meta-flow: Correctly set destination MAC in mf_set_flow_value().
[sliver-openvswitch.git] / vswitchd / ovs-vswitchd.8.in
index 822c0f2..e3cc8db 100644 (file)
 ovs\-vswitchd \- Open vSwitch daemon
 .
 .SH SYNOPSIS
-.B ovs\-vswitchd
-\fIdatabase\fR
+\fBovs\-vswitchd \fR[\fIdatabase\fR]
 .
 .SH DESCRIPTION
 A daemon that manages and controls any number of Open vSwitch switches
 on the local machine.
 .PP
-The mandatory \fIdatabase\fR argument normally takes the form
-\fBunix:\fIfile\fR, where \fIfile\fR is the name of a Unix domain
-socket on which \fBovsdb\-server\fR is listening.  However, all of the
-following forms are accepted:
+The \fIdatabase\fR argument specifies how \fBovs\-vswitchd\fR connects
+to \fBovsdb\-server\fR.  The default is \fBunix:@RUNDIR@/db.sock\fR.
+The following forms are accepted:
 .so ovsdb/remote-active.man
 .so ovsdb/remote-passive.man
 .PP
@@ -67,9 +65,6 @@ Only a single instance of \fBovs\-vswitchd\fR is intended to run at a time.
 A single \fBovs\-vswitchd\fR can manage any number of switch instances, up
 to the maximum number of supported Open vSwitch datapaths.
 .PP
-\fBovs\-vswitchd\fR provides all the features of \fBovs-openflowd\fR,
-and more.  Do not run both daemons at the same time.
-.PP
 \fBovs\-vswitchd\fR does all the necessary management of Open vSwitch datapaths
 itself.  Thus, external tools, such \fBovs\-dpctl\fR(8), are not needed for
 managing datapaths in conjunction with \fBovs\-vswitchd\fR, and their use
@@ -93,15 +88,10 @@ only allow privileged users, such as the superuser, to use it.
 \fBovs\-vswitchd\fR emits a log message if \fBmlockall()\fR is
 unavailable or unsuccessful.
 .
-.IP "\fB\-\-fake\-proc\-net\fR"
-Causes \fBovs\-vswitchd\fR to simulate some files in \fB/proc/net/vlan\fR
-and \fB/proc/net/bonding\fR that some legacy software expects to
-exist.  This option should only be used if such legacy software is
-actually in use.  It requires the \fBbrcompat_mod.ko\fR kernel module
-to be loaded.
-.IP
-On non-Linux hosts, this option is accepted but has no effect.
-.
+.ds DD \
+\fBovs\-vswitchd\fR detaches only after it has connected to the \
+database, retrieved the initial configuration, and set up that \
+configuration.
 .so lib/daemon.man
 .SS "Public Key Infrastructure Options"
 .so lib/ssl.man
@@ -118,8 +108,30 @@ how to configure Open vSwitch.
 .SS "GENERAL COMMANDS"
 .IP "\fBexit\fR"
 Causes \fBovs\-vswitchd\fR to gracefully terminate.
+.IP "\fBcoverage/log\fR"
+Logs coverage counters at level warn.
+.IP "\fBqos/show\fR \fIinterface\fR"
+Queries the kernel for Quality of Service configuration and statistics
+associated with the given \fIinterface\fR.
+.IP "\fBcfm/show\fR [\fIinterface\fR]"
+Displays detailed information about Connectivity Fault Management
+configured on \fIinterface\fR.  If \fIinterface\fR is not specified,
+then displays detailed information about all interfaces with CFM
+enabled.
+.IP "\fBcfm/set-fault\fR [\fIinterface\fR] \fIstatus\fR"
+Force the fault status of the CFM module on \fIinterface\fR (or all
+interfaces if none is given) to be \fIstatus\fR.  \fIstatus\fR can be
+"true", "false", or "normal" which reverts to the standard behavior.
