VServer 1.9.2 (patch-2.6.8.1-vs1.9.2.diff)
[linux-2.6.git] / drivers / scsi / Kconfig
1 menu "SCSI device support"
2
3 config SCSI
4         tristate "SCSI device support"
5         ---help---
6           If you want to use a SCSI hard disk, SCSI tape drive, SCSI CD-ROM or
7           any other SCSI device under Linux, say Y and make sure that you know
8           the name of your SCSI host adapter (the card inside your computer
9           that "speaks" the SCSI protocol, also called SCSI controller),
10           because you will be asked for it.
11
12           You also need to say Y here if you have a device which speaks
13           the SCSI protocol.  Examples of this include the parallel port
14           version of the IOMEGA ZIP drive, USB storage devices, Fibre
15           Channel, FireWire storage and the IDE-SCSI emulation driver.
16
17           To compile this driver as a module, choose M here and read
18           <file:Documentation/scsi/scsi.txt>.
19           The module will be called scsi_mod.
20
21           However, do not compile this as a module if your root file system
22           (the one containing the directory /) is located on a SCSI device.
23
24 config SCSI_PROC_FS
25         bool "legacy /proc/scsi/ support"
26         depends on SCSI && PROC_FS
27         default y
28         ---help---
29           This option enables support for the various files in
30           /proc/scsi.  In Linux 2.6 this has been superceeded by
31           files in sysfs but many legacy applications rely on this.
32
33           If unusure say Y.
34
35 comment "SCSI support type (disk, tape, CD-ROM)"
36         depends on SCSI
37
38 config BLK_DEV_SD
39         tristate "SCSI disk support"
40         depends on SCSI
41         ---help---
42           If you want to use SCSI hard disks, Fibre Channel disks,
43           USB storage or the SCSI or parallel port version of
44           the IOMEGA ZIP drive, say Y and read the SCSI-HOWTO,
45           the Disk-HOWTO and the Multi-Disk-HOWTO, available from
46           <http://www.tldp.org/docs.html#howto>. This is NOT for SCSI
47           CD-ROMs.
48
49           To compile this driver as a module, choose M here and read
50           <file:Documentation/scsi/scsi.txt>.
51           The module will be called sd_mod.
52
53           Do not compile this driver as a module if your root file system
54           (the one containing the directory /) is located on a SCSI disk.
55           In this case, do not compile the driver for your SCSI host adapter
56           (below) as a module either.
57
58 config CHR_DEV_ST
59         tristate "SCSI tape support"
60         depends on SCSI
61         ---help---
62           If you want to use a SCSI tape drive under Linux, say Y and read the
63           SCSI-HOWTO, available from
64           <http://www.tldp.org/docs.html#howto>, and
65           <file:Documentation/scsi/st.txt> in the kernel source.  This is NOT
66           for SCSI CD-ROMs.
67
68           To compile this driver as a module, choose M here and read
69           <file:Documentation/scsi/scsi.txt>. The module will be called st.
70
71 config CHR_DEV_OSST
72         tristate "SCSI OnStream SC-x0 tape support"
73         depends on SCSI
74         ---help---
75           The OnStream SC-x0 SCSI tape drives can not be driven by the
76           standard st driver, but instead need this special osst driver and
77           use the  /dev/osstX char device nodes (major 206).  Via usb-storage
78           and ide-scsi, you may be able to drive the USB-x0 and DI-x0 drives
79           as well.  Note that there is also a second generation of OnStream
80           tape drives (ADR-x0) that supports the standard SCSI-2 commands for
81           tapes (QIC-157) and can be driven by the standard driver st.
82           For more information, you may have a look at the SCSI-HOWTO
83           <http://www.tldp.org/docs.html#howto>  and
84           <file:Documentation/scsi/osst.txt>  in the kernel source.
85           More info on the OnStream driver may be found on
86           <http://linux1.onstream.nl/test/>
87           Please also have a look at the standard st docu, as most of it
88           applies to osst as well.
89
90           To compile this driver as a module, choose M here and read
91           <file:Documentation/scsi/scsi.txt>. The module will be called osst.
92
93 config BLK_DEV_SR
94         tristate "SCSI CDROM support"
95         depends on SCSI
96         ---help---
97           If you want to use a SCSI or FireWire CD-ROM under Linux,
98           say Y and read the SCSI-HOWTO and the CDROM-HOWTO at
99           <http://www.tldp.org/docs.html#howto>. Also make sure to say
100           Y or M to "ISO 9660 CD-ROM file system support" later.
101
102           To compile this driver as a module, choose M here and read
103           <file:Documentation/scsi/scsi.txt>.
104           The module will be called sr_mod.
105
106 config BLK_DEV_SR_VENDOR
107         bool "Enable vendor-specific extensions (for SCSI CDROM)"
108         depends on BLK_DEV_SR
109         help
110           This enables the usage of vendor specific SCSI commands. This is
111           required to support multisession CDs with old NEC/TOSHIBA cdrom
112           drives (and HP Writers). If you have such a drive and get the first
113           session only, try saying Y here; everybody else says N.
114
115 config CHR_DEV_SG
116         tristate "SCSI generic support"
117         depends on SCSI
118         ---help---
119           If you want to use SCSI scanners, synthesizers or CD-writers or just
120           about anything having "SCSI" in its name other than hard disks,
121           CD-ROMs or tapes, say Y here. These won't be supported by the kernel
122           directly, so you need some additional software which knows how to
123           talk to these devices using the SCSI protocol:
124
125           For scanners, look at SANE (<http://www.mostang.com/sane/>). For CD
126           writer software look at Cdrtools
127           (<http://www.fokus.gmd.de/research/cc/glone/employees/joerg.schilling/private/cdrecord.html>)
128           and for burning a "disk at once": CDRDAO
129           (<http://cdrdao.sourceforge.net/>). Cdparanoia is a high
130           quality digital reader of audio CDs (<http://www.xiph.org/paranoia/>).
131           For other devices, it's possible that you'll have to write the
132           driver software yourself. Please read the file
133           <file:Documentation/scsi/scsi-generic.txt> for more information.
134
135           To compile this driver as a module, choose M here and read
136           <file:Documentation/scsi/scsi.txt>. The module will be called sg.
137
138           If unsure, say N.
139
140 comment "Some SCSI devices (e.g. CD jukebox) support multiple LUNs"
141         depends on SCSI
142
143 config SCSI_MULTI_LUN
144         bool "Probe all LUNs on each SCSI device"
145         depends on SCSI
146         help
147           If you have a SCSI device that supports more than one LUN (Logical
148           Unit Number), e.g. a CD jukebox, and only one LUN is detected, you
149           can say Y here to force the SCSI driver to probe for multiple LUNs.
150           A SCSI device with multiple LUNs acts logically like multiple SCSI
151           devices. The vast majority of SCSI devices have only one LUN, and
152           so most people can say N here. The max_luns boot/module parameter 
153           allows to override this setting.
154
155 config SCSI_CONSTANTS
156         bool "Verbose SCSI error reporting (kernel size +=12K)"
157         depends on SCSI
158         help
159           The error messages regarding your SCSI hardware will be easier to
160           understand if you say Y here; it will enlarge your kernel by about
161           12 KB. If in doubt, say Y.
162
163 config SCSI_LOGGING
164         bool "SCSI logging facility"
165         depends on SCSI
166         ---help---
167           This turns on a logging facility that can be used to debug a number
168           of SCSI related problems.
169
170           If you say Y here, no logging output will appear by default, but you
171           can enable logging by saying Y to "/proc file system support" and
172           "Sysctl support" below and executing the command
173
174           echo "scsi log token [level]" > /proc/scsi/scsi
175
176           at boot time after the /proc file system has been mounted.
177
178           There are a number of things that can be used for 'token' (you can
179           find them in the source: <file:drivers/scsi/scsi.c>), and this
180           allows you to select the types of information you want, and the
181           level allows you to select the level of verbosity.
182
183           If you say N here, it may be harder to track down some types of SCSI
184           problems. If you say Y here your kernel will be somewhat larger, but
185           there should be no noticeable performance impact as long as you have
186           logging turned off.
187
188 menu "SCSI Transport Attributes"
189         depends on SCSI
190
191 config SCSI_SPI_ATTRS
192         tristate "Parallel SCSI (SPI) Transport Attributes"
193         depends on SCSI
194         help
195           If you wish to export transport-specific information about
196           each attached SCSI device to sysfs, say Y.  Otherwise, say N.
197
198 config SCSI_FC_ATTRS
199         tristate "FiberChannel Transport Attributes"
200         depends on SCSI
201         help
202           If you wish to export transport-specific information about
203           each attached FiberChannel device to sysfs, say Y.
204           Otherwise, say N.
205
206 endmenu
207
208 menu "SCSI low-level drivers"
209         depends on SCSI!=n
210
211 config SGIWD93_SCSI
212         tristate "SGI WD93C93 SCSI Driver"
213         depends on SGI_IP22 && SCSI
214         help
215           If you have a Western Digital WD93 SCSI controller on
216           an SGI MIPS system, say Y.  Otherwise, say N.
217
218 config SCSI_DECNCR
219         tristate "DEC NCR53C94 Scsi Driver"
220         depends on DECSTATION && TC && SCSI
221         help
222           Say Y here to support the NCR53C94 SCSI controller chips on IOASIC
223           based TURBOchannel DECstations and TURBOchannel PMAZ-A cards.
