add steps to build and install Monitor docs into plc
authorStephen Soltesz <soltesz@cs.princeton.edu>
Mon, 4 May 2009 21:33:10 +0000 (21:33 +0000)
committerStephen Soltesz <soltesz@cs.princeton.edu>
Mon, 4 May 2009 21:33:10 +0000 (21:33 +0000)
add default PCU types with names that match monitor-pcucontrol models.

db-config
myplc-docs.spec

index 27fcee7..4a1a22d 100755 (executable)
--- a/db-config
+++ b/db-config
@@ -928,124 +928,69 @@ message, please reply so that we may investigate the problem.
     #################### PCUs
     
     ### Setup Initial PCU information
-    pcu_types = [{'model': 'AP79xx',
-          'name': 'APC AP79xx',
-          'pcu_protocol_types': [{ 'port': 80,
-                                  'protocol': 'APC79xxHttp',
-                                  'supported': False},
-                                 { 'port': 23,
-                                  'protocol': 'APC79xx',
-                                  'supported': True},
-                                 { 'port': 22,
-                                  'protocol': 'APC79xx',
-                                  'supported': True}],
-          },
-         {'model': 'Masterswitch',
-          'name': 'APC Masterswitch',
-          'pcu_protocol_types': [{ 'port': 80,
-                                  'protocol': 'APCMasterHttp',
-                                  'supported': False},
-                                 { 'port': 23,
-                                  'protocol': 'APCMaster',
-                                  'supported': True},
-                                 { 'port': 22,
-                                  'protocol': 'APCMaster',
-                                  'supported': True}],
-          },
-         {'model': 'DS4-RPC',
-          'name': 'BayTech DS4-RPC',
-          'pcu_protocol_types': [{ 'port': 80,
-                                  'protocol': 'BayTechHttp',
-                                  'supported': False},
-                                 { 'port': 23,
-                                  'protocol': 'BayTech',
-                                  'supported': True},
-                                 { 'port': 22,
-                                  'protocol': 'BayTech',
-                                  'supported': True}],
-          },
-         {'model': 'IP-41x_IP-81x',
-          'name': 'Dataprobe IP-41x & IP-81x',
-          'pcu_protocol_types': [ { 'port': 23,
-                                  'protocol': 'IPALTelnet',
-                                  'supported': True},
-                                  { 'port': 80,
-                                  'protocol': 'IPALHttp',
-                                  'supported': False}],
-          },
-         {'model': 'DRAC3',
-          'name': 'Dell RAC Version 3',
-          'pcu_protocol_types': [],
-          },
-         {'model': 'DRAC4',
-          'name': 'Dell RAC Version 4',
-          'pcu_protocol_types': [{ 'port': 443,
-                                  'protocol': 'DRACRacAdm',
-                                  'supported': True},
-                                 { 'port': 80,
-                                  'protocol': 'DRACRacAdm',
-                                  'supported': False},
-                                 { 'port': 22,
-                                  'protocol': 'DRAC',
-                                  'supported': True}],
-          },
-         {'model': 'ePowerSwitch',
-          'name': 'ePowerSwitch 1/4/8x',
-          'pcu_protocol_types': [{ 'port': 80,
-                                  'protocol': 'ePowerSwitch',
-                                  'supported': True}],
-          },
-         {'model': 'ilo2',
-          'name': 'HP iLO2 (Integrated Lights-Out)',
-          'pcu_protocol_types': [{ 'port': 443,
-                                  'protocol': 'HPiLOHttps',
-                                  'supported': True},
-                                 { 'port': 22,
-                                  'protocol': 'HPiLO',
-                                  'supported': True}],
-          },
-         {'model': 'ilo1',
-          'name': 'HP iLO version 1',
-          'pcu_protocol_types': [],
-          },
-         {'model': 'PM211-MIP',
-          'name': 'Infratec PM221-MIP',
-          'pcu_protocol_types': [],
-          },
-         {'model': 'AMT2.5',
-          'name': 'Intel AMT v2.5 (Active Management Technology)',
-          'pcu_protocol_types': [],
-          },
-         {'model': 'AMT3.0',
-          'name': 'Intel AMT v3.0 (Active Management Technology)',
-          'pcu_protocol_types': [],
-          },
-         {'model': 'WTI_IPS-4',
-          'name': 'Western Telematic (WTI IPS-4)',
-          'pcu_protocol_types': [],
-          },
-         {'model': 'unknown',
-          'name': 'Unknown Vendor or Model',
-          'pcu_protocol_types': [{ 'port': 443,
-                                  'protocol': 'UnknownPCU',
-                                  'supported': False},
-                                 { 'port': 80,
-                                  'protocol': 'UnknownPCU',
-                                  'supported': False},
-                                 { 'port': 23,
-                                  'protocol': 'UnknownPCU',
-                                  'supported': False},
-                                 { 'port': 22,
-                                  'protocol': 'UnknownPCU',
-                                  'supported': False}],
-          }]
+       pcu_types = [
+                        {'model': 'APCControl12p3',
+                         'name': 'APC AP79xx or Masterswitch (sequence 1-2-port-3)', },
+                        {'model': 'APCControl1p4',
+                         'name': 'APC AP79xx or Masterswitch (sequence 1-port-4)', },
+                        {'model': 'APCControl121p3',
+                         'name': 'APC AP79xx or Masterswitch (sequence 1-2-1-port-3)', },
+                        {'model': 'APCControl121p1',
+                         'name': 'APC AP79xx or Masterswitch (sequence 1-2-1-port-1)', },
+                        {'model': 'APCControl13p13',
+                         'name': 'APC AP79xx or Masterswitch (sequence 1-3-port-1-3)', },
+
+                        {'model': 'BayTechRPC3NC', 
+                         'name': 'BayTech with prompt RPC3-NC>', },
+                        {'model': 'BayTechRPC16', 
+                         'name': 'BayTech with prompt RPC-16>', },
+                        {'model': 'BayTech',
+                         'name': 'BayTech with prompt DS-RPC>', },
+                        {'model': 'BayTechCtrlC', 
+                         'name': 'BayTech Ctrl-C, 5, then with prompt DS-RPC>', },
+                        {'model': 'BayTechCtrlCUnibe', 
+                         'name': 'BayTech Ctrl-C, 3, then with prompt DS-RPC>', },
+
+                        {'model': 'BlackBoxPSMaverick',
+                         'name': 'BlackBoxPSMaverick Web based controller'},
+
+                        {'model': 'IPAL', 
+                         'name': 'IPAL - Dataprobe IP-41x & IP-81x', },
+                        {'model': 'DRAC',
+                         'name': 'DRAC - Dell RAC Version 3 or 4', },
+                        {'model': 'ePowerSwitchNew',
+                         'name': 'ePowerSwitch Newer Models 1/4/8x', },
+                        {'model': 'ePowerSwitchOld',
+                         'name': 'ePowerSwitch Older Models 1/4/8x', },
+
+                        {'model': 'HPiLO',
+                         'name': 'HP iLO v1 or v2 (Integrated Lights-Out)', },
+
+                        {'model': 'IntelAMT',
+                         'name': 'Intel AMT v2.5 or v3.0 (Active Management Technology)', },
+
+                        {'model': 'IPMI',
+                         'name': 'OpenIPMI - Intelligent Platform Management Interface', },
+
+                        {'model': 'PM211MIP',
+                         'name': 'Infratec PM221-MIP', },
+
+                        {'model': 'WTIIPS4',
+                         'name': 'Western Telematic (WTI IPS-4)', },
+
+                        {'model': 'ManualPCU',
+                         'name': 'Manual Administrator Operation (choose if model unknown)', },
+                         ]
 
