meta-flow: Correctly set destination MAC in mf_set_flow_value().
[sliver-openvswitch.git] / vswitchd / ovs-vswitchd.8.in
index 516e6da..e3cc8db 100644 (file)
@@ -108,14 +108,30 @@ how to configure Open vSwitch.
 .SS "GENERAL COMMANDS"
 .IP "\fBexit\fR"
 Causes \fBovs\-vswitchd\fR to gracefully terminate.
+.IP "\fBcoverage/log\fR"
+Logs coverage counters at level warn.
 .IP "\fBqos/show\fR \fIinterface\fR"
 Queries the kernel for Quality of Service configuration and statistics
 associated with the given \fIinterface\fR.
-.IP "\fBcfm/show\fR \fIinterface\fR"
+.IP "\fBcfm/show\fR [\fIinterface\fR]"
 Displays detailed information about Connectivity Fault Management
-configured on \fIinterface\fR.
+configured on \fIinterface\fR.  If \fIinterface\fR is not specified,
+then displays detailed information about all interfaces with CFM
+enabled.
+.IP "\fBcfm/set-fault\fR [\fIinterface\fR] \fIstatus\fR"
+Force the fault status of the CFM module on \fIinterface\fR (or all
+interfaces if none is given) to be \fIstatus\fR.  \fIstatus\fR can be
+"true", "false", or "normal" which reverts to the standard behavior.
+.IP "\fBstp/tcn\fR [\fIbridge\fR]"
+Forces a topology change event on \fIbridge\fR if it's running STP.  This
+may cause it to send Topology Change Notifications to its peers and flush
+its MAC table..  If no \fIbridge\fR is given, forces a topology change
+event on all bridges.
 .SS "BRIDGE COMMANDS"
 These commands manage bridges.
+.IP "\fBfdb/flush\fR [\fIbridge\fR]"
+Flushes \fIbridge\fR MAC address learning table, or all learning tables
+if no \fIbridge\fR is given.
 .IP "\fBfdb/show\fR \fIbridge\fR"
 Lists each MAC address/VLAN pair learned by the specified \fIbridge\fR,
 along with the port on which it was learned and the age of the entry,
@@ -181,12 +197,14 @@ status of \fIslave\fR changes.
 Returns the hash value which would be used for \fImac\fR with \fIvlan\fR
 and \fIbasis\fR if specified.
 .
-.IP "\fBlacp/show\fR \fIport\fR"
+.IP "\fBlacp/show\fR [\fIport\fR]"
 Lists all of the LACP related information about the given \fIport\fR:
 active or passive, aggregation key, system id, and system priority.  Also
 lists information about each slave: whether it is enabled or disabled,
 whether it is attached or detached, port id and priority, actor
-information, and partner information.
+information, and partner information.  If \fIport\fR is not specified,
+then displays detailed information about all interfaces with CFM
+enabled.
 .
 .so ofproto/ofproto-unixctl.man
 .so lib/vlog-unixctl.man