224
225 config SCSI_DECSII
226         tristate "DEC SII Scsi Driver"
227         depends on DECSTATION && SCSI
228
229 config BLK_DEV_3W_XXXX_RAID
230         tristate "3ware 5/6/7/8xxx ATA-RAID support"
231         depends on PCI && SCSI
232         help
233           3ware is the only hardware ATA-Raid product in Linux to date.
234           This card is 2,4, or 8 channel master mode support only.
235           SCSI support required!!!
236
237           <http://www.3ware.com/>
238
239           Please read the comments at the top of
240           <file:drivers/scsi/3w-xxxx.c>.
241
242 config SCSI_3W_9XXX
243         tristate "3ware 9xxx SATA-RAID support"
244         depends on PCI && SCSI
245         help
246           This driver supports the 9000 series 3ware SATA-RAID cards.
247
248           <http://www.amcc.com>
249
250           Please read the comments at the top of
251           <file:drivers/scsi/3w-9xxx.c>.
252
253 config SCSI_7000FASST
254         tristate "7000FASST SCSI support"
255         depends on ISA && SCSI
256         help
257           This driver supports the Western Digital 7000 SCSI host adapter
258           family.  Some information is in the source:
259           <file:drivers/scsi/wd7000.c>.
260
261           To compile this driver as a module, choose M here: the
262           module will be called wd7000.
263
264 config SCSI_ACARD
265         tristate "ACARD SCSI support"
266         depends on PCI && SCSI
267         help
268           This driver supports the ACARD 870U/W SCSI host adapter.
269
270           To compile this driver as a module, choose M here: the
271           module will be called atp870u.
272
273 config SCSI_AHA152X
274         tristate "Adaptec AHA152X/2825 support"
275         depends on ISA && SCSI && !64BIT
276         ---help---
277           This is a driver for the AHA-1510, AHA-1520, AHA-1522, and AHA-2825
278           SCSI host adapters. It also works for the AVA-1505, but the IRQ etc.
279           must be manually specified in this case.
280
281           It is explained in section 3.3 of the SCSI-HOWTO, available from
282           <http://www.tldp.org/docs.html#howto>. You might also want to
283           read the file <file:Documentation/scsi/aha152x.txt>.
284
285           To compile this driver as a module, choose M here: the
286           module will be called aha152x.
287
288 config SCSI_AHA1542
289         tristate "Adaptec AHA1542 support"
290         depends on ISA && SCSI
291         ---help---
292           This is support for a SCSI host adapter.  It is explained in section
293           3.4 of the SCSI-HOWTO, available from
294           <http://www.tldp.org/docs.html#howto>.  Note that Trantor was
295           purchased by Adaptec, and some former Trantor products are being
296           sold under the Adaptec name.  If it doesn't work out of the box, you
297           may have to change some settings in <file:drivers/scsi/aha1542.h>.
298
299           To compile this driver as a module, choose M here: the
300           module will be called aha1542.
301
302 config SCSI_AHA1740
303         tristate "Adaptec AHA1740 support"
304         depends on EISA && SCSI
305         ---help---
306           This is support for a SCSI host adapter.  It is explained in section
307           3.5 of the SCSI-HOWTO, available from
308           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
309           of the box, you may have to change some settings in
310           <file:drivers/scsi/aha1740.h>.
311
312           To compile this driver as a module, choose M here: the
313           module will be called aha1740.
314
315 config SCSI_AACRAID
316         tristate "Adaptec AACRAID support (EXPERIMENTAL)"
317         depends on EXPERIMENTAL && SCSI && PCI
318
319 source "drivers/scsi/aic7xxx/Kconfig.aic7xxx"
320
321 config SCSI_AIC7XXX_OLD
322         tristate "Adaptec AIC7xxx support (old driver)"
323         depends on SCSI
324         help
325           WARNING This driver is an older aic7xxx driver and is no longer
326           under active development.  Adaptec, Inc. is writing a new driver to
327           take the place of this one, and it is recommended that whenever
328           possible, people should use the new Adaptec written driver instead
329           of this one.  This driver will eventually be phased out entirely.
330
331           This is support for the various aic7xxx based Adaptec SCSI
332           controllers. These include the 274x EISA cards; 284x VLB cards;
333           2902, 2910, 293x, 294x, 394x, 3985 and several other PCI and
334           motherboard based SCSI controllers from Adaptec. It does not support
335           the AAA-13x RAID controllers from Adaptec, nor will it likely ever
336           support them. It does not support the 2920 cards from Adaptec that
337           use the Future Domain SCSI controller chip. For those cards, you
338           need the "Future Domain 16xx SCSI support" driver.
339
340           In general, if the controller is based on an Adaptec SCSI controller
341           chip from the aic777x series or the aic78xx series, this driver
342           should work. The only exception is the 7810 which is specifically
343           not supported (that's the RAID controller chip on the AAA-13x
344           cards).
345
346           Note that the AHA2920 SCSI host adapter is *not* supported by this
347           driver; choose "Future Domain 16xx SCSI support" instead if you have
348           one of those.
349
350           Information on the configuration options for this controller can be
351           found by checking the help file for each of the available
352           configuration options. You should read
353           <file:Documentation/scsi/aic7xxx_old.txt> at a minimum before
354           contacting the maintainer with any questions.  The SCSI-HOWTO,
355           available from <http://www.tldp.org/docs.html#howto>, can also
356           be of great help.
357
358           To compile this driver as a module, choose M here: the
359           module will be called aic7xxx_old.
360
361 source "drivers/scsi/aic7xxx/Kconfig.aic79xx"
362
363 # All the I2O code and drivers do not seem to be 64bit safe.
364 config SCSI_DPT_I2O
365         tristate "Adaptec I2O RAID support "
366         depends on !64BIT && SCSI && PCI
367         help
368           This driver supports all of Adaptec's I2O based RAID controllers as 
369           well as the DPT SmartRaid V cards.  This is an Adaptec maintained
370           driver by Deanna Bonds.  See <file:Documentation/scsi/dpti.txt>.
371
372           To compile this driver as a module, choose M here: the
373           module will be called dpt_i2o.
374
375 config SCSI_ADVANSYS
376         tristate "AdvanSys SCSI support"
377         depends on (ISA || EISA || PCI) && SCSI && BROKEN
378         help
379           This is a driver for all SCSI host adapters manufactured by
380           AdvanSys. It is documented in the kernel source in
381           <file:drivers/scsi/advansys.c>.
382
383           To compile this driver as a module, choose M here: the
384           module will be called advansys.
385
386 config SCSI_IN2000
387         tristate "Always IN2000 SCSI support"
388         depends on ISA && SCSI
389         help
390           This is support for an ISA bus SCSI host adapter.  You'll find more
391           information in <file:Documentation/scsi/in2000.txt>. If it doesn't work
392           out of the box, you may have to change the jumpers for IRQ or
393           address selection.
394
395           To compile this driver as a module, choose M here: the
396           module will be called in2000.
397
398 config SCSI_MEGARAID
399         tristate "AMI MegaRAID support"
400         depends on PCI && SCSI
401         help
402           This driver supports the AMI MegaRAID 418, 428, 438, 466, 762, 490
403           and 467 SCSI host adapters.
404
405           To compile this driver as a module, choose M here: the
406           module will be called megaraid.
407
408 config SCSI_SATA
409         bool "Serial ATA (SATA) support"
410         depends on SCSI && EXPERIMENTAL
411         help
412           This driver family supports Serial ATA host controllers
413           and devices.
414
415           If unsure, say N.
416
417 config SCSI_SATA_SVW
418         tristate "ServerWorks Frodo / Apple K2 SATA support (EXPERIMENTAL)"
419         depends on SCSI_SATA && PCI && EXPERIMENTAL
420         help
421           This option enables support for Broadcom/Serverworks/Apple K2
422           SATA support.
423
424           If unsure, say N.
425
426 config SCSI_ATA_PIIX
427         tristate "Intel PIIX/ICH SATA support"
428         depends on SCSI_SATA && PCI
429         help
430           This option enables support for ICH5 Serial ATA.
431           If PATA support was enabled previously, this enables
432           support for select Intel PIIX/ICH PATA host controllers.
433
434           If unsure, say N.
435
436 config SCSI_SATA_NV
437         tristate "NVIDIA SATA support"
438         depends on SCSI_SATA && PCI && EXPERIMENTAL
439         help
440           This option enables support for NVIDIA Serial ATA.
441
442           If unsure, say N.
443
444 config SCSI_SATA_PROMISE
445         tristate "Promise SATA TX2/TX4 support"
446         depends on SCSI_SATA && PCI
447         help
448           This option enables support for Promise Serial ATA TX2/TX4.
449
450           If unsure, say N.
451
452 config SCSI_SATA_SX4
453         tristate "Promise SATA SX4 support"
454         depends on SCSI_SATA && PCI && EXPERIMENTAL
455         help
456           This option enables support for Promise Serial ATA SX4.
457
458           If unsure, say N.
459
460 config SCSI_SATA_SIL
461         tristate "Silicon Image SATA support"
462         depends on SCSI_SATA && PCI && EXPERIMENTAL
463         help
464           This option enables support for Silicon Image Serial ATA.
465
466           If unsure, say N.
467
468 config SCSI_SATA_SIS
469         tristate "SiS 964/180 SATA support"
470         depends on SCSI_SATA && PCI
471         help
472           This option enables support for SiS Serial ATA 964/180.
473
474           If unsure, say N.
475
476 config SCSI_SATA_VIA
477         tristate "VIA SATA support"
478         depends on SCSI_SATA && PCI && EXPERIMENTAL
479         help
480           This option enables support for VIA Serial ATA.
481
482           If unsure, say N.
483
484 config SCSI_SATA_VITESSE
485         tristate "VITESSE VSC-7174 SATA support"
486         depends on SCSI_SATA && PCI && EXPERIMENTAL
487         help
488           This option enables support for Vitesse VSC7174 Serial ATA.
489
490           If unsure, say N.
491
492 config SCSI_BUSLOGIC
493         tristate "BusLogic SCSI support"
494         depends on (PCI || ISA || MCA) && SCSI && (BROKEN || !SPARC64)
495         ---help---
496           This is support for BusLogic MultiMaster and FlashPoint SCSI Host
497           Adapters. Consult the SCSI-HOWTO, available from
498           <http://www.tldp.org/docs.html#howto>, and the files
499           <file:Documentation/scsi/BusLogic.txt> and
500           <file:Documentation/scsi/FlashPoint.txt> for more information.
