meta-flow: Correctly set destination MAC in mf_set_flow_value().
[sliver-openvswitch.git] / INSTALL.Linux
index 3088f8c..da992b5 100644 (file)
@@ -3,12 +3,11 @@
 
 This document describes how to build and install Open vSwitch on a
 generic Linux host.  If you want to install Open vSwitch on a Citrix
-XenServer version 5.5.0, see INSTALL.XenServer instead.
+XenServer, see INSTALL.XenServer instead.
 
-This version of Open vSwitch should be built manually with "configure"
-and "make".  Debian packaging for Open vSwitch is also included, but
-they have not been recently tested, and so Debian packages are not a
-recommended way to use this version of Open vSwitch.
+This version of Open vSwitch may be built manually with "configure"
+and "make", as described below.  You may also build Debian packages by
+running "dpkg-buildpackage".
 
 Build Requirements
 ------------------
@@ -21,11 +20,14 @@ you will need the following software:
     - The GNU C compiler.  We generally test with version 4.1, 4.2, or
       4.3.
 
+    - pkg-config.  We test with version 0.22.
+
     - libssl, from OpenSSL, is optional but recommended if you plan to
       connect the Open vSwitch to an OpenFlow controller.  libssl is
       required to establish confidentiality and authenticity in the
-      connections from an Open vSwitch to an OpenFlow controller.  To
-      enable, configure with --enable-ssl=yes.
+      connections from an Open vSwitch to an OpenFlow controller.  If
+      libssl is installed, then Open vSwitch will automatically build
+      with support for it.
 
 To compile the kernel module, you must also install the following.  If
 you cannot build or install the kernel module, you may use the
@@ -44,14 +46,17 @@ INSTALL.userspace for more information.
       bridge") before starting the datapath.
 
       For optional support of ingress policing, you must enable kernel
-      configuration options NET_CLS_ACT, NET_CLS_U32, NET_SCH_INGRESS,
-      and NET_ACT_POLICE, either built-in or as modules.
-      (NET_CLS_POLICE is obsolete and not needed.)
+      configuration options NET_CLS_BASIC, NET_SCH_INGRESS, and
+      NET_ACT_POLICE, either built-in or as modules.  (NET_CLS_POLICE is
+      obsolete and not needed.)
 
       If GRE tunneling is being used it is recommended that the kernel
       be compiled with IPv6 support (CONFIG_IPV6).  This allows for
       special handling (such as path MTU discovery) of IPv6 packets.
 
+      To configure HTB or HFSC quality of service with Open vSwitch,
+      you must enable the respective configuration options.
+
       To use Open vSwitch support for TAP devices, you must enable
       CONFIG_TUN.
 
@@ -65,15 +70,13 @@ INSTALL.userspace for more information.
       infrastructure.
 
 If you are working from a Git tree or snapshot (instead of from a
-distribution tarball), or if you modify the Open vSwitch build system,
-you will also need the following software:
+distribution tarball), or if you modify the Open vSwitch build system
+or the database schema, you will also need the following software:
 
     - Autoconf version 2.64 or later.
 
     - Automake version 1.10 or later.
 
-    - pkg-config.  We test with version 0.22.
-
     - Python 2.x, for x >= 4.
 
 If you modify the ovsdbmonitor tool, then you will also need the
@@ -81,12 +84,22 @@ following:
 
     - pyuic4 from PyQt4 (http://www.riverbankcomputing.co.uk).
 
+To run the unit tests, you also need:
+
+    - Perl.  Version 5.10.1 is known to work.  Earlier versions should
+      also work.
+
 If you modify the vswitchd database schema, then the E-R diagram in
 the ovs-vswitchd.conf.db(5) manpage will be updated properly only if
 you have the following:
 
     - "dot" from graphviz (http://www.graphviz.org/).
 
+    - Perl.  Version 5.10.1 is known to work.  Earlier versions should
+      also work.
+
+    - Python 2.x, for x >= 4.
+
 Installation Requirements
 -------------------------
 
@@ -104,15 +117,10 @@ following software:
       iproute2 (part of all major distributions and available at
       http://www.linux-foundation.org/en/Net:Iproute2).
 
-    - For debugging purposes, Open vSwitch expects that "tcpdump" is
-      installed as /usr/sbin/tcpdump.  If tcpdump is not installed, or
-      if it is installed in a different location, then some Open
-      vSwitch log messages will not be as detailed.
-
 You should ensure that /dev/urandom exists.  To support TAP devices,
 you must also ensure that /dev/net/tun exists.
 
-To run the ovsdmonitor tool, the machine must also have the following
+To run the ovsdbmonitor tool, the machine must also have the following
 software:
 
     - Python 2.x, for x >= 4.
@@ -158,18 +166,18 @@ Prerequisites section, follow the procedure below to build.
 
