Merge to Fedora kernel-2.6.18-1.2224_FC5 patched with stable patch-2.6.18.1-vs2.0...
[linux-2.6.git] / drivers / scsi / Kconfig
1 menu "SCSI device support"
2
3 config RAID_ATTRS
4         tristate "RAID Transport Class"
5         default n
6         ---help---
7           Provides RAID
8
9 config SCSI
10         tristate "SCSI device support"
11         ---help---
12           If you want to use a SCSI hard disk, SCSI tape drive, SCSI CD-ROM or
13           any other SCSI device under Linux, say Y and make sure that you know
14           the name of your SCSI host adapter (the card inside your computer
15           that "speaks" the SCSI protocol, also called SCSI controller),
16           because you will be asked for it.
17
18           You also need to say Y here if you have a device which speaks
19           the SCSI protocol.  Examples of this include the parallel port
20           version of the IOMEGA ZIP drive, USB storage devices, Fibre
21           Channel, FireWire storage and the IDE-SCSI emulation driver.
22
23           To compile this driver as a module, choose M here and read
24           <file:Documentation/scsi/scsi.txt>.
25           The module will be called scsi_mod.
26
27           However, do not compile this as a module if your root file system
28           (the one containing the directory /) is located on a SCSI device.
29
30 config SCSI_PROC_FS
31         bool "legacy /proc/scsi/ support"
32         depends on SCSI && PROC_FS
33         default y
34         ---help---
35           This option enables support for the various files in
36           /proc/scsi.  In Linux 2.6 this has been superceeded by
37           files in sysfs but many legacy applications rely on this.
38
39           If unusure say Y.
40
41 comment "SCSI support type (disk, tape, CD-ROM)"
42         depends on SCSI
43
44 config BLK_DEV_SD
45         tristate "SCSI disk support"
46         depends on SCSI
47         ---help---
48           If you want to use SCSI hard disks, Fibre Channel disks,
49           USB storage or the SCSI or parallel port version of
50           the IOMEGA ZIP drive, say Y and read the SCSI-HOWTO,
51           the Disk-HOWTO and the Multi-Disk-HOWTO, available from
52           <http://www.tldp.org/docs.html#howto>. This is NOT for SCSI
53           CD-ROMs.
54
55           To compile this driver as a module, choose M here and read
56           <file:Documentation/scsi/scsi.txt>.
57           The module will be called sd_mod.
58
59           Do not compile this driver as a module if your root file system
60           (the one containing the directory /) is located on a SCSI disk.
61           In this case, do not compile the driver for your SCSI host adapter
62           (below) as a module either.
63
64 config CHR_DEV_ST
65         tristate "SCSI tape support"
66         depends on SCSI
67         ---help---
68           If you want to use a SCSI tape drive under Linux, say Y and read the
69           SCSI-HOWTO, available from
70           <http://www.tldp.org/docs.html#howto>, and
71           <file:Documentation/scsi/st.txt> in the kernel source.  This is NOT
72           for SCSI CD-ROMs.
73
74           To compile this driver as a module, choose M here and read
75           <file:Documentation/scsi/scsi.txt>. The module will be called st.
76
77 config CHR_DEV_OSST
78         tristate "SCSI OnStream SC-x0 tape support"
79         depends on SCSI
80         ---help---
81           The OnStream SC-x0 SCSI tape drives can not be driven by the
82           standard st driver, but instead need this special osst driver and
83           use the  /dev/osstX char device nodes (major 206).  Via usb-storage
84           and ide-scsi, you may be able to drive the USB-x0 and DI-x0 drives
85           as well.  Note that there is also a second generation of OnStream
86           tape drives (ADR-x0) that supports the standard SCSI-2 commands for
87           tapes (QIC-157) and can be driven by the standard driver st.
88           For more information, you may have a look at the SCSI-HOWTO
89           <http://www.tldp.org/docs.html#howto>  and
90           <file:Documentation/scsi/osst.txt>  in the kernel source.
91           More info on the OnStream driver may be found on
92           <http://linux1.onstream.nl/test/>
93           Please also have a look at the standard st docu, as most of it
94           applies to osst as well.
95
96           To compile this driver as a module, choose M here and read
97           <file:Documentation/scsi/scsi.txt>. The module will be called osst.
98
99 config BLK_DEV_SR
100         tristate "SCSI CDROM support"
101         depends on SCSI
102         ---help---
103           If you want to use a SCSI or FireWire CD-ROM under Linux,
104           say Y and read the SCSI-HOWTO and the CDROM-HOWTO at
105           <http://www.tldp.org/docs.html#howto>. Also make sure to say
106           Y or M to "ISO 9660 CD-ROM file system support" later.
107
108           To compile this driver as a module, choose M here and read
109           <file:Documentation/scsi/scsi.txt>.
110           The module will be called sr_mod.
111
112 config BLK_DEV_SR_VENDOR
113         bool "Enable vendor-specific extensions (for SCSI CDROM)"
114         depends on BLK_DEV_SR
115         help
116           This enables the usage of vendor specific SCSI commands. This is
117           required to support multisession CDs with old NEC/TOSHIBA cdrom
118           drives (and HP Writers). If you have such a drive and get the first
119           session only, try saying Y here; everybody else says N.
120
121 config CHR_DEV_SG
122         tristate "SCSI generic support"
123         depends on SCSI
124         ---help---
125           If you want to use SCSI scanners, synthesizers or CD-writers or just
126           about anything having "SCSI" in its name other than hard disks,
127           CD-ROMs or tapes, say Y here. These won't be supported by the kernel
128           directly, so you need some additional software which knows how to
129           talk to these devices using the SCSI protocol:
130
131           For scanners, look at SANE (<http://www.mostang.com/sane/>). For CD
132           writer software look at Cdrtools
133           (<http://www.fokus.gmd.de/research/cc/glone/employees/joerg.schilling/private/cdrecord.html>)
134           and for burning a "disk at once": CDRDAO
135           (<http://cdrdao.sourceforge.net/>). Cdparanoia is a high
136           quality digital reader of audio CDs (<http://www.xiph.org/paranoia/>).
137           For other devices, it's possible that you'll have to write the
138           driver software yourself. Please read the file
139           <file:Documentation/scsi/scsi-generic.txt> for more information.
140
141           To compile this driver as a module, choose M here and read
142           <file:Documentation/scsi/scsi.txt>. The module will be called sg.
143
144           If unsure, say N.
145
146 config CHR_DEV_SCH
147         tristate "SCSI media changer support"
148         depends on SCSI
149         ---help---
150           This is a driver for SCSI media changers.  Most common devices are
151           tape libraries and MOD/CDROM jukeboxes.  *Real* jukeboxes, you
152           don't need this for those tiny 6-slot cdrom changers.  Media
153           changers are listed as "Type: Medium Changer" in /proc/scsi/scsi.
154           If you have such hardware and want to use it with linux, say Y
155           here.  Check <file:Documentation/scsi-changer.txt> for details.