501
502           To compile this driver as a module, choose M here: the
503           module will be called BusLogic.
504
505 config SCSI_OMIT_FLASHPOINT
506         bool "Omit FlashPoint support"
507         depends on SCSI_BUSLOGIC
508         help
509           This option allows you to omit the FlashPoint support from the
510           BusLogic SCSI driver. The FlashPoint SCCB Manager code is
511           substantial, so users of MultiMaster Host Adapters may wish to omit
512           it.
513
514 #
515 # This is marked broken because it uses over 4kB of stack in
516 # just two routines:
517 #     2076  CpqTsProcessIMQEntry
518 #     2052  PeekIMQEntry
519 #
520 config SCSI_CPQFCTS
521         tristate "Compaq Fibre Channel 64-bit/66Mhz HBA support"
522         depends on PCI && SCSI && BROKEN
523         help
524           Say Y here to compile in support for the Compaq StorageWorks Fibre
525           Channel 64-bit/66Mhz Host Bus Adapter.
526
527 config SCSI_DMX3191D
528         tristate "DMX3191D SCSI support"
529         depends on PCI && SCSI
530         help
531           This is support for Domex DMX3191D SCSI Host Adapters.
532
533           To compile this driver as a module, choose M here: the
534           module will be called dmx3191d.
535
536 config SCSI_DTC3280
537         tristate "DTC3180/3280 SCSI support"
538         depends on ISA && SCSI
539         help
540           This is support for DTC 3180/3280 SCSI Host Adapters.  Please read
541           the SCSI-HOWTO, available from
542           <http://www.tldp.org/docs.html#howto>, and the file
543           <file:Documentation/scsi/dtc3x80.txt>.
544
545           To compile this driver as a module, choose M here: the
546           module will be called dtc.
547
548 config SCSI_EATA
549         tristate "EATA ISA/EISA/PCI (DPT and generic EATA/DMA-compliant boards) support"
550         depends on (ISA || EISA || PCI) && SCSI && (BROKEN || !SPARC64)
551         ---help---
552           This driver supports all EATA/DMA-compliant SCSI host adapters.  DPT
553           ISA and all EISA I/O addresses are probed looking for the "EATA"
554           signature. The addresses of all the PCI SCSI controllers reported
555           by the PCI subsystem are probed as well.
556
557           You want to read the start of <file:drivers/scsi/eata.c> and the
558           SCSI-HOWTO, available from
559           <http://www.tldp.org/docs.html#howto>.
560
561           To compile this driver as a module, choose M here: the
562           module will be called eata.
563
564 config SCSI_EATA_TAGGED_QUEUE
565         bool "enable tagged command queueing"
566         depends on SCSI_EATA
567         help
568           This is a feature of SCSI-2 which improves performance: the host
569           adapter can send several SCSI commands to a device's queue even if
570           previous commands haven't finished yet.
571           This is equivalent to the "eata=tc:y" boot option.
572
573 config SCSI_EATA_LINKED_COMMANDS
574         bool "enable elevator sorting"
575         depends on SCSI_EATA
576         help
577           This option enables elevator sorting for all probed SCSI disks and
578           CD-ROMs. It definitely reduces the average seek distance when doing
579           random seeks, but this does not necessarily result in a noticeable
580           performance improvement: your mileage may vary...
581           This is equivalent to the "eata=lc:y" boot option.
582
583 config SCSI_EATA_MAX_TAGS
584         int "maximum number of queued commands"
585         depends on SCSI_EATA
586         default "16"
587         help
588           This specifies how many SCSI commands can be maximally queued for
589           each probed SCSI device. You should reduce the default value of 16
590           only if you have disks with buggy or limited tagged command support.
591           Minimum is 2 and maximum is 62. This value is also the window size
592           used by the elevator sorting option above. The effective value used
593           by the driver for each probed SCSI device is reported at boot time.
594           This is equivalent to the "eata=mq:8" boot option.
595
596 config SCSI_EATA_PIO
597         tristate "EATA-PIO (old DPT PM2001, PM2012A) support"
598         depends on SCSI
599         ---help---
600           This driver supports all EATA-PIO protocol compliant SCSI Host
601           Adapters like the DPT PM2001 and the PM2012A.  EATA-DMA compliant
602           host adapters could also use this driver but are discouraged from
603           doing so, since this driver only supports hard disks and lacks
604           numerous features.  You might want to have a look at the SCSI-HOWTO,
605           available from <http://www.tldp.org/docs.html#howto>.
606
607           To compile this driver as a module, choose M here: the
608           module will be called eata_pio.
609
610 config SCSI_FUTURE_DOMAIN
611         tristate "Future Domain 16xx SCSI/AHA-2920A support"
612         depends on (ISA || PCI) && SCSI
613         ---help---
614           This is support for Future Domain's 16-bit SCSI host adapters
615           (TMC-1660/1680, TMC-1650/1670, TMC-3260, TMC-1610M/MER/MEX) and
616           other adapters based on the Future Domain chipsets (Quantum
617           ISA-200S, ISA-250MG; Adaptec AHA-2920A; and at least one IBM board).
618           It is explained in section 3.7 of the SCSI-HOWTO, available from
619           <http://www.tldp.org/docs.html#howto>.
620
621           NOTE: Newer Adaptec AHA-2920C boards use the Adaptec AIC-7850 chip
622           and should use the aic7xxx driver ("Adaptec AIC7xxx chipset SCSI
623           controller support"). This Future Domain driver works with the older
624           Adaptec AHA-2920A boards with a Future Domain chip on them.
625
626           To compile this driver as a module, choose M here: the
627           module will be called fdomain.
628
629 config SCSI_FD_MCS
630         tristate "Future Domain MCS-600/700 SCSI support"
631         depends on MCA_LEGACY && SCSI
632         ---help---
633           This is support for Future Domain MCS 600/700 MCA SCSI adapters.
634           Some PS/2 computers are equipped with IBM Fast SCSI Adapter/A which
635           is identical to the MCS 700 and hence also supported by this driver.
636           This driver also supports the Reply SB16/SCSI card (the SCSI part).
637           It supports multiple adapters in the same system.
638
639           To compile this driver as a module, choose M here: the
640           module will be called fd_mcs.
641
642 config SCSI_GDTH
643         tristate "Intel/ICP (former GDT SCSI Disk Array) RAID Controller support"
644         depends on (ISA || EISA || PCI) && SCSI && (BROKEN || !SPARC64)
645         ---help---
646           Formerly called GDT SCSI Disk Array Controller Support.
647
648           This is a driver for RAID/SCSI Disk Array Controllers (EISA/ISA/PCI) 
649           manufactured by Intel Corporation/ICP vortex GmbH. It is documented
650           in the kernel source in <file:drivers/scsi/gdth.c> and
651           <file:drivers/scsi/gdth.h.>
652
653           To compile this driver as a module, choose M here: the
654           module will be called gdth.
655
656 config SCSI_GENERIC_NCR5380
657         tristate "Generic NCR5380/53c400 SCSI PIO support"
658         depends on ISA && SCSI
659         ---help---
660           This is a driver for the old NCR 53c80 series of SCSI controllers
661           on boards using PIO. Most boards such as the Trantor T130 fit this
662           category, along with a large number of ISA 8bit controllers shipped
663           for free with SCSI scanners. If you have a PAS16, T128 or DMX3191
664           you should select the specific driver for that card rather than
665           generic 5380 support.
666
667           It is explained in section 3.8 of the SCSI-HOWTO, available from
668           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
669           of the box, you may have to change some settings in
670           <file:drivers/scsi/g_NCR5380.h>.
671
672           To compile this driver as a module, choose M here: the
673           module will be called g_NCR5380.
674
675 config SCSI_GENERIC_NCR5380_MMIO
676         tristate "Generic NCR5380/53c400 SCSI MMIO support"
677         depends on ISA && SCSI
678         ---help---
679           This is a driver for the old NCR 53c80 series of SCSI controllers
680           on boards using memory mapped I/O. 
681           It is explained in section 3.8 of the SCSI-HOWTO, available from
682           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
683           of the box, you may have to change some settings in
684           <file:drivers/scsi/g_NCR5380.h>.
685
686           To compile this driver as a module, choose M here: the
687           module will be called g_NCR5380_mmio.
