 && MTD_CFI
+       help
+         This enables access to the flash chips on the Interface MPC-1211(CTP/PCI/MPC-SH02).
+         If you have such a board, say 'Y'.
+
 # This needs CFI or JEDEC, depending on the cards found.
 config MTD_PCI
        tristate "PCI MTD driver"
@@ -491,11 +565,26 @@ config MTD_UCLINUX
 
 config MTD_WRSBC8260
        tristate "Map driver for WindRiver PowerQUICC II MPC82xx board"
-       depends on MTD_PARTITIONS && SBC82xx
+       depends on (SBC82xx || SBC8560)
+       select MTD_PARTITIONS
+       select MTD_MAP_BANK_WIDTH_4
+       select MTD_MAP_BANK_WIDTH_1
+       select MTD_CFI_I1
+       select MTD_CFI_I4
        help
          Map driver for WindRiver PowerQUICC II MPC82xx board. Drives
          all three flash regions on CS0, CS1 and CS6 if they are configured
          correctly by the boot loader.
 
+config MTD_DMV182
+        tristate "Map driver for Dy-4 SVME/DMV-182 board."
+        depends on DMV182
+        select MTD_PARTITIONS
+       select MTD_MAP_BANK_WIDTH_32
+       select MTD_CFI_I8
+       select MTD_CFI_AMDSTD
+        help
+          Map driver for Dy-4 SVME/DMV-182 board.
+
 endmenu