156         
157           If you want to compile this as a module ( = code which can be
158           inserted in and removed from the running kernel whenever you want),
159           say M here and read <file:Documentation/modules.txt> and
160           <file:Documentation/scsi.txt>. The module will be called ch.o.
161           If unsure, say N.
162         
163
164 comment "Some SCSI devices (e.g. CD jukebox) support multiple LUNs"
165         depends on SCSI
166
167 config SCSI_MULTI_LUN
168         bool "Probe all LUNs on each SCSI device"
169         depends on SCSI
170         help
171           If you have a SCSI device that supports more than one LUN (Logical
172           Unit Number), e.g. a CD jukebox, and only one LUN is detected, you
173           can say Y here to force the SCSI driver to probe for multiple LUNs.
174           A SCSI device with multiple LUNs acts logically like multiple SCSI
175           devices. The vast majority of SCSI devices have only one LUN, and
176           so most people can say N here. The max_luns boot/module parameter 
177           allows to override this setting.
178
179 config SCSI_CONSTANTS
180         bool "Verbose SCSI error reporting (kernel size +=12K)"
181         depends on SCSI
182         help
183           The error messages regarding your SCSI hardware will be easier to
184           understand if you say Y here; it will enlarge your kernel by about
185           12 KB. If in doubt, say Y.
186
187 config SCSI_LOGGING
188         bool "SCSI logging facility"
189         depends on SCSI
190         ---help---
191           This turns on a logging facility that can be used to debug a number
192           of SCSI related problems.
193
194           If you say Y here, no logging output will appear by default, but you
195           can enable logging by saying Y to "/proc file system support" and
196           "Sysctl support" below and executing the command
197
198           echo "scsi log token [level]" > /proc/scsi/scsi
199
200           at boot time after the /proc file system has been mounted.
201
202           There are a number of things that can be used for 'token' (you can
203           find them in the source: <file:drivers/scsi/scsi.c>), and this
204           allows you to select the types of information you want, and the
205           level allows you to select the level of verbosity.
206
207           If you say N here, it may be harder to track down some types of SCSI
208           problems. If you say Y here your kernel will be somewhat larger, but
209           there should be no noticeable performance impact as long as you have
210           logging turned off.
211
212 menu "SCSI Transport Attributes"
213         depends on SCSI
214
215 config SCSI_SPI_ATTRS
216         tristate "Parallel SCSI (SPI) Transport Attributes"
217         depends on SCSI
218         help
219           If you wish to export transport-specific information about
220           each attached SCSI device to sysfs, say Y.  Otherwise, say N.
221
222 config SCSI_FC_ATTRS
223         tristate "FiberChannel Transport Attributes"
224         depends on SCSI
225         help
226           If you wish to export transport-specific information about
227           each attached FiberChannel device to sysfs, say Y.
228           Otherwise, say N.
229
230 config SCSI_ISCSI_ATTRS
231         tristate "iSCSI Transport Attributes"
232         depends on SCSI && NET
233         help
234           If you wish to export transport-specific information about
235           each attached iSCSI device to sysfs, say Y.
236           Otherwise, say N.
237
238 config SCSI_SAS_ATTRS
239         tristate "SAS Transport Attributes"
240         depends on SCSI
241         help
242           If you wish to export transport-specific information about
243           each attached SAS device to sysfs, say Y.
244
245 endmenu
246
247 menu "SCSI low-level drivers"
248         depends on SCSI!=n
249
250 config ISCSI_TCP
251         tristate "iSCSI Initiator over TCP/IP"
252         depends on SCSI && INET
253         select CRYPTO
254         select CRYPTO_MD5
255         select CRYPTO_CRC32C
256         select SCSI_ISCSI_ATTRS
257         help
258          The iSCSI Driver provides a host with the ability to access storage
259          through an IP network. The driver uses the iSCSI protocol to transport
260          SCSI requests and responses over a TCP/IP network between the host
261          (the "initiator") and "targets".  Architecturally, the iSCSI driver
262          combines with the host's TCP/IP stack, network drivers, and Network
263          Interface Card (NIC) to provide the same functions as a SCSI or a
264          Fibre Channel (FC) adapter driver with a Host Bus Adapter (HBA).
265
266          To compile this driver as a module, choose M here: the
267          module will be called iscsi_tcp.
268
269          The userspace component needed to initialize the driver, documentation,
270          and sample configuration files can be found here:
271
272          http://linux-iscsi.sf.net
273
274 config SGIWD93_SCSI
275         tristate "SGI WD93C93 SCSI Driver"
276         depends on SGI_IP22 && SCSI
277         help
278           If you have a Western Digital WD93 SCSI controller on
279           an SGI MIPS system, say Y.  Otherwise, say N.
280
281 config SCSI_DECNCR
282         tristate "DEC NCR53C94 Scsi Driver"
283         depends on MACH_DECSTATION && SCSI && TC
284         help
285           Say Y here to support the NCR53C94 SCSI controller chips on IOASIC
286           based TURBOchannel DECstations and TURBOchannel PMAZ-A cards.
287
288 config SCSI_DECSII
289         tristate "DEC SII Scsi Driver"
290         depends on MACH_DECSTATION && SCSI && 32BIT
291
292 config BLK_DEV_3W_XXXX_RAID
293         tristate "3ware 5/6/7/8xxx ATA-RAID support"
294         depends on PCI && SCSI
295         help
296           3ware is the only hardware ATA-Raid product in Linux to date.
297           This card is 2,4, or 8 channel master mode support only.
298           SCSI support required!!!
299
300           <http://www.3ware.com/>
301
302           Please read the comments at the top of
303           <file:drivers/scsi/3w-xxxx.c>.
304
305 config SCSI_3W_9XXX
306         tristate "3ware 9xxx SATA-RAID support"
307         depends on PCI && SCSI
308         help
309           This driver supports the 9000 series 3ware SATA-RAID cards.
310
311           <http://www.amcc.com>
312
313           Please read the comments at the top of
314           <file:drivers/scsi/3w-9xxx.c>.
315
316 config SCSI_7000FASST
317         tristate "7000FASST SCSI support"
318         depends on ISA && SCSI && ISA_DMA_API
319         help
320           This driver supports the Western Digital 7000 SCSI host adapter
321           family.  Some information is in the source:
322           <file:drivers/scsi/wd7000.c>.
323
324           To compile this driver as a module, choose M here: the
325           module will be called wd7000.
326
327 config SCSI_ACARD
328         tristate "ACARD SCSI support"
329         depends on PCI && SCSI
330         help
331           This driver supports the ACARD SCSI host adapter.
332           Support Chip <ATP870 ATP876 ATP880 ATP885>
333           To compile this driver as a module, choose M here: the
334           module will be called atp870u.