688
689 config SCSI_GENERIC_NCR53C400
690         bool "Enable NCR53c400 extensions"
691         depends on SCSI_GENERIC_NCR5380
692         help
693           This enables certain optimizations for the NCR53c400 SCSI cards.
694           You might as well try it out.  Note that this driver will only probe
695           for the Trantor T130B in its default configuration; you might have
696           to pass a command line option to the kernel at boot time if it does
697           not detect your card.  See the file
698           <file:Documentation/scsi/g_NCR5380.txt> for details.
699
700 config SCSI_IBMMCA
701         tristate "IBMMCA SCSI support"
702         depends on MCA_LEGACY && SCSI
703         ---help---
704           This is support for the IBM SCSI adapter found in many of the PS/2
705           series computers.  These machines have an MCA bus, so you need to
706           answer Y to "MCA support" as well and read
707           <file:Documentation/mca.txt>.
708
709           If the adapter isn't found during boot (a common problem for models
710           56, 57, 76, and 77) you'll need to use the 'ibmmcascsi=<pun>' kernel
711           option, where <pun> is the id of the SCSI subsystem (usually 7, but
712           if that doesn't work check your reference diskette).  Owners of
713           model 95 with a LED-matrix-display can in addition activate some
714           activity info like under OS/2, but more informative, by setting
715           'ibmmcascsi=display' as an additional kernel parameter.  Try "man
716           bootparam" or see the documentation of your boot loader about how to
717           pass options to the kernel.
718
719           To compile this driver as a module, choose M here: the
720           module will be called ibmmca.
721
722 config IBMMCA_SCSI_ORDER_STANDARD
723         bool "Standard SCSI-order"
724         depends on SCSI_IBMMCA
725         ---help---
726           In the PC-world and in most modern SCSI-BIOS-setups, SCSI-hard disks
727           are assigned to the drive letters, starting with the lowest SCSI-id
728           (physical number -- pun) to be drive C:, as seen from DOS and
729           similar operating systems. When looking into papers describing the
730           ANSI-SCSI-standard, this assignment of drives appears to be wrong.
731           The SCSI-standard follows a hardware-hierarchy which says that id 7
732           has the highest priority and id 0 the lowest. Therefore, the host
733           adapters are still today everywhere placed as SCSI-id 7 by default.
734           In the SCSI-standard, the drive letters express the priority of the
735           disk. C: should be the hard disk, or a partition on it, with the
736           highest priority. This must therefore be the disk with the highest
737           SCSI-id (e.g. 6) and not the one with the lowest! IBM-BIOS kept the
738           original definition of the SCSI-standard as also industrial- and
739           process-control-machines, like VME-CPUs running under realtime-OSes
740           (e.g. LynxOS, OS9) do.
741
742           If you like to run Linux on your MCA-machine with the same
743           assignment of hard disks as seen from e.g. DOS or OS/2 on your
744           machine, which is in addition conformant to the SCSI-standard, you
745           must say Y here. This is also necessary for MCA-Linux users who want
746           to keep downward compatibility to older releases of the
747           IBM-MCA-SCSI-driver (older than driver-release 2.00 and older than
748           June 1997).
749
750           If you like to have the lowest SCSI-id assigned as drive C:, as
751           modern SCSI-BIOSes do, which does not conform to the standard, but
752           is widespread and common in the PC-world of today, you must say N
753           here. If unsure, say Y.
754
755 config IBMMCA_SCSI_DEV_RESET
756         bool "Reset SCSI-devices at boottime"
757         depends on SCSI_IBMMCA
758         ---help---
759           By default, SCSI-devices are reset when the machine is powered on.
760           However, some devices exist, like special-control-devices,
761           SCSI-CNC-machines, SCSI-printer or scanners of older type, that do
762           not reset when switched on. If you say Y here, each device connected
763           to your SCSI-bus will be issued a reset-command after it has been
764           probed, while the kernel is booting. This may cause problems with
765           more modern devices, like hard disks, which do not appreciate these
766           reset commands, and can cause your system to hang. So say Y only if
767           you know that one of your older devices needs it; N is the safe
768           answer.
769
770 config SCSI_IPS
771         tristate "IBM ServeRAID support"
772         depends on PCI && SCSI
773         ---help---
774           This is support for the IBM ServeRAID hardware RAID controllers.
775           See <http://www.developer.ibm.com/welcome/netfinity/serveraid.html>
776           for more information.  If this driver does not work correctly
777           without modification please contact the author by email at
778           ipslinux@adaptec.com.
779
780           To compile this driver as a module, choose M here: the
781           module will be called ips.
782
783 config SCSI_INITIO
784         tristate "Initio 9100U(W) support"
785         depends on PCI && SCSI && BROKEN
786         help
787           This is support for the Initio 91XXU(W) SCSI host adapter.  Please
788           read the SCSI-HOWTO, available from
789           <http://www.tldp.org/docs.html#howto>.
790
791           To compile this driver as a module, choose M here: the
792           module will be called initio.
793
794 config SCSI_INIA100
795         tristate "Initio INI-A100U2W support"
796         depends on PCI && SCSI
797         help
798           This is support for the Initio INI-A100U2W SCSI host adapter.
799           Please read the SCSI-HOWTO, available from
800           <http://www.tldp.org/docs.html#howto>.
801
802           To compile this driver as a module, choose M here: the
803           module will be called a100u2w.
804
805 config SCSI_PPA
806         tristate "IOMEGA parallel port (ppa - older drives)"
807         depends on SCSI && PARPORT
808         ---help---
809           This driver supports older versions of IOMEGA's parallel port ZIP
810           drive (a 100 MB removable media device).
811
812           Note that you can say N here if you have the SCSI version of the ZIP
813           drive: it will be supported automatically if you said Y to the
814           generic "SCSI disk support", above.
815
816           If you have the ZIP Plus drive or a more recent parallel port ZIP
817           drive (if the supplied cable with the drive is labeled "AutoDetect")
818           then you should say N here and Y to "IOMEGA parallel port (imm -
819           newer drives)", below.
820
821           For more information about this driver and how to use it you should
822           read the file <file:Documentation/scsi/ppa.txt>.  You should also read
823           the SCSI-HOWTO, which is available from
824           <http://www.tldp.org/docs.html#howto>.  If you use this driver,
825           you will still be able to use the parallel port for other tasks,
826           such as a printer; it is safe to compile both drivers into the
827           kernel.
828
829           To compile this driver as a module, choose M here: the
830           module will be called ppa.
831
832 config SCSI_IMM
833         tristate "IOMEGA parallel port (imm - newer drives)"
834         depends on SCSI && PARPORT
835         ---help---
836           This driver supports newer versions of IOMEGA's parallel port ZIP
837           drive (a 100 MB removable media device).
838
839           Note that you can say N here if you have the SCSI version of the ZIP
840           drive: it will be supported automatically if you said Y to the
841           generic "SCSI disk support", above.
842
843           If you have the ZIP Plus drive or a more recent parallel port ZIP
844           drive (if the supplied cable with the drive is labeled "AutoDetect")
845           then you should say Y here; if you have an older ZIP drive, say N
846           here and Y to "IOMEGA Parallel Port (ppa - older drives)", above.
847
848           For more information about this driver and how to use it you should
849           read the file <file:Documentation/scsi/ppa.txt>.  You should also read
850           the SCSI-HOWTO, which is available from
851           <http://www.tldp.org/docs.html#howto>.  If you use this driver,
852           you will still be able to use the parallel port for other tasks,
853           such as a printer; it is safe to compile both drivers into the
854           kernel.
855
856           To compile this driver as a module, choose M here: the
857           module will be called imm.
858
859 config SCSI_IZIP_EPP16
860         bool "ppa/imm option - Use slow (but safe) EPP-16"
861         depends on PARPORT && (SCSI_PPA || SCSI_IMM)
862         ---help---
863           EPP (Enhanced Parallel Port) is a standard for parallel ports which
864           allows them to act as expansion buses that can handle up to 64
865           peripheral devices.
866
867           Some parallel port chipsets are slower than their motherboard, and
868           so we have to control the state of the chipset's FIFO queue every
869           now and then to avoid data loss. This will be done if you say Y
870           here.
871
872           Generally, saying Y is the safe option and slows things down a bit.
873
874 config SCSI_IZIP_SLOW_CTR
875         bool "ppa/imm option - Assume slow parport control register"
876         depends on PARPORT && (SCSI_PPA || SCSI_IMM)
877         help
878           Some parallel ports are known to have excessive delays between
879           changing the parallel port control register and good data being
880           available on the parallel port data/status register. This option
881           forces a small delay (1.0 usec to be exact) after changing the
882           control register to let things settle out. Enabling this option may
883           result in a big drop in performance but some very old parallel ports
884           (found in 386 vintage machines) will not work properly.
885
886           Generally, saying N is fine.
887
888 config SCSI_NCR53C406A
889         tristate "NCR53c406a SCSI support"
890         depends on ISA && SCSI
891         help
892           This is support for the NCR53c406a SCSI host adapter.  For user
893           configurable parameters, check out <file:drivers/scsi/NCR53c406a.c>
894           in the kernel source.  Also read the SCSI-HOWTO, available from
895           <http://www.tldp.org/docs.html#howto>.
896
897           To compile this driver as a module, choose M here: the
898           module will be called NCR53c406.