+.IP "\fBstp/tcn\fR [\fIbridge\fR]"
+Forces a topology change event on \fIbridge\fR if it's running STP.  This
+may cause it to send Topology Change Notifications to its peers and flush
+its MAC table..  If no \fIbridge\fR is given, forces a topology change
+event on all bridges.
 .SS "BRIDGE COMMANDS"
 These commands manage bridges.
+.IP "\fBfdb/flush\fR [\fIbridge\fR]"
+Flushes \fIbridge\fR MAC address learning table, or all learning tables
+if no \fIbridge\fR is given.
 .IP "\fBfdb/show\fR \fIbridge\fR"
 Lists each MAC address/VLAN pair learned by the specified \fIbridge\fR,
 along with the port on which it was learned and the age of the entry,
@@ -139,12 +151,12 @@ since it is not allowed to modify or override them.
 .SS "BOND COMMANDS"
 These commands manage bonded ports on an Open vSwitch's bridges.  To
 understand some of these commands, it is important to understand a
-detail of the bonding implementation called ``MAC hashing.''  Instead
-of directly assigning Ethernet source addresses to slaves, the bonding
-implementation computes a function that maps an 48-bit Ethernet source
-addresses into an 8-bit value (a ``MAC hash'' value).  All of the
-Ethernet addresses that map to a single 8-bit value are then assigned
-to a single slave.
+detail of the bonding implementation called ``source load balancing''
+(SLB).  Instead of directly assigning Ethernet source addresses to
+slaves, the bonding implementation computes a function that maps an
+48-bit Ethernet source addresses into an 8-bit value (a ``MAC hash''
+value).  All of the Ethernet addresses that map to a single 8-bit
+value are then assigned to a single slave.
 .IP "\fBbond/list\fR"
 Lists all of the bonds, and their slaves, on each bridge.
 .
@@ -155,11 +167,13 @@ lists information about each slave: whether it is enabled or disabled,
 the time to completion of an updelay or downdelay if one is in
 progress, whether it is the active slave, the MAC hashes assigned to
 the slave, and the MAC learning table entries that hash to each MAC.
+Any LACP information related to this bond may be found using the
+\fBlacp/show\fR command.
 .IP "\fBbond/migrate\fR \fIport\fR \fIhash\fR \fIslave\fR"
-Assigns a given MAC hash to a new slave.  \fIport\fR specifies the
-bond port, \fIhash\fR the MAC hash to be migrated (as a decimal
-number between 0 and 255), and \fIslave\fR the new slave to be
-assigned.
+Only valid for SLB bonds.  Assigns a given MAC hash to a new slave.
+\fIport\fR specifies the bond port, \fIhash\fR the MAC hash to be
+migrated (as a decimal number between 0 and 255), and \fIslave\fR the
+new slave to be assigned.
 .IP
 The reassignment is not permanent: rebalancing or fail-over will
 cause the MAC hash to be shifted to a new slave in the usual
@@ -179,9 +193,18 @@ updelay (or downdelay).
 .IP
 This setting is not permanent: it persists only until the carrier
 status of \fIslave\fR changes.
-.IP "\fBbond/hash\fR \fImac\fR [\fIvlan\fR]"
+.IP "\fBbond/hash\fR \fImac\fR [\fIvlan\fR] [\fIbasis\fR]"
 Returns the hash value which would be used for \fImac\fR with \fIvlan\fR
-if specified.
+and \fIbasis\fR if specified.
+.
+.IP "\fBlacp/show\fR [\fIport\fR]"
+Lists all of the LACP related information about the given \fIport\fR:
+active or passive, aggregation key, system id, and system priority.  Also
+lists information about each slave: whether it is enabled or disabled,
+whether it is attached or detached, port id and priority, actor
+information, and partner information.  If \fIport\fR is not specified,
+then displays detailed information about all interfaces with CFM
+enabled.
 .
 .so ofproto/ofproto-unixctl.man
 .so lib/vlog-unixctl.man