335
336 config SCSI_AHA152X
337         tristate "Adaptec AHA152X/2825 support"
338         depends on ISA && SCSI && !64BIT
339         select SCSI_SPI_ATTRS
340         ---help---
341           This is a driver for the AHA-1510, AHA-1520, AHA-1522, and AHA-2825
342           SCSI host adapters. It also works for the AVA-1505, but the IRQ etc.
343           must be manually specified in this case.
344
345           It is explained in section 3.3 of the SCSI-HOWTO, available from
346           <http://www.tldp.org/docs.html#howto>. You might also want to
347           read the file <file:Documentation/scsi/aha152x.txt>.
348
349           To compile this driver as a module, choose M here: the
350           module will be called aha152x.
351
352 config SCSI_AHA1542
353         tristate "Adaptec AHA1542 support"
354         depends on ISA && SCSI && ISA_DMA_API
355         ---help---
356           This is support for a SCSI host adapter.  It is explained in section
357           3.4 of the SCSI-HOWTO, available from
358           <http://www.tldp.org/docs.html#howto>.  Note that Trantor was
359           purchased by Adaptec, and some former Trantor products are being
360           sold under the Adaptec name.  If it doesn't work out of the box, you
361           may have to change some settings in <file:drivers/scsi/aha1542.h>.
362
363           To compile this driver as a module, choose M here: the
364           module will be called aha1542.
365
366 config SCSI_AHA1740
367         tristate "Adaptec AHA1740 support"
368         depends on EISA && SCSI
369         ---help---
370           This is support for a SCSI host adapter.  It is explained in section
371           3.5 of the SCSI-HOWTO, available from
372           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
373           of the box, you may have to change some settings in
374           <file:drivers/scsi/aha1740.h>.
375
376           To compile this driver as a module, choose M here: the
377           module will be called aha1740.
378
379 config SCSI_AACRAID
380         tristate "Adaptec AACRAID support"
381         depends on SCSI && PCI
382         help
383           This driver supports a variety of Dell, HP, Adaptec, IBM and
384           ICP storage products. For a list of supported products, refer
385           to <file:Documentation/scsi/aacraid.txt>.
386
387           To compile this driver as a module, choose M here: the module
388           will be called aacraid.
389
390
391 source "drivers/scsi/aic7xxx/Kconfig.aic7xxx"
392
393 config SCSI_AIC7XXX_OLD
394         tristate "Adaptec AIC7xxx support (old driver)"
395         depends on (ISA || EISA || PCI ) && SCSI
396         help
397           WARNING This driver is an older aic7xxx driver and is no longer
398           under active development.  Adaptec, Inc. is writing a new driver to
399           take the place of this one, and it is recommended that whenever
400           possible, people should use the new Adaptec written driver instead
401           of this one.  This driver will eventually be phased out entirely.
402
403           This is support for the various aic7xxx based Adaptec SCSI
404           controllers. These include the 274x EISA cards; 284x VLB cards;
405           2902, 2910, 293x, 294x, 394x, 3985 and several other PCI and
406           motherboard based SCSI controllers from Adaptec. It does not support
407           the AAA-13x RAID controllers from Adaptec, nor will it likely ever
408           support them. It does not support the 2920 cards from Adaptec that
409           use the Future Domain SCSI controller chip. For those cards, you
410           need the "Future Domain 16xx SCSI support" driver.
411
412           In general, if the controller is based on an Adaptec SCSI controller
413           chip from the aic777x series or the aic78xx series, this driver
414           should work. The only exception is the 7810 which is specifically
415           not supported (that's the RAID controller chip on the AAA-13x
416           cards).
417
418           Note that the AHA2920 SCSI host adapter is *not* supported by this
419           driver; choose "Future Domain 16xx SCSI support" instead if you have
420           one of those.
421
422           Information on the configuration options for this controller can be
423           found by checking the help file for each of the available
424           configuration options. You should read
425           <file:Documentation/scsi/aic7xxx_old.txt> at a minimum before
426           contacting the maintainer with any questions.  The SCSI-HOWTO,
427           available from <http://www.tldp.org/docs.html#howto>, can also
428           be of great help.
429
430           To compile this driver as a module, choose M here: the
431           module will be called aic7xxx_old.
432
433 source "drivers/scsi/aic7xxx/Kconfig.aic79xx"
434
435 # All the I2O code and drivers do not seem to be 64bit safe.
436 config SCSI_DPT_I2O
437         tristate "Adaptec I2O RAID support "
438         depends on !64BIT && SCSI && PCI
439         help
440           This driver supports all of Adaptec's I2O based RAID controllers as 
441           well as the DPT SmartRaid V cards.  This is an Adaptec maintained
442           driver by Deanna Bonds.  See <file:Documentation/scsi/dpti.txt>.
443
444           To compile this driver as a module, choose M here: the
445           module will be called dpt_i2o.
446
447 config SCSI_ADVANSYS
448         tristate "AdvanSys SCSI support"
449         depends on SCSI
450         depends on ISA || EISA || PCI
451         depends on BROKEN || X86_32
452         help
453           This is a driver for all SCSI host adapters manufactured by
454           AdvanSys. It is documented in the kernel source in
455           <file:drivers/scsi/advansys.c>.
456
457           To compile this driver as a module, choose M here: the
458           module will be called advansys.
459
460 config SCSI_IN2000
461         tristate "Always IN2000 SCSI support"
462         depends on ISA && SCSI
463         help
464           This is support for an ISA bus SCSI host adapter.  You'll find more
465           information in <file:Documentation/scsi/in2000.txt>. If it doesn't work
466           out of the box, you may have to change the jumpers for IRQ or
467           address selection.
468
469           To compile this driver as a module, choose M here: the
470           module will be called in2000.
471
472 source "drivers/scsi/megaraid/Kconfig.megaraid"
473
474 config SCSI_SATA
475         tristate "Serial ATA (SATA) support"
476         depends on SCSI
477         help
478           This driver family supports Serial ATA host controllers
479           and devices.
480
481           If unsure, say N.
482
483 config SCSI_SATA_AHCI
484         tristate "AHCI SATA support"
485         depends on SCSI_SATA && PCI
486         help
487           This option enables support for AHCI Serial ATA.
488
489           If unsure, say N.
490
491 config SCSI_SATA_SVW
492         tristate "ServerWorks Frodo / Apple K2 SATA support"
493         depends on SCSI_SATA && PCI
494         help
495           This option enables support for Broadcom/Serverworks/Apple K2
496           SATA support.
497
498           If unsure, say N.
499
500 config SCSI_ATA_PIIX
501         tristate "Intel PIIX/ICH SATA support"
502         depends on SCSI_SATA && PCI
503         help
504           This option enables support for ICH5/6/7/8 Serial ATA.
505           If PATA support was enabled previously, this enables
506           support for select Intel PIIX/ICH PATA host controllers.