899
900 config SCSI_NCR_D700
901         tristate "NCR Dual 700 MCA SCSI support"
902         depends on MCA && SCSI
903         select SCSI_SPI_ATTRS
904         help
905           This is a driver for the MicroChannel Dual 700 card produced by
906           NCR and commonly used in 345x/35xx/4100 class machines.  It always
907           tries to negotiate sync and uses tag command queueing.
908
909           Unless you have an NCR manufactured machine, the chances are that
910           you do not have this SCSI card, so say N.
911
912 config 53C700_IO_MAPPED
913         bool
914         depends on SCSI_NCR_D700
915         default y
916
917 config SCSI_LASI700
918         tristate "HP Lasi SCSI support for 53c700/710"
919         depends on GSC && SCSI
920         select SCSI_SPI_ATTRS
921         help
922           This is a driver for the SCSI controller in the Lasi chip found in
923           many PA-RISC workstations & servers.  If you do not know whether you
924           have a Lasi chip, it is safe to say "Y" here.
925
926 config 53C700_MEM_MAPPED
927         bool
928         depends on SCSI_LASI700
929         default y
930
931 config 53C700_LE_ON_BE
932         bool
933         depends on SCSI_LASI700
934         default y
935
936 config SCSI_SYM53C8XX_2
937         tristate "SYM53C8XX Version 2 SCSI support"
938         depends on PCI && SCSI
939         select SCSI_SPI_ATTRS
940         ---help---
941           This driver supports the whole NCR53C8XX/SYM53C8XX family of
942           PCI-SCSI controllers.  It also supports the subset of LSI53C10XX
943           Ultra-160 controllers that are based on the SYM53C8XX SCRIPTS
944           language.  It does not support LSI53C10XX Ultra-320 PCI-X SCSI
945           controllers; you need to use the Fusion MPT driver for that.
946
947           Please read <file:Documentation/scsi/sym53c8xx_2.txt> for more
948           information.
949
950 config SCSI_SYM53C8XX_DMA_ADDRESSING_MODE
951         int "DMA addressing mode"
952         depends on SCSI_SYM53C8XX_2
953         default "1"
954         ---help---
955           This option only applies to PCI-SCSI chips that are PCI DAC
956           capable (875A, 895A, 896, 1010-33, 1010-66, 1000).
957
958           When set to 0, the driver will program the chip to only perform
959           32-bit DMA.  When set to 1, the chip will be able to perform DMA
960           to addresses up to 1TB.  When set to 2, the driver supports the
961           full 64-bit DMA address range, but can only address 16 segments
962           of 4 GB each.  This limits the total addressable range to 64 GB.
963
964           Most machines with less than 4GB of memory should use a setting
965           of 0 for best performance.  If your machine has 4GB of memory
966           or more, you should set this option to 1 (the default).
967
968           The still experimental value 2 (64 bit DMA addressing with 16
969           x 4GB segments limitation) can be used on systems that require
970           PCI address bits past bit 39 to be set for the addressing of
971           memory using PCI DAC cycles.
972
973 config SCSI_SYM53C8XX_DEFAULT_TAGS
974         int "default tagged command queue depth"
975         depends on SCSI_SYM53C8XX_2
976         default "16"
977         help
978           This is the default value of the command queue depth the
979           driver will announce to the generic SCSI layer for devices
980           that support tagged command queueing. This value can be changed
981           from the boot command line.  This is a soft limit that cannot
982           exceed CONFIG_SCSI_SYM53C8XX_MAX_TAGS.
983
984 config SCSI_SYM53C8XX_MAX_TAGS
985         int "maximum number of queued commands"
986         depends on SCSI_SYM53C8XX_2
987         default "64"
988         help
989           This option allows you to specify the maximum number of commands
990           that can be queued to any device, when tagged command queuing is
991           possible. The driver supports up to 256 queued commands per device.
992           This value is used as a compiled-in hard limit.
993
994 config SCSI_SYM53C8XX_IOMAPPED
995         bool "use port IO"
996         depends on SCSI_SYM53C8XX_2
997         help
998           If you say Y here, the driver will use port IO to access
999           the card.  This is significantly slower then using memory
1000           mapped IO.  Most people should answer N.
1001
1002 config SCSI_IPR
1003         tristate "IBM Power Linux RAID adapter support"
1004         depends on PCI && SCSI
1005         select FW_LOADER
1006         ---help---
1007           This driver supports the IBM Power Linux family RAID adapters.
1008           This includes IBM pSeries 5712, 5703, 5709, and 570A, as well
1009           as IBM iSeries 5702, 5703, 5709, and 570A.
1010
1011 config SCSI_IPR_TRACE
1012         bool "enable driver internal trace"
1013         depends on SCSI_IPR
1014         help
1015           If you say Y here, the driver will trace all commands issued
1016           to the adapter. Performance impact is minimal. Trace can be
1017           dumped using /sys/bus/class/scsi_host/hostXX/trace.
1018
1019 config SCSI_IPR_DUMP
1020         bool "enable adapter dump support"
1021         depends on SCSI_IPR
1022         help
1023           If you say Y here, the driver will support adapter crash dump.
1024           If you enable this support, the iprdump daemon can be used
1025           to capture adapter failure analysis information.
1026
1027 config SCSI_ZALON
1028         tristate "Zalon SCSI support"
1029         depends on GSC && SCSI
1030         help
1031           The Zalon is a GSC/HSC bus interface chip that sits between the
1032           PA-RISC processor and the NCR 53c720 SCSI controller on C100,
1033           C110, J200, J210 and some D, K & R-class machines.  It's also
1034           used on the add-in Bluefish, Barracuda & Shrike SCSI cards.
1035           Say Y here if you have one of these machines or cards.
1036
1037 config SCSI_NCR_Q720
1038         tristate "NCR Quad 720 MCA SCSI support"
1039         depends on MCA && SCSI
1040         help
1041           This is a driver for the MicroChannel Quad 720 card produced by
1042           NCR and commonly used in 345x/35xx/4100 class machines.  It always
1043           tries to negotiate sync and uses tag command queueing.
1044
1045           Unless you have an NCR manufactured machine, the chances are that
1046           you do not have this SCSI card, so say N.
1047
1048 config SCSI_NCR53C8XX_DEFAULT_TAGS
1049         int "  default tagged command queue depth"
1050         depends on SCSI_ZALON || SCSI_NCR_Q720
1051         default "8"
1052         ---help---
1053           "Tagged command queuing" is a feature of SCSI-2 which improves
1054           performance: the host adapter can send several SCSI commands to a
1055           device's queue even if previous commands haven't finished yet.
1056           Because the device is intelligent, it can optimize its operations
1057           (like head positioning) based on its own request queue. Some SCSI
1058           devices don't implement this properly; if you want to disable this
1059           feature, enter 0 or 1 here (it doesn't matter which).
1060
1061           The default value is 8 and should be supported by most hard disks.
1062           This value can be overridden from the boot command line using the
1063           'tags' option as follows (example):
1064           'ncr53c8xx=tags:4/t2t3q16/t0u2q10' will set default queue depth to
1065           4, set queue depth to 16 for target 2 and target 3 on controller 0
1066           and set queue depth to 10 for target 0 / lun 2 on controller 1.
1067
1068           The normal answer therefore is to go with the default 8 and to use
1069           a boot command line option for devices that need to use a different
1070           command queue depth.
1071
1072           There is no safe option other than using good SCSI devices.
1073
1074 config SCSI_NCR53C8XX_MAX_TAGS
1075         int "  maximum number of queued commands"
1076         depends on SCSI_ZALON || SCSI_NCR_Q720
1077         default "32"
1078         ---help---
1079           This option allows you to specify the maximum number of commands
1080           that can be queued to any device, when tagged command queuing is
1081           possible. The default value is 32. Minimum is 2, maximum is 64.
1082           Modern hard disks are able to support 64 tags and even more, but
1083           do not seem to be faster when more than 32 tags are being used.
1084
1085           So, the normal answer here is to go with the default value 32 unless
1086           you are using very large hard disks with large cache (>= 1 MB) that
1087           are able to take advantage of more than 32 tagged commands.
1088
1089           There is no safe option and the default answer is recommended.
1090
1091 config SCSI_NCR53C8XX_SYNC
1092         int "  synchronous transfers frequency in MHz"
1093         depends on SCSI_ZALON || SCSI_NCR_Q720
1094         default "20"
1095         ---help---
1096           The SCSI Parallel Interface-2 Standard defines 5 classes of transfer
1097           rates: FAST-5, FAST-10, FAST-20, FAST-40 and FAST-80.  The numbers
1098           are respectively the maximum data transfer rates in mega-transfers
1099           per second for each class.  For example, a FAST-20 Wide 16 device is
1100           able to transfer data at 20 million 16 bit packets per second for a
1101           total rate of 40 MB/s.
1102
1103           You may specify 0 if you want to only use asynchronous data
1104           transfers. This is the safest and slowest option. Otherwise, specify
1105           a value between 5 and 80, depending on the capability of your SCSI
1106           controller.  The higher the number, the faster the data transfer.
1107           Note that 80 should normally be ok since the driver decreases the
1108           value automatically according to the controller's capabilities.
1109
1110           Your answer to this question is ignored for controllers with NVRAM,
1111           since the driver will get this information from the user set-up.  It
1112           also can be overridden using a boot setup option, as follows
1113           (example): 'ncr53c8xx=sync:12' will allow the driver to negotiate
1114           for FAST-20 synchronous data transfer (20 mega-transfers per
1115           second).