     # Get all model names
     pcu_models = [type['model'] for type in GetPCUTypes()]
     for type in pcu_types:
-        protocol_types = type['pcu_protocol_types']
-        # Take this value out of the struct.
-        del type['pcu_protocol_types']
+               if 'pcu_protocol_types' in type:
+               protocol_types = type['pcu_protocol_types']
+               # Take this value out of the struct.
+               del type['pcu_protocol_types']
+               else:
+                       protocol_types = []
         if type['model'] not in pcu_models:
             # Add the name/model info into DB
             id = AddPCUType(type)
index bf45a4e..7c20ab1 100644 (file)
@@ -54,11 +54,19 @@ rm -f doc/NMAPI.html
 make -C doc NMAPI.html 
 popd
 
+pushd Monitor
+# beware that making the pdf file somehow overwrites the html
+make -C docs Monitor.pdf 
+rm -f docs/Monitor.html
+make -C docs Monitor.html 
+popd
+
 %install
 
 for ext in pdf html; do
     install -D -m 444 PLCAPI/doc/PLCAPI.$ext $RPM_BUILD_ROOT/var/www/html/planetlab/doc/PLCAPI.$ext
     install -D -m 444 NodeManager/doc/NMAPI.$ext $RPM_BUILD_ROOT/var/www/html/planetlab/doc/NMAPI.$ext
+    install -D -m 444 Monitor/docs/Monitor.$ext $RPM_BUILD_ROOT/var/www/html/planetlab/doc/Monitor.$ext
 done
 
 ./MyPLC/docbook2drupal.sh "PLC API Documentation (%{pldistro})" \
@@ -67,6 +75,9 @@ done
 ./MyPLC/docbook2drupal.sh "Node Manager API Documentation (%{pldistro})" \
     $RPM_BUILD_ROOT/var/www/html/planetlab/doc/NMAPI.html \
     $RPM_BUILD_ROOT/var/www/html/planetlab/doc/NMAPI.php 
+./MyPLC/docbook2drupal.sh "Monitor API Documentation (%{pldistro})" \
+    $RPM_BUILD_ROOT/var/www/html/planetlab/doc/Monitor.html \
+    $RPM_BUILD_ROOT/var/www/html/planetlab/doc/Monitor.php 
 
 %clean
 rm -rf $RPM_BUILD_ROOT