507
508           If unsure, say N.
509
510 config SCSI_SATA_MV
511         tristate "Marvell SATA support (HIGHLY EXPERIMENTAL)"
512         depends on SCSI_SATA && PCI && EXPERIMENTAL
513         help
514           This option enables support for the Marvell Serial ATA family.
515           Currently supports 88SX[56]0[48][01] chips.
516
517           If unsure, say N.
518
519 config SCSI_SATA_NV
520         tristate "NVIDIA SATA support"
521         depends on SCSI_SATA && PCI && EXPERIMENTAL
522         help
523           This option enables support for NVIDIA Serial ATA.
524
525           If unsure, say N.
526
527 config SCSI_PDC_ADMA
528         tristate "Pacific Digital ADMA support"
529         depends on SCSI_SATA && PCI
530         help
531           This option enables support for Pacific Digital ADMA controllers
532
533           If unsure, say N.
534
535 config SCSI_HPTIOP
536         tristate "HighPoint RocketRAID 3xxx Controller support"
537         depends on SCSI && PCI
538         help
539           This option enables support for HighPoint RocketRAID 3xxx
540           controllers.
541
542           To compile this driver as a module, choose M here; the module
543           will be called hptiop. If unsure, say N.
544
545 config SCSI_SATA_QSTOR
546         tristate "Pacific Digital SATA QStor support"
547         depends on SCSI_SATA && PCI
548         help
549           This option enables support for Pacific Digital Serial ATA QStor.
550
551           If unsure, say N.
552
553 config SCSI_SATA_PROMISE
554         tristate "Promise SATA TX2/TX4 support"
555         depends on SCSI_SATA && PCI
556         help
557           This option enables support for Promise Serial ATA TX2/TX4.
558
559           If unsure, say N.
560
561 config SCSI_SATA_SX4
562         tristate "Promise SATA SX4 support"
563         depends on SCSI_SATA && PCI && EXPERIMENTAL
564         help
565           This option enables support for Promise Serial ATA SX4.
566
567           If unsure, say N.
568
569 config SCSI_SATA_SIL
570         tristate "Silicon Image SATA support"
571         depends on SCSI_SATA && PCI && EXPERIMENTAL
572         help
573           This option enables support for Silicon Image Serial ATA.
574
575           If unsure, say N.
576
577 config SCSI_SATA_SIL24
578         tristate "Silicon Image 3124/3132 SATA support"
579         depends on SCSI_SATA && PCI && EXPERIMENTAL
580         help
581           This option enables support for Silicon Image 3124/3132 Serial ATA.
582
583           If unsure, say N.
584
585 config SCSI_SATA_SIS
586         tristate "SiS 964/180 SATA support"
587         depends on SCSI_SATA && PCI && EXPERIMENTAL
588         help
589           This option enables support for SiS Serial ATA 964/180.
590
591           If unsure, say N.
592
593 config SCSI_SATA_ULI
594         tristate "ULi Electronics SATA support"
595         depends on SCSI_SATA && PCI && EXPERIMENTAL
596         help
597           This option enables support for ULi Electronics SATA.
598
599           If unsure, say N.
600
601 config SCSI_SATA_VIA
602         tristate "VIA SATA support"
603         depends on SCSI_SATA && PCI
604         help
605           This option enables support for VIA Serial ATA.
606
607           If unsure, say N.
608
609 config SCSI_SATA_VITESSE
610         tristate "VITESSE VSC-7174 / INTEL 31244 SATA support"
611         depends on SCSI_SATA && PCI
612         help
613           This option enables support for Vitesse VSC7174 and Intel 31244 Serial ATA.
614
615           If unsure, say N.
616
617 config SCSI_SATA_INTEL_COMBINED
618         bool
619         depends on IDE=y && !BLK_DEV_IDE_SATA && (SCSI_SATA_AHCI || SCSI_ATA_PIIX)
620         default y
621
622 config SCSI_BUSLOGIC
623         tristate "BusLogic SCSI support"
624         depends on (PCI || ISA || MCA) && SCSI && ISA_DMA_API
625         ---help---
626           This is support for BusLogic MultiMaster and FlashPoint SCSI Host
627           Adapters. Consult the SCSI-HOWTO, available from
628           <http://www.tldp.org/docs.html#howto>, and the files
629           <file:Documentation/scsi/BusLogic.txt> and
630           <file:Documentation/scsi/FlashPoint.txt> for more information.
631
632           To compile this driver as a module, choose M here: the
633           module will be called BusLogic.
634
635 config SCSI_OMIT_FLASHPOINT
636         bool "Omit FlashPoint support"
637         depends on SCSI_BUSLOGIC
638         help
639           This option allows you to omit the FlashPoint support from the
640           BusLogic SCSI driver. The FlashPoint SCCB Manager code is
641           substantial, so users of MultiMaster Host Adapters may wish to omit
642           it.
643
644 config SCSI_DMX3191D
645         tristate "DMX3191D SCSI support"
646         depends on PCI && SCSI
647         select SCSI_SPI_ATTRS
648         help
649           This is support for Domex DMX3191D SCSI Host Adapters.
650
651           To compile this driver as a module, choose M here: the
652           module will be called dmx3191d.
653
654 config SCSI_DTC3280
655         tristate "DTC3180/3280 SCSI support"
656         depends on ISA && SCSI
657         select SCSI_SPI_ATTRS
658         help
659           This is support for DTC 3180/3280 SCSI Host Adapters.  Please read
660           the SCSI-HOWTO, available from
661           <http://www.tldp.org/docs.html#howto>, and the file
662           <file:Documentation/scsi/dtc3x80.txt>.
663
664           To compile this driver as a module, choose M here: the
665           module will be called dtc.
666
667 config SCSI_EATA
668         tristate "EATA ISA/EISA/PCI (DPT and generic EATA/DMA-compliant boards) support"
669         depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
670         ---help---
671           This driver supports all EATA/DMA-compliant SCSI host adapters.  DPT
672           ISA and all EISA I/O addresses are probed looking for the "EATA"
673           signature. The addresses of all the PCI SCSI controllers reported
674           by the PCI subsystem are probed as well.
675
676           You want to read the start of <file:drivers/scsi/eata.c> and the
677           SCSI-HOWTO, available from
678           <http://www.tldp.org/docs.html#howto>.
679
680           To compile this driver as a module, choose M here: the
681           module will be called eata.
682
683 config SCSI_EATA_TAGGED_QUEUE
684         bool "enable tagged command queueing"
685         depends on SCSI_EATA
686         help
687           This is a feature of SCSI-2 which improves performance: the host
688           adapter can send several SCSI commands to a device's queue even if
689           previous commands haven't finished yet.
690           This is equivalent to the "eata=tc:y" boot option.
691
692 config SCSI_EATA_LINKED_COMMANDS
693         bool "enable elevator sorting"
694         depends on SCSI_EATA
695         help
696           This option enables elevator sorting for all probed SCSI disks and
697           CD-ROMs. It definitely reduces the average seek distance when doing
698           random seeks, but this does not necessarily result in a noticeable
699           performance improvement: your mileage may vary...