1116
1117           The normal answer therefore is not to go with the default but to
1118           select the maximum value 80 allowing the driver to use the maximum
1119           value supported by each controller. If this causes problems with
1120           your SCSI devices, you should come back and decrease the value.
1121
1122           There is no safe option other than using good cabling, right
1123           terminations and SCSI conformant devices.
1124
1125 config SCSI_NCR53C8XX_PROFILE
1126         bool "  enable profiling"
1127         depends on SCSI_ZALON || SCSI_NCR_Q720
1128         help
1129           This option allows you to enable profiling information gathering.
1130           These statistics are not very accurate due to the low frequency
1131           of the kernel clock (100 Hz on i386) and have performance impact
1132           on systems that use very fast devices.
1133
1134           The normal answer therefore is N.
1135
1136 config SCSI_NCR53C8XX_NO_DISCONNECT
1137         bool "  not allow targets to disconnect"
1138         depends on (SCSI_ZALON || SCSI_NCR_Q720) && SCSI_NCR53C8XX_DEFAULT_TAGS=0
1139         help
1140           This option is only provided for safety if you suspect some SCSI
1141           device of yours to not support properly the target-disconnect
1142           feature. In that case, you would say Y here. In general however, to
1143           not allow targets to disconnect is not reasonable if there is more
1144           than 1 device on a SCSI bus. The normal answer therefore is N.
1145
1146 config SCSI_MCA_53C9X
1147         tristate "NCR MCA 53C9x SCSI support"
1148         depends on MCA_LEGACY && SCSI && BROKEN_ON_SMP
1149         help
1150           Some MicroChannel machines, notably the NCR 35xx line, use a SCSI
1151           controller based on the NCR 53C94.  This driver will allow use of
1152           the controller on the 3550, and very possibly others.
1153
1154           To compile this driver as a module, choose M here: the
1155           module will be called mca_53c9x.
1156
1157 config SCSI_PAS16
1158         tristate "PAS16 SCSI support"
1159         depends on ISA && SCSI
1160         ---help---
1161           This is support for a SCSI host adapter.  It is explained in section
1162           3.10 of the SCSI-HOWTO, available from
1163           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
1164           of the box, you may have to change some settings in
1165           <file:drivers/scsi/pas16.h>.
1166
1167           To compile this driver as a module, choose M here: the
1168           module will be called pas16.
1169
1170 config SCSI_PCI2000
1171         tristate "PCI2000 support"
1172         depends on PCI && SCSI && BROKEN
1173         help
1174           This is support for the PCI2000I EIDE interface card which acts as a
1175           SCSI host adapter.  Please read the SCSI-HOWTO, available from
1176           <http://www.tldp.org/docs.html#howto>.
1177
1178           To compile this driver as a module, choose M here: the
1179           module will be called pci2000.
1180
1181 config SCSI_PCI2220I
1182         tristate "PCI2220i support"
1183         depends on PCI && SCSI && BROKEN
1184         help
1185           This is support for the PCI2220i EIDE interface card which acts as a
1186           SCSI host adapter.  Please read the SCSI-HOWTO, available from
1187           <http://www.tldp.org/docs.html#howto>.
1188
1189           To compile this driver as a module, choose M here: the
1190           module will be called pci2220i.
1191
1192 config SCSI_PSI240I
1193         tristate "PSI240i support"
1194         depends on ISA && SCSI
1195         help
1196           This is support for the PSI240i EIDE interface card which acts as a
1197           SCSI host adapter.  Please read the SCSI-HOWTO, available from
1198           <http://www.tldp.org/docs.html#howto>.
1199
1200           To compile this driver as a module, choose M here: the
1201           module will be called psi240i.
1202
1203 config SCSI_QLOGIC_FAS
1204         tristate "Qlogic FAS SCSI support"
1205         depends on ISA && SCSI
1206         ---help---
1207           This is a driver for the ISA, VLB, and PCMCIA versions of the Qlogic
1208           FastSCSI! cards as well as any other card based on the FASXX chip
1209           (including the Control Concepts SCSI/IDE/SIO/PIO/FDC cards).
1210
1211           This driver does NOT support the PCI versions of these cards. The
1212           PCI versions are supported by the Qlogic ISP driver ("Qlogic ISP
1213           SCSI support"), below.
1214
1215           Information about this driver is contained in
1216           <file:Documentation/scsi/qlogicfas.txt>.  You should also read the
1217           SCSI-HOWTO, available from
1218           <http://www.tldp.org/docs.html#howto>.
1219
1220           To compile this driver as a module, choose M here: the
1221           module will be called qlogicfas.
1222
1223 config SCSI_QLOGIC_ISP
1224         tristate "Qlogic ISP SCSI support"
1225         depends on PCI && SCSI
1226         ---help---
1227           This driver works for all QLogic PCI SCSI host adapters (IQ-PCI,
1228           IQ-PCI-10, IQ_PCI-D) except for the PCI-basic card.  (This latter
1229           card is supported by the "AM53/79C974 PCI SCSI" driver.)
1230
1231           If you say Y here, make sure to choose "BIOS" at the question "PCI
1232           access mode".
1233
1234           Please read the file <file:Documentation/scsi/qlogicisp.txt>.  You
1235           should also read the SCSI-HOWTO, available from
1236           <http://www.tldp.org/docs.html#howto>.
1237
1238           To compile this driver as a module, choose M here: the
1239           module will be called qlogicisp.
1240
1241 config SCSI_QLOGIC_FC
1242         tristate "Qlogic ISP FC SCSI support"
1243         depends on PCI && SCSI
1244         help
1245           This is a driver for the QLogic ISP2100 SCSI-FCP host adapter.
1246
1247           To compile this driver as a module, choose M here: the
1248           module will be called qlogicfc.
1249
1250 config SCSI_QLOGIC_FC_FIRMWARE
1251         bool "Include loadable firmware in driver"
1252         depends on SCSI_QLOGIC_FC
1253         help
1254           Say Y to include ISP2X00 Fabric Initiator/Target Firmware, with
1255           expanded LUN addressing and FcTape (FCP-2) support, in the
1256           qlogicfc driver. This is required on some platforms.
1257
1258 config SCSI_QLOGIC_1280
1259         tristate "Qlogic QLA 1280 SCSI support"
1260         depends on PCI && SCSI
1261         help
1262           Say Y if you have a QLogic ISP1x80/1x160 SCSI host adapter.
1263
1264           To compile this driver as a module, choose M here: the
1265           module will be called qla1280.
1266
1267 config SCSI_QLOGICPTI
1268         tristate "PTI Qlogic, ISP Driver"
1269         depends on SBUS && SCSI
1270         help
1271           This driver supports SBUS SCSI controllers from PTI or QLogic. These
1272           controllers are known under Solaris as qpti and in the openprom as
1273           PTI,ptisp or QLGC,isp. Note that PCI QLogic SCSI controllers are
1274           driven by a different driver.
1275
1276           To compile this driver as a module, choose M here: the
1277           module will be called qlogicpti.
1278
1279 source "drivers/scsi/qla2xxx/Kconfig"
1280
1281 config SCSI_SEAGATE
1282         tristate "Seagate ST-02 and Future Domain TMC-8xx SCSI support"
1283         depends on X86 && ISA && SCSI && BROKEN
1284         ---help---
1285           These are 8-bit SCSI controllers; the ST-01 is also supported by
1286           this driver.  It is explained in section 3.9 of the SCSI-HOWTO,
1287           available from <http://www.tldp.org/docs.html#howto>.  If it
1288           doesn't work out of the box, you may have to change some settings in
1289           <file:drivers/scsi/seagate.h>.
1290
1291           To compile this driver as a module, choose M here: the
1292           module will be called seagate.
1293
1294 # definitely looks not 64bit safe:
1295 config SCSI_SIM710
1296         tristate "Simple 53c710 SCSI support (Compaq, NCR machines)"
1297         depends on (EISA || MCA) && SCSI
1298         select SCSI_SPI_ATTRS
1299         ---help---
1300           This driver for NCR53c710 based SCSI host adapters.
1301
1302           It currently supports Compaq EISA cards and NCR MCA cards
1303
1304 config 53C700_IO_MAPPED
1305         bool
1306         depends on SCSI_SIM710
1307         default y
1308
1309 config SCSI_SYM53C416
1310         tristate "Symbios 53c416 SCSI support"
1311         depends on ISA && SCSI
1312         ---help---
1313           This is support for the sym53c416 SCSI host adapter, the SCSI
1314           adapter that comes with some HP scanners. This driver requires that
1315           the sym53c416 is configured first using some sort of PnP
1316           configuration program (e.g. isapnp) or by a PnP aware BIOS. If you
1317           are using isapnp then you need to compile this driver as a module
1318           and then load it using insmod after isapnp has run. The parameters
1319           of the configured card(s) should be passed to the driver. The format
1320           is:
1321
1322           insmod sym53c416 sym53c416=<base>,<irq> [sym53c416_1=<base>,<irq>]
1323
1324           To compile this driver as a module, choose M here: the
1325           module will be called sym53c416.
1326
1327 config SCSI_DC395x
1328         tristate "Tekram DC395(U/UW/F) and DC315(U) SCSI support (EXPERIMENTAL)"
1329         depends on PCI && SCSI && EXPERIMENTAL
1330         ---help---
1331           This driver supports PCI SCSI host adapters based on the ASIC
1332           TRM-S1040 chip, e.g Tekram DC395(U/UW/F) and DC315(U) variants.
1333
1334           This driver works, but is still in experimental status. So better
1335           have a bootable disk and a backup in case of emergency.