    To build the Linux kernel module, so that you can run the
    kernel-based switch, pass the location of the kernel build
-   directory on --with-l26.  For example, to build for a running
-   instance of Linux 2.6:
+   directory on --with-linux.  For example, to build for a running
+   instance of Linux:
 
-      % ./configure --with-l26=/lib/modules/`uname -r`/build
+      % ./configure --with-linux=/lib/modules/`uname -r`/build
 
    If you wish to build the kernel module for an architecture other
    than the architecture of the machine used for the build, you may
    specify the kernel architecture string using the KARCH variable
    when invoking the configure script.  For example, to build for MIPS
-   with Linux 2.6:
+   with Linux:
 
-      % ./configure --with-l26=/path/to/linux-2.6 KARCH=mips
+      % ./configure --with-linux=/path/to/linux KARCH=mips
 
    The configure script accepts a number of other options and honors
    additional environment variables.  For a full list, invoke
@@ -186,7 +194,7 @@ Prerequisites section, follow the procedure below to build.
 
 6. If you built kernel modules, you may load them with "insmod", e.g.:
 
-      % insmod datapath/linux-2.6/openvswitch_mod.ko
+      % insmod datapath/linux/openvswitch_mod.ko
 
    You may need to specify a full path to insmod, e.g. /sbin/insmod.
    To verify that the modules have been loaded, run "/sbin/lsmod" and
@@ -227,9 +235,22 @@ Prerequisites section, follow the procedure below to build.
         module loading, please include the output from the "dmesg" and
         "modinfo" commands mentioned above.
 
+   There is an optional module parameter to openvswitch_mod.ko called
+   vlan_tso that enables TCP segmentation offload over VLANs on NICs
+   that support it. Many drivers do not expose support for TSO on VLANs
+   in a way that Open vSwitch can use but there is no way to detect
+   whether this is the case. If you know that your particular driver can
+   handle it (for example by testing sending large TCP packets over VLANs)
+   then passing in a value of 1 may improve performance. Modules built for
+   Linux kernels 2.6.37 and later, as well as specially patched versions
+   of earlier kernels, do not need this and do not have this parameter. If
+   you do not understand what this means or do not know if your driver
+   will work, do not set this.
+
 7. Initialize the configuration database using ovsdb-tool, e.g.:
 
-      % ovsdb-tool create /usr/local/etc/ovs-vswitchd.conf.db vswitchd/vswitch.ovsschema
+      % mkdir -p /usr/local/etc/openvswitch
+      % ovsdb-tool create /usr/local/etc/openvswitch/conf.db vswitchd/vswitch.ovsschema
 
 Startup
 =======
@@ -242,12 +263,15 @@ installation, above, to listen on a Unix domain socket, to connect to
 any managers specified in the database itself, and to use the SSL
 configuration in the database:
 
-      % ovsdb-server /usr/local/etc/ovs-vswitchd.conf.db \
-                      --remote=punix:/usr/local/var/run/openvswitch/db.sock \
-                      --remote=db:Open_vSwitch,managers \
-                      --private-key=db:SSL,private_key \
-                      --certificate=db:SSL,certificate \
-                      --bootstrap-ca-cert=db:SSL,ca_cert
+      % ovsdb-server --remote=punix:/usr/local/var/run/openvswitch/db.sock \
+                     --remote=db:Open_vSwitch,manager_options \
+                     --private-key=db:SSL,private_key \
+                     --certificate=db:SSL,certificate \
+                     --bootstrap-ca-cert=db:SSL,ca_cert \
+                     --pidfile --detach
+
+(If you built Open vSwitch without SSL support, then omit
+--private-key, --certificate, and --bootstrap-ca-cert.)
 
 Then initialize the database using ovs-vsctl.  This is only
 necessary the first time after you create the database with
@@ -258,7 +282,7 @@ ovsdb-tool (but running it at any time is harmless):
 Then start the main Open vSwitch daemon, telling it to connect to the
 same Unix domain socket:
 
-      % ovs-vswitchd unix:/usr/local/var/run/openvswitch/db.sock
+      % ovs-vswitchd --pidfile --detach
 
 Now you may use ovs-vsctl to set up bridges and other Open vSwitch
 features.  For example, to create a bridge named br0 and add ports
@@ -270,6 +294,33 @@ eth0 and vif1.0 to it:
 
 Please refer to ovs-vsctl(8) for more details.
 
+Upgrading
+=========
+
+When you upgrade Open vSwitch from one version to another, you should
+also upgrade the database schema:
+
+1. Stop the Open vSwitch daemons, e.g.:
+
+      % kill `cd /usr/local/var/run && cat ovsdb-server.pid ovs-vswitchd.pid`
+
+2. Install the new Open vSwitch release.
+
+3. Upgrade the database, in one of the following two ways:
+
+      - If there is no important data in your database, then you may
+        delete the database file and recreate it with ovsdb-tool,
+        following the instructions under "Building and Installing Open
+        vSwitch for Linux".
+
+      - If you want to preserve the contents of your database, back it
+        up first, then use "ovsdb-tool convert" to upgrade it, e.g.:
+
+        % ovsdb-tool convert /usr/local/etc/openvswitch/conf.db vswitchd/vswitch.ovsschema
+
+4. Start the Open vSwitch daemons as described under "Building and
+   Installing Open vSwitch for Linux" above.
+
 Bug Reporting
 -------------