700           This is equivalent to the "eata=lc:y" boot option.
701
702 config SCSI_EATA_MAX_TAGS
703         int "maximum number of queued commands"
704         depends on SCSI_EATA
705         default "16"
706         help
707           This specifies how many SCSI commands can be maximally queued for
708           each probed SCSI device. You should reduce the default value of 16
709           only if you have disks with buggy or limited tagged command support.
710           Minimum is 2 and maximum is 62. This value is also the window size
711           used by the elevator sorting option above. The effective value used
712           by the driver for each probed SCSI device is reported at boot time.
713           This is equivalent to the "eata=mq:8" boot option.
714
715 config SCSI_EATA_PIO
716         tristate "EATA-PIO (old DPT PM2001, PM2012A) support"
717         depends on (ISA || EISA || PCI) && SCSI && BROKEN
718         ---help---
719           This driver supports all EATA-PIO protocol compliant SCSI Host
720           Adapters like the DPT PM2001 and the PM2012A.  EATA-DMA compliant
721           host adapters could also use this driver but are discouraged from
722           doing so, since this driver only supports hard disks and lacks
723           numerous features.  You might want to have a look at the SCSI-HOWTO,
724           available from <http://www.tldp.org/docs.html#howto>.
725
726           To compile this driver as a module, choose M here: the
727           module will be called eata_pio.
728
729 config SCSI_FUTURE_DOMAIN
730         tristate "Future Domain 16xx SCSI/AHA-2920A support"
731         depends on (ISA || PCI) && SCSI
732         ---help---
733           This is support for Future Domain's 16-bit SCSI host adapters
734           (TMC-1660/1680, TMC-1650/1670, TMC-3260, TMC-1610M/MER/MEX) and
735           other adapters based on the Future Domain chipsets (Quantum
736           ISA-200S, ISA-250MG; Adaptec AHA-2920A; and at least one IBM board).
737           It is explained in section 3.7 of the SCSI-HOWTO, available from
738           <http://www.tldp.org/docs.html#howto>.
739
740           NOTE: Newer Adaptec AHA-2920C boards use the Adaptec AIC-7850 chip
741           and should use the aic7xxx driver ("Adaptec AIC7xxx chipset SCSI
742           controller support"). This Future Domain driver works with the older
743           Adaptec AHA-2920A boards with a Future Domain chip on them.
744
745           To compile this driver as a module, choose M here: the
746           module will be called fdomain.
747
748 config SCSI_FD_MCS
749         tristate "Future Domain MCS-600/700 SCSI support"
750         depends on MCA_LEGACY && SCSI
751         ---help---
752           This is support for Future Domain MCS 600/700 MCA SCSI adapters.
753           Some PS/2 computers are equipped with IBM Fast SCSI Adapter/A which
754           is identical to the MCS 700 and hence also supported by this driver.
755           This driver also supports the Reply SB16/SCSI card (the SCSI part).
756           It supports multiple adapters in the same system.
757
758           To compile this driver as a module, choose M here: the
759           module will be called fd_mcs.
760
761 config SCSI_GDTH
762         tristate "Intel/ICP (former GDT SCSI Disk Array) RAID Controller support"
763         depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
764         ---help---
765           Formerly called GDT SCSI Disk Array Controller Support.
766
767           This is a driver for RAID/SCSI Disk Array Controllers (EISA/ISA/PCI) 
768           manufactured by Intel Corporation/ICP vortex GmbH. It is documented
769           in the kernel source in <file:drivers/scsi/gdth.c> and
770           <file:drivers/scsi/gdth.h.>
771
772           To compile this driver as a module, choose M here: the
773           module will be called gdth.
774
775 config SCSI_GENERIC_NCR5380
776         tristate "Generic NCR5380/53c400 SCSI PIO support"
777         depends on ISA && SCSI
778         select SCSI_SPI_ATTRS
779         ---help---
780           This is a driver for the old NCR 53c80 series of SCSI controllers
781           on boards using PIO. Most boards such as the Trantor T130 fit this
782           category, along with a large number of ISA 8bit controllers shipped
783           for free with SCSI scanners. If you have a PAS16, T128 or DMX3191
784           you should select the specific driver for that card rather than
785           generic 5380 support.
786
787           It is explained in section 3.8 of the SCSI-HOWTO, available from
788           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
789           of the box, you may have to change some settings in
790           <file:drivers/scsi/g_NCR5380.h>.
791
792           To compile this driver as a module, choose M here: the
793           module will be called g_NCR5380.
794
795 config SCSI_GENERIC_NCR5380_MMIO
796         tristate "Generic NCR5380/53c400 SCSI MMIO support"
797         depends on ISA && SCSI
798         select SCSI_SPI_ATTRS
799         ---help---
800           This is a driver for the old NCR 53c80 series of SCSI controllers
801           on boards using memory mapped I/O. 
802           It is explained in section 3.8 of the SCSI-HOWTO, available from
803           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
804           of the box, you may have to change some settings in
805           <file:drivers/scsi/g_NCR5380.h>.
806
807           To compile this driver as a module, choose M here: the
808           module will be called g_NCR5380_mmio.
809
810 config SCSI_GENERIC_NCR53C400
811         bool "Enable NCR53c400 extensions"
812         depends on SCSI_GENERIC_NCR5380
813         help
814           This enables certain optimizations for the NCR53c400 SCSI cards.
815           You might as well try it out.  Note that this driver will only probe
816           for the Trantor T130B in its default configuration; you might have
817           to pass a command line option to the kernel at boot time if it does
818           not detect your card.  See the file
819           <file:Documentation/scsi/g_NCR5380.txt> for details.
820
821 config SCSI_IBMMCA
822         tristate "IBMMCA SCSI support"
823         depends on MCA_LEGACY && SCSI
824         ---help---
825           This is support for the IBM SCSI adapter found in many of the PS/2
826           series computers.  These machines have an MCA bus, so you need to
827           answer Y to "MCA support" as well and read
828           <file:Documentation/mca.txt>.
829
830           If the adapter isn't found during boot (a common problem for models
831           56, 57, 76, and 77) you'll need to use the 'ibmmcascsi=<pun>' kernel
832           option, where <pun> is the id of the SCSI subsystem (usually 7, but
833           if that doesn't work check your reference diskette).  Owners of
834           model 95 with a LED-matrix-display can in addition activate some
835           activity info like under OS/2, but more informative, by setting
836           'ibmmcascsi=display' as an additional kernel parameter.  Try "man
837           bootparam" or see the documentation of your boot loader about how to
838           pass options to the kernel.
839
840           To compile this driver as a module, choose M here: the
841           module will be called ibmmca.