1336
1337           Documentation can be found in <file:Documentation/scsi/dc395x.txt>.
1338
1339           To compile this driver as a module, choose M here: the
1340           module will be called dc395x.
1341
1342 config SCSI_DC390T
1343         tristate "Tekram DC390(T) and Am53/79C974 SCSI support"
1344         depends on PCI && SCSI
1345         ---help---
1346           This driver supports PCI SCSI host adapters based on the Am53C974A
1347           chip, e.g. Tekram DC390(T), DawiControl 2974 and some onboard
1348           PCscsi/PCnet (Am53/79C974) solutions.
1349
1350           Documentation can be found in <file:Documentation/scsi/tmscsim.txt>.
1351
1352           Note that this driver does NOT support Tekram DC390W/U/F, which are
1353           based on NCR/Symbios chips. Use "NCR53C8XX SCSI support" for those.
1354
1355           To compile this driver as a module, choose M here: the
1356           module will be called tmscsim.
1357
1358 config SCSI_T128
1359         tristate "Trantor T128/T128F/T228 SCSI support"
1360         depends on ISA && SCSI
1361         ---help---
1362           This is support for a SCSI host adapter. It is explained in section
1363           3.11 of the SCSI-HOWTO, available from
1364           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
1365           of the box, you may have to change some settings in
1366           <file:drivers/scsi/t128.h>.  Note that Trantor was purchased by
1367           Adaptec, and some former Trantor products are being sold under the
1368           Adaptec name.
1369
1370           To compile this driver as a module, choose M here: the
1371           module will be called t128.
1372
1373 config SCSI_U14_34F
1374         tristate "UltraStor 14F/34F support"
1375         depends on ISA && SCSI
1376         ---help---
1377           This is support for the UltraStor 14F and 34F SCSI-2 host adapters.
1378           The source at <file:drivers/scsi/u14-34f.c> contains some
1379           information about this hardware.  If the driver doesn't work out of
1380           the box, you may have to change some settings in
1381           <file: drivers/scsi/u14-34f.c>.  Read the SCSI-HOWTO, available from
1382           <http://www.tldp.org/docs.html#howto>.  Note that there is also
1383           another driver for the same hardware: "UltraStor SCSI support",
1384           below.  You should say Y to both only if you want 24F support as
1385           well.
1386
1387           To compile this driver as a module, choose M here: the
1388           module will be called u14-34f.
1389
1390 config SCSI_U14_34F_TAGGED_QUEUE
1391         bool "enable tagged command queueing"
1392         depends on SCSI_U14_34F
1393         help
1394           This is a feature of SCSI-2 which improves performance: the host
1395           adapter can send several SCSI commands to a device's queue even if
1396           previous commands haven't finished yet.
1397           This is equivalent to the "u14-34f=tc:y" boot option.
1398
1399 config SCSI_U14_34F_LINKED_COMMANDS
1400         bool "enable elevator sorting"
1401         depends on SCSI_U14_34F
1402         help
1403           This option enables elevator sorting for all probed SCSI disks and
1404           CD-ROMs. It definitely reduces the average seek distance when doing
1405           random seeks, but this does not necessarily result in a noticeable
1406           performance improvement: your mileage may vary...
1407           This is equivalent to the "u14-34f=lc:y" boot option.
1408
1409 config SCSI_U14_34F_MAX_TAGS
1410         int "maximum number of queued commands"
1411         depends on SCSI_U14_34F
1412         default "8"
1413         help
1414           This specifies how many SCSI commands can be maximally queued for
1415           each probed SCSI device. You should reduce the default value of 8
1416           only if you have disks with buggy or limited tagged command support.
1417           Minimum is 2 and maximum is 14. This value is also the window size
1418           used by the elevator sorting option above. The effective value used
1419           by the driver for each probed SCSI device is reported at boot time.
1420           This is equivalent to the "u14-34f=mq:8" boot option.
1421
1422 config SCSI_ULTRASTOR
1423         tristate "UltraStor SCSI support"
1424         depends on X86 && ISA && SCSI
1425         ---help---
1426           This is support for the UltraStor 14F, 24F and 34F SCSI-2 host
1427           adapter family.  This driver is explained in section 3.12 of the
1428           SCSI-HOWTO, available from
1429           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
1430           of the box, you may have to change some settings in
1431           <file:drivers/scsi/ultrastor.h>.
1432
1433           Note that there is also another driver for the same hardware:
1434           "UltraStor 14F/34F support", above.
1435
1436           To compile this driver as a module, choose M here: the
1437           module will be called ultrastor.
1438
1439 config SCSI_NSP32
1440         tristate "Workbit NinjaSCSI-32Bi/UDE support"
1441         depends on PCI && SCSI && !64BIT
1442         help
1443           This is support for the Workbit NinjaSCSI-32Bi/UDE PCI/Cardbus
1444           SCSI host adapter. Please read the SCSI-HOWTO, available from
1445           <http://www.tldp.org/docs.html#howto>.
1446
1447           To compile this driver as a module, choose M here: the
1448           module will be called nsp32.
1449
1450 config SCSI_DEBUG
1451         tristate "SCSI debugging host simulator"
1452         depends on SCSI
1453         help
1454           This is a host adapter simulator that can simulate multiple hosts
1455           each with multiple dummy SCSI devices (disks). It defaults to one
1456           host adapter with one dummy SCSI disk. Each dummy disk uses kernel
1457           RAM as storage (i.e. it is a ramdisk). To save space when multiple
1458           dummy disks are simulated, they share the same kernel RAM for 
1459           their storage. See http://www.torque.net/sg/sdebug.html for more
1460           information. This driver is primarily of use to those testing the
1461           SCSI and block subsystems. If unsure, say N.
1462
1463 config SCSI_MESH
1464         tristate "MESH (Power Mac internal SCSI) support"
1465         depends on PPC_PMAC && SCSI
1466         help
1467           Many Power Macintoshes and clones have a MESH (Macintosh Enhanced
1468           SCSI Hardware) SCSI bus adaptor (the 7200 doesn't, but all of the
1469           other Power Macintoshes do). Say Y to include support for this SCSI
1470           adaptor.
1471
1472           To compile this driver as a module, choose M here: the
1473           module will be called mesh.
1474
1475 config SCSI_MESH_SYNC_RATE
1476         int "maximum synchronous transfer rate (MB/s) (0 = async)"
1477         depends on SCSI_MESH
1478         default "5"
1479         help
1480           On Power Macintoshes (and clones) where the MESH SCSI bus adaptor
1481           drives a bus which is entirely internal to the machine (such as the
1482           7500, 7600, 8500, etc.), the MESH is capable of synchronous
1483           operation at up to 10 MB/s. On machines where the SCSI bus
1484           controlled by the MESH can have external devices connected, it is
1485           usually rated at 5 MB/s. 5 is a safe value here unless you know the
1486           MESH SCSI bus is internal only; in that case you can say 10. Say 0
1487           to disable synchronous operation.
1488
1489 config SCSI_MESH_RESET_DELAY_MS
1490         int "initial bus reset delay (ms) (0 = no reset)"
1491         depends on SCSI_MESH
1492         default "4000"
1493
1494 config SCSI_MAC53C94
1495         tristate "53C94 (Power Mac external SCSI) support"
1496         depends on PPC_PMAC && SCSI
1497         help
1498           On Power Macintoshes (and clones) with two SCSI buses, the external
1499           SCSI bus is usually controlled by a 53C94 SCSI bus adaptor. Older
1500           machines which only have one SCSI bus, such as the 7200, also use
1501           the 53C94. Say Y to include support for the 53C94.
1502
1503           To compile this driver as a module, choose M here: the
1504           module will be called mac53c94.
1505
1506 source "drivers/scsi/arm/Kconfig"
1507
1508 config JAZZ_ESP
1509         bool "MIPS JAZZ FAS216 SCSI support"
1510         depends on MIPS_JAZZ && SCSI
1511         help
1512           This is the driver for the onboard SCSI host adapter of MIPS Magnum
1513           4000, Acer PICA, Olivetti M700-10 and a few other identical OEM
1514           systems.
1515
1516 config A3000_SCSI
1517         tristate "A3000 WD33C93A support"
1518         depends on AMIGA && SCSI
1519         help
1520           If you have an Amiga 3000 and have SCSI devices connected to the
1521           built-in SCSI controller, say Y. Otherwise, say N.
1522
1523           To compile this driver as a module, choose M here: the
1524           module will be called wd33c93.
1525
1526 config A2091_SCSI
1527         tristate "A2091/A590 WD33C93A support"
1528         depends on ZORRO && SCSI
1529         help
1530           If you have a Commodore A2091 SCSI controller, say Y. Otherwise,
1531           say N.
1532
1533           To compile this driver as a module, choose M here: the
1534           module will be called wd33c93.
1535
1536 config GVP11_SCSI
1537         tristate "GVP Series II WD33C93A support"
1538         depends on ZORRO && SCSI
1539         ---help---
1540           If you have a Great Valley Products Series II SCSI controller,
1541           answer Y. Also say Y if you have a later model of GVP SCSI
1542           controller (such as the GVP A4008 or a Combo board). Otherwise,
1543           answer N. This driver does NOT work for the T-Rex series of
1544           accelerators from TekMagic and GVP-M.
1545
1546           To compile this driver as a module, choose M here: the
1547           module will be called gvp11.