842
843 config IBMMCA_SCSI_ORDER_STANDARD
844         bool "Standard SCSI-order"
845         depends on SCSI_IBMMCA
846         ---help---
847           In the PC-world and in most modern SCSI-BIOS-setups, SCSI-hard disks
848           are assigned to the drive letters, starting with the lowest SCSI-id
849           (physical number -- pun) to be drive C:, as seen from DOS and
850           similar operating systems. When looking into papers describing the
851           ANSI-SCSI-standard, this assignment of drives appears to be wrong.
852           The SCSI-standard follows a hardware-hierarchy which says that id 7
853           has the highest priority and id 0 the lowest. Therefore, the host
854           adapters are still today everywhere placed as SCSI-id 7 by default.
855           In the SCSI-standard, the drive letters express the priority of the
856           disk. C: should be the hard disk, or a partition on it, with the
857           highest priority. This must therefore be the disk with the highest
858           SCSI-id (e.g. 6) and not the one with the lowest! IBM-BIOS kept the
859           original definition of the SCSI-standard as also industrial- and
860           process-control-machines, like VME-CPUs running under realtime-OSes
861           (e.g. LynxOS, OS9) do.
862
863           If you like to run Linux on your MCA-machine with the same
864           assignment of hard disks as seen from e.g. DOS or OS/2 on your
865           machine, which is in addition conformant to the SCSI-standard, you
866           must say Y here. This is also necessary for MCA-Linux users who want
867           to keep downward compatibility to older releases of the
868           IBM-MCA-SCSI-driver (older than driver-release 2.00 and older than
869           June 1997).
870
871           If you like to have the lowest SCSI-id assigned as drive C:, as
872           modern SCSI-BIOSes do, which does not conform to the standard, but
873           is widespread and common in the PC-world of today, you must say N
874           here. If unsure, say Y.
875
876 config IBMMCA_SCSI_DEV_RESET
877         bool "Reset SCSI-devices at boottime"
878         depends on SCSI_IBMMCA
879         ---help---
880           By default, SCSI-devices are reset when the machine is powered on.
881           However, some devices exist, like special-control-devices,
882           SCSI-CNC-machines, SCSI-printer or scanners of older type, that do
883           not reset when switched on. If you say Y here, each device connected
884           to your SCSI-bus will be issued a reset-command after it has been
885           probed, while the kernel is booting. This may cause problems with
886           more modern devices, like hard disks, which do not appreciate these
887           reset commands, and can cause your system to hang. So say Y only if
888           you know that one of your older devices needs it; N is the safe
889           answer.
890
891 config SCSI_IPS
892         tristate "IBM ServeRAID support"
893         depends on PCI && SCSI
894         ---help---
895           This is support for the IBM ServeRAID hardware RAID controllers.
896           See <http://www.developer.ibm.com/welcome/netfinity/serveraid.html>
897           for more information.  If this driver does not work correctly
898           without modification please contact the author by email at
899           <ipslinux@adaptec.com>.
900
901           To compile this driver as a module, choose M here: the
902           module will be called ips.
903
904 config SCSI_IBMVSCSI
905         tristate "IBM Virtual SCSI support"
906         depends on PPC_PSERIES || PPC_ISERIES
907         help
908           This is the IBM POWER Virtual SCSI Client
909
910           To compile this driver as a module, choose M here: the
911           module will be called ibmvscsic.
912
913 config SCSI_INITIO
914         tristate "Initio 9100U(W) support"
915         depends on PCI && SCSI
916         help
917           This is support for the Initio 91XXU(W) SCSI host adapter.  Please
918           read the SCSI-HOWTO, available from
919           <http://www.tldp.org/docs.html#howto>.
920
921           To compile this driver as a module, choose M here: the
922           module will be called initio.
923
924 config SCSI_INIA100
925         tristate "Initio INI-A100U2W support"
926         depends on PCI && SCSI
927         help
928           This is support for the Initio INI-A100U2W SCSI host adapter.
929           Please read the SCSI-HOWTO, available from
930           <http://www.tldp.org/docs.html#howto>.
931
932           To compile this driver as a module, choose M here: the
933           module will be called a100u2w.
934
935 config SCSI_PPA
936         tristate "IOMEGA parallel port (ppa - older drives)"
937         depends on SCSI && PARPORT_PC
938         ---help---
939           This driver supports older versions of IOMEGA's parallel port ZIP
940           drive (a 100 MB removable media device).
941
942           Note that you can say N here if you have the SCSI version of the ZIP
943           drive: it will be supported automatically if you said Y to the
944           generic "SCSI disk support", above.
945
946           If you have the ZIP Plus drive or a more recent parallel port ZIP
947           drive (if the supplied cable with the drive is labeled "AutoDetect")
948           then you should say N here and Y to "IOMEGA parallel port (imm -
949           newer drives)", below.
950
951           For more information about this driver and how to use it you should
952           read the file <file:Documentation/scsi/ppa.txt>.  You should also read
953           the SCSI-HOWTO, which is available from
954           <http://www.tldp.org/docs.html#howto>.  If you use this driver,
955           you will still be able to use the parallel port for other tasks,
956           such as a printer; it is safe to compile both drivers into the
957           kernel.
958
959           To compile this driver as a module, choose M here: the
960           module will be called ppa.
961
962 config SCSI_IMM
963         tristate "IOMEGA parallel port (imm - newer drives)"
964         depends on SCSI && PARPORT_PC
965         ---help---
966           This driver supports newer versions of IOMEGA's parallel port ZIP
967           drive (a 100 MB removable media device).
968
969           Note that you can say N here if you have the SCSI version of the ZIP
970           drive: it will be supported automatically if you said Y to the
971           generic "SCSI disk support", above.
972
973           If you have the ZIP Plus drive or a more recent parallel port ZIP
974           drive (if the supplied cable with the drive is labeled "AutoDetect")
975           then you should say Y here; if you have an older ZIP drive, say N
976           here and Y to "IOMEGA Parallel Port (ppa - older drives)", above.
977
978           For more information about this driver and how to use it you should
979           read the file <file:Documentation/scsi/ppa.txt>.  You should also read
980           the SCSI-HOWTO, which is available from
981           <http://www.tldp.org/docs.html#howto>.  If you use this driver,
982           you will still be able to use the parallel port for other tasks,
983           such as a printer; it is safe to compile both drivers into the
984           kernel.
985
986           To compile this driver as a module, choose M here: the
987           module will be called imm.
988
989 config SCSI_IZIP_EPP16
990         bool "ppa/imm option - Use slow (but safe) EPP-16"
991         depends on SCSI_PPA || SCSI_IMM
992         ---help---
993           EPP (Enhanced Parallel Port) is a standard for parallel ports which
994           allows them to act as expansion buses that can handle up to 64
995           peripheral devices.
996
997           Some parallel port chipsets are slower than their motherboard, and
998           so we have to control the state of the chipset's FIFO queue every
999           now and then to avoid data loss. This will be done if you say Y
1000           here.
1001
1002           Generally, saying Y is the safe option and slows things down a bit.
1003
1004 config SCSI_IZIP_SLOW_CTR
1005         bool "ppa/imm option - Assume slow parport control register"
1006         depends on SCSI_PPA || SCSI_IMM
1007         help
1008           Some parallel ports are known to have excessive delays between
1009           changing the parallel port control register and good data being
1010           available on the parallel port data/status register. This option
1011           forces a small delay (1.0 usec to be exact) after changing the
1012           control register to let things settle out. Enabling this option may
1013           result in a big drop in performance but some very old parallel ports
1014           (found in 386 vintage machines) will not work properly.
1015
1016           Generally, saying N is fine.
1017
1018 config SCSI_NCR53C406A
1019         tristate "NCR53c406a SCSI support"
1020         depends on ISA && SCSI
1021         help
1022           This is support for the NCR53c406a SCSI host adapter.  For user
1023           configurable parameters, check out <file:drivers/scsi/NCR53c406a.c>
1024           in the kernel source.  Also read the SCSI-HOWTO, available from
1025           <http://www.tldp.org/docs.html#howto>.
1026
1027           To compile this driver as a module, choose M here: the
1028           module will be called NCR53c406.
1029
1030 config SCSI_NCR_D700
1031         tristate "NCR Dual 700 MCA SCSI support"
1032         depends on MCA && SCSI
1033         select SCSI_SPI_ATTRS
1034         help
1035           This is a driver for the MicroChannel Dual 700 card produced by
1036           NCR and commonly used in 345x/35xx/4100 class machines.  It always
1037           tries to negotiate sync and uses tag command queueing.
1038
1039           Unless you have an NCR manufactured machine, the chances are that
1040           you do not have this SCSI card, so say N.
1041
1042 config SCSI_LASI700
1043         tristate "HP Lasi SCSI support for 53c700/710"
1044         depends on GSC && SCSI
1045         select SCSI_SPI_ATTRS
1046         help
1047           This is a driver for the SCSI controller in the Lasi chip found in
1048           many PA-RISC workstations & servers.  If you do not know whether you
1049           have a Lasi chip, it is safe to say "Y" here.
1050
1051 config 53C700_LE_ON_BE
1052         bool
1053         depends on SCSI_LASI700
1054         default y
1055
1056 config SCSI_SYM53C8XX_2
1057         tristate "SYM53C8XX Version 2 SCSI support"
1058         depends on PCI && SCSI
1059         select SCSI_SPI_ATTRS
1060         ---help---
1061           This driver supports the whole NCR53C8XX/SYM53C8XX family of
1062           PCI-SCSI controllers.  It also supports the subset of LSI53C10XX
1063           Ultra-160 controllers that are based on the SYM53C8XX SCRIPTS
1064           language.  It does not support LSI53C10XX Ultra-320 PCI-X SCSI
1065           controllers; you need to use the Fusion MPT driver for that.
1066
1067           Please read <file:Documentation/scsi/sym53c8xx_2.txt> for more
1068           information.
1069
1070 config SCSI_SYM53C8XX_DMA_ADDRESSING_MODE
1071         int "DMA addressing mode"
1072         depends on SCSI_SYM53C8XX_2
1073         default "1"
1074         ---help---
1075           This option only applies to PCI-SCSI chips that are PCI DAC
1076           capable (875A, 895A, 896, 1010-33, 1010-66, 1000).
1077
1078           When set to 0, the driver will program the chip to only perform
1079           32-bit DMA.  When set to 1, the chip will be able to perform DMA
1080           to addresses up to 1TB.  When set to 2, the driver supports the
1081           full 64-bit DMA address range, but can only address 16 segments
1082           of 4 GB each.  This limits the total addressable range to 64 GB.
1083
1084           Most machines with less than 4GB of memory should use a setting
1085           of 0 for best performance.  If your machine has 4GB of memory
1086           or more, you should set this option to 1 (the default).
1087
1088           The still experimental value 2 (64 bit DMA addressing with 16
1089           x 4GB segments limitation) can be used on systems that require
1090           PCI address bits past bit 39 to be set for the addressing of
1091           memory using PCI DAC cycles.
1092
1093 config SCSI_SYM53C8XX_DEFAULT_TAGS
1094         int "Default tagged command queue depth"
1095         depends on SCSI_SYM53C8XX_2
1096         default "16"
1097         help
1098           This is the default value of the command queue depth the
1099           driver will announce to the generic SCSI layer for devices
1100           that support tagged command queueing. This value can be changed
1101           from the boot command line.  This is a soft limit that cannot
1102           exceed CONFIG_SCSI_SYM53C8XX_MAX_TAGS.
1103
1104 config SCSI_SYM53C8XX_MAX_TAGS
1105         int "Maximum number of queued commands"
1106         depends on SCSI_SYM53C8XX_2
1107         default "64"
1108         help
1109           This option allows you to specify the maximum number of commands
1110           that can be queued to any device, when tagged command queuing is
1111           possible. The driver supports up to 256 queued commands per device.
1112           This value is used as a compiled-in hard limit.
1113
1114 config SCSI_SYM53C8XX_MMIO
1115         bool "Use memory mapped IO"
1116         depends on SCSI_SYM53C8XX_2
1117         default y
1118         help
1119           Memory mapped IO is faster than Port IO.  Most people should
1120           answer Y here, but some machines may have problems.  If you have
1121           to answer N here, please report the problem to the maintainer.
1122
1123 config SCSI_IPR
1124         tristate "IBM Power Linux RAID adapter support"
1125         depends on PCI && SCSI
1126         select FW_LOADER
1127         ---help---
1128           This driver supports the IBM Power Linux family RAID adapters.
1129           This includes IBM pSeries 5712, 5703, 5709, and 570A, as well
1130           as IBM iSeries 5702, 5703, 5709, and 570A.
1131
1132 config SCSI_IPR_TRACE
1133         bool "enable driver internal trace"
1134         depends on SCSI_IPR
1135         help
1136           If you say Y here, the driver will trace all commands issued
1137           to the adapter. Performance impact is minimal. Trace can be
1138           dumped using /sys/bus/class/scsi_host/hostXX/trace.
1139
1140 config SCSI_IPR_DUMP
1141         bool "enable adapter dump support"
1142         depends on SCSI_IPR
1143         help
1144           If you say Y here, the driver will support adapter crash dump.
1145           If you enable this support, the iprdump daemon can be used
1146           to capture adapter failure analysis information.
1147
1148 config SCSI_ZALON
1149         tristate "Zalon SCSI support"
1150         depends on GSC && SCSI
1151         select SCSI_SPI_ATTRS
1152         help
1153           The Zalon is a GSC/HSC bus interface chip that sits between the
1154           PA-RISC processor and the NCR 53c720 SCSI controller on C100,
1155           C110, J200, J210 and some D, K & R-class machines.  It's also
1156           used on the add-in Bluefish, Barracuda & Shrike SCSI cards.