1548
1549 config CYBERSTORM_SCSI
1550         tristate "CyberStorm SCSI support"
1551         depends on ZORRO && SCSI
1552         help
1553           If you have an Amiga with an original (MkI) Phase5 Cyberstorm
1554           accelerator board and the optional Cyberstorm SCSI controller,
1555           answer Y. Otherwise, say N.
1556
1557 config CYBERSTORMII_SCSI
1558         tristate "CyberStorm Mk II SCSI support"
1559         depends on ZORRO && SCSI
1560         help
1561           If you have an Amiga with a Phase5 Cyberstorm MkII accelerator board
1562           and the optional Cyberstorm SCSI controller, say Y. Otherwise,
1563           answer N.
1564
1565 config BLZ2060_SCSI
1566         tristate "Blizzard 2060 SCSI support"
1567         depends on ZORRO && SCSI
1568         help
1569           If you have an Amiga with a Phase5 Blizzard 2060 accelerator board
1570           and want to use the onboard SCSI controller, say Y. Otherwise,
1571           answer N.
1572
1573 config BLZ1230_SCSI
1574         tristate "Blizzard 1230IV/1260 SCSI support"
1575         depends on ZORRO && SCSI
1576         help
1577           If you have an Amiga 1200 with a Phase5 Blizzard 1230IV or Blizzard
1578           1260 accelerator, and the optional SCSI module, say Y. Otherwise,
1579           say N.
1580
1581 config FASTLANE_SCSI
1582         tristate "Fastlane SCSI support"
1583         depends on ZORRO && SCSI
1584         help
1585           If you have the Phase5 Fastlane Z3 SCSI controller, or plan to use
1586           one in the near future, say Y to this question. Otherwise, say N.
1587
1588 config SCSI_AMIGA7XX
1589         bool "Amiga NCR53c710 SCSI support (EXPERIMENTAL)"
1590         depends on AMIGA && SCSI && EXPERIMENTAL && BROKEN
1591         help
1592           Support for various NCR53c710-based SCSI controllers on the Amiga.
1593           This includes:
1594             - the builtin SCSI controller on the Amiga 4000T,
1595             - the Amiga 4091 Zorro III SCSI-2 controller,
1596             - the MacroSystem Development's WarpEngine Amiga SCSI-2 controller
1597               (info at
1598               <http://www.lysator.liu.se/amiga/ar/guide/ar310.guide?FEATURE5>),
1599             - the SCSI controller on the Phase5 Blizzard PowerUP 603e+
1600               accelerator card for the Amiga 1200,
1601             - the SCSI controller on the GVP Turbo 040/060 accelerator.
1602           Note that all of the above SCSI controllers, except for the builtin
1603           SCSI controller on the Amiga 4000T, reside on the Zorro expansion
1604           bus, so you also have to enable Zorro bus support if you want to use
1605           them.
1606
1607 config OKTAGON_SCSI
1608         tristate "BSC Oktagon SCSI support (EXPERIMENTAL)"
1609         depends on ZORRO && SCSI && EXPERIMENTAL
1610         help
1611           If you have the BSC Oktagon SCSI disk controller for the Amiga, say
1612           Y to this question.  If you're in doubt about whether you have one,
1613           see the picture at
1614           <http://amiga.resource.cx/exp/search.pl?product=oktagon>.
1615
1616 config ATARI_SCSI
1617         tristate "Atari native SCSI support"
1618         depends on ATARI && SCSI && BROKEN
1619         ---help---
1620           If you have an Atari with built-in NCR5380 SCSI controller (TT,
1621           Falcon, ...) say Y to get it supported. Of course also, if you have
1622           a compatible SCSI controller (e.g. for Medusa).
1623
1624           To compile this driver as a module, choose M here: the
1625           module will be called atari_scsi.
1626
1627           This driver supports both styles of NCR integration into the
1628           system: the TT style (separate DMA), and the Falcon style (via
1629           ST-DMA, replacing ACSI).  It does NOT support other schemes, like
1630           in the Hades (without DMA).
1631
1632 config ATARI_SCSI_TOSHIBA_DELAY
1633         bool "Long delays for Toshiba CD-ROMs"
1634         depends on ATARI_SCSI
1635         help
1636           This option increases the delay after a SCSI arbitration to
1637           accommodate some flaky Toshiba CD-ROM drives. Say Y if you intend to
1638           use a Toshiba CD-ROM drive; otherwise, the option is not needed and
1639           would impact performance a bit, so say N.
1640
1641 config ATARI_SCSI_RESET_BOOT
1642         bool "Reset SCSI-devices at boottime"
1643         depends on ATARI_SCSI
1644         help
1645           Reset the devices on your Atari whenever it boots.  This makes the
1646           boot process fractionally longer but may assist recovery from errors
1647           that leave the devices with SCSI operations partway completed.
1648
1649 config TT_DMA_EMUL
1650         bool "Hades SCSI DMA emulator"
1651         depends on ATARI_SCSI && HADES
1652         help
1653           This option enables code which emulates the TT SCSI DMA chip on the
1654           Hades. This increases the SCSI transfer rates at least ten times
1655           compared to PIO transfers.
1656
1657 config MAC_SCSI
1658         bool "Macintosh NCR5380 SCSI"
1659         depends on MAC && SCSI
1660         help
1661           This is the NCR 5380 SCSI controller included on most of the 68030
1662           based Macintoshes.  If you have one of these say Y and read the
1663           SCSI-HOWTO, available from
1664           <http://www.tldp.org/docs.html#howto>.
1665
1666 config SCSI_MAC_ESP
1667         tristate "Macintosh NCR53c9[46] SCSI"
1668         depends on MAC && SCSI
1669         help
1670           This is the NCR 53c9x SCSI controller found on most of the 68040
1671           based Macintoshes.  If you have one of these say Y and read the
1672           SCSI-HOWTO, available from
1673           <http://www.tldp.org/docs.html#howto>.
1674
1675           To compile this driver as a module, choose M here: the
1676           module will be called mac_esp.
1677
1678 config MVME147_SCSI
1679         bool "WD33C93 SCSI driver for MVME147"
1680         depends on MVME147 && SCSI
1681         help
1682           Support for the on-board SCSI controller on the Motorola MVME147
1683           single-board computer.
1684
1685 config MVME16x_SCSI
1686         bool "NCR53C710 SCSI driver for MVME16x"
1687         depends on MVME16x && SCSI && BROKEN
1688         help
1689           The Motorola MVME162, 166, 167, 172 and 177 boards use the NCR53C710
1690           SCSI controller chip.  Almost everyone using one of these boards
1691           will want to say Y to this question.
1692
1693 config BVME6000_SCSI
1694         bool "NCR53C710 SCSI driver for BVME6000"
1695         depends on BVME6000 && SCSI && BROKEN
1696         help
1697           The BVME4000 and BVME6000 boards from BVM Ltd use the NCR53C710
1698           SCSI controller chip.  Almost everyone using one of these boards
1699           will want to say Y to this question.
1700
1701 config SCSI_NCR53C7xx_FAST
1702         bool "allow FAST-SCSI [10MHz]"
1703         depends on SCSI_AMIGA7XX || MVME16x_SCSI || BVME6000_SCSI
1704         help
1705           This will enable 10MHz FAST-SCSI transfers with your host
1706           adapter. Some systems have problems with that speed, so it's safest
1707           to say N here.
1708
1709 config SUN3_SCSI
1710         tristate "Sun3 NCR5380 SCSI"
1711         depends on SUN3 && SCSI
1712         help
1713           This option will enable support for the OBIO (onboard io) NCR5380
1714           SCSI controller found in the Sun 3/50 and 3/60, as well as for
1715           "Sun3" type VME scsi controllers also based on the NCR5380.
1716           General Linux information on the Sun 3 series (now discontinued)
1717           is at <http://www.angelfire.com/ca2/tech68k/sun3.html>.
1718
1719 config SUN3X_ESP
1720         bool "Sun3x ESP SCSI"
1721         depends on SUN3X && SCSI
1722         help
1723           The ESP was an on-board SCSI controller used on Sun 3/80
1724           machines.  Say Y here to compile in support for it.
1725
1726 config SCSI_SUNESP
1727         tristate "Sparc ESP Scsi Driver"
1728         depends on SBUS && SCSI
1729         help
1730           This is the driver for the Sun ESP SCSI host adapter. The ESP
1731           chipset is present in most SPARC SBUS-based computers.
1732
1733           To compile this driver as a module, choose M here: the
1734           module will be called esp.
1735
1736 #      bool 'Cyberstorm Mk III SCSI support (EXPERIMENTAL)' CONFIG_CYBERSTORMIII_SCSI
1737
1738 config ZFCP
1739         tristate "FCP host bus adapter driver for IBM eServer zSeries"
1740         depends on ARCH_S390 && SCSI
1741         select SCSI_FC_ATTRS
1742         help
1743           If you want to access SCSI devices attached to your IBM eServer
1744           zSeries by means of Fibre Channel interfaces say Y.
1745           For details please refer to the documentation provided by IBM at
1746           <http://oss.software.ibm.com/developerworks/opensource/linux390>
1747
1748           This driver is also available as a module. This module will be
1749           called zfcp. If you want to compile it as a module, say M here
1750           and read Documentation/modules.txt.
1751
1752 endmenu
1753
1754 source "drivers/scsi/pcmcia/Kconfig"
1755
1756 endmenu