1157           Say Y here if you have one of these machines or cards.
1158
1159 config SCSI_NCR_Q720
1160         tristate "NCR Quad 720 MCA SCSI support"
1161         depends on MCA && SCSI
1162         select SCSI_SPI_ATTRS
1163         help
1164           This is a driver for the MicroChannel Quad 720 card produced by
1165           NCR and commonly used in 345x/35xx/4100 class machines.  It always
1166           tries to negotiate sync and uses tag command queueing.
1167
1168           Unless you have an NCR manufactured machine, the chances are that
1169           you do not have this SCSI card, so say N.
1170
1171 config SCSI_NCR53C8XX_DEFAULT_TAGS
1172         int "default tagged command queue depth"
1173         depends on SCSI_ZALON || SCSI_NCR_Q720
1174         default "8"
1175         ---help---
1176           "Tagged command queuing" is a feature of SCSI-2 which improves
1177           performance: the host adapter can send several SCSI commands to a
1178           device's queue even if previous commands haven't finished yet.
1179           Because the device is intelligent, it can optimize its operations
1180           (like head positioning) based on its own request queue. Some SCSI
1181           devices don't implement this properly; if you want to disable this
1182           feature, enter 0 or 1 here (it doesn't matter which).
1183
1184           The default value is 8 and should be supported by most hard disks.
1185           This value can be overridden from the boot command line using the
1186           'tags' option as follows (example):
1187           'ncr53c8xx=tags:4/t2t3q16/t0u2q10' will set default queue depth to
1188           4, set queue depth to 16 for target 2 and target 3 on controller 0
1189           and set queue depth to 10 for target 0 / lun 2 on controller 1.
1190
1191           The normal answer therefore is to go with the default 8 and to use
1192           a boot command line option for devices that need to use a different
1193           command queue depth.
1194
1195           There is no safe option other than using good SCSI devices.
1196
1197 config SCSI_NCR53C8XX_MAX_TAGS
1198         int "maximum number of queued commands"
1199         depends on SCSI_ZALON || SCSI_NCR_Q720
1200         default "32"
1201         ---help---
1202           This option allows you to specify the maximum number of commands
1203           that can be queued to any device, when tagged command queuing is
1204           possible. The default value is 32. Minimum is 2, maximum is 64.
1205           Modern hard disks are able to support 64 tags and even more, but
1206           do not seem to be faster when more than 32 tags are being used.
1207
1208           So, the normal answer here is to go with the default value 32 unless
1209           you are using very large hard disks with large cache (>= 1 MB) that
1210           are able to take advantage of more than 32 tagged commands.
1211
1212           There is no safe option and the default answer is recommended.
1213
1214 config SCSI_NCR53C8XX_SYNC
1215         int "synchronous transfers frequency in MHz"
1216         depends on SCSI_ZALON || SCSI_NCR_Q720
1217         default "20"
1218         ---help---
1219           The SCSI Parallel Interface-2 Standard defines 5 classes of transfer
1220           rates: FAST-5, FAST-10, FAST-20, FAST-40 and FAST-80.  The numbers
1221           are respectively the maximum data transfer rates in mega-transfers
1222           per second for each class.  For example, a FAST-20 Wide 16 device is
1223           able to transfer data at 20 million 16 bit packets per second for a
1224           total rate of 40 MB/s.
1225
1226           You may specify 0 if you want to only use asynchronous data
1227           transfers. This is the safest and slowest option. Otherwise, specify
1228           a value between 5 and 80, depending on the capability of your SCSI
1229           controller.  The higher the number, the faster the data transfer.
1230           Note that 80 should normally be ok since the driver decreases the
1231           value automatically according to the controller's capabilities.
1232
1233           Your answer to this question is ignored for controllers with NVRAM,
1234           since the driver will get this information from the user set-up.  It
1235           also can be overridden using a boot setup option, as follows
1236           (example): 'ncr53c8xx=sync:12' will allow the driver to negotiate
1237           for FAST-20 synchronous data transfer (20 mega-transfers per
1238           second).
1239
1240           The normal answer therefore is not to go with the default but to
1241           select the maximum value 80 allowing the driver to use the maximum
1242           value supported by each controller. If this causes problems with
1243           your SCSI devices, you should come back and decrease the value.
1244
1245           There is no safe option other than using good cabling, right
1246           terminations and SCSI conformant devices.
1247
1248 config SCSI_NCR53C8XX_PROFILE
1249         bool "enable profiling"
1250         depends on SCSI_ZALON || SCSI_NCR_Q720
1251         help
1252           This option allows you to enable profiling information gathering.
1253           These statistics are not very accurate due to the low frequency
1254           of the kernel clock (100 Hz on i386) and have performance impact
1255           on systems that use very fast devices.
1256
1257           The normal answer therefore is N.
1258
1259 config SCSI_NCR53C8XX_NO_DISCONNECT
1260         bool "not allow targets to disconnect"
1261         depends on (SCSI_ZALON || SCSI_NCR_Q720) && SCSI_NCR53C8XX_DEFAULT_TAGS=0
1262         help
1263           This option is only provided for safety if you suspect some SCSI
1264           device of yours to not support properly the target-disconnect
1265           feature. In that case, you would say Y here. In general however, to
1266           not allow targets to disconnect is not reasonable if there is more
1267           than 1 device on a SCSI bus. The normal answer therefore is N.
1268
1269 config SCSI_MCA_53C9X
1270         tristate "NCR MCA 53C9x SCSI support"
1271         depends on MCA_LEGACY && SCSI && BROKEN_ON_SMP
1272         help
1273           Some MicroChannel machines, notably the NCR 35xx line, use a SCSI
1274           controller based on the NCR 53C94.  This driver will allow use of
1275           the controller on the 3550, and very possibly others.
1276
1277           To compile this driver as a module, choose M here: the
1278           module will be called mca_53c9x.
1279
1280 config SCSI_PAS16
1281         tristate "PAS16 SCSI support"
1282         depends on ISA && SCSI
1283         select SCSI_SPI_ATTRS
1284         ---help---
1285           This is support for a SCSI host adapter.  It is explained in section
1286           3.10 of the SCSI-HOWTO, available from
1287           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
1288           of the box, you may have to change some settings in
1289           <file:drivers/scsi/pas16.h>.
1290
1291           To compile this driver as a module, choose M here: the
1292           module will be called pas16.
1293
1294 config SCSI_PSI240I
1295         tristate "PSI240i support"
1296         depends on ISA && SCSI
1297         help
1298           This is support for the PSI240i EIDE interface card which acts as a
1299           SCSI host adapter.  Please read the SCSI-HOWTO, available from
1300           <http://www.tldp.org/docs.html#howto>.
1301
1302           To compile this driver as a module, choose M here: the
1303           module will be called psi240i.
1304
1305 config SCSI_QLOGIC_FAS
1306         tristate "Qlogic FAS SCSI support"
1307         depends on ISA && SCSI
1308         ---help---
1309           This is a driver for the ISA, VLB, and PCMCIA versions of the Qlogic
1310           FastSCSI! cards as well as any other card based on the FASXX chip
1311           (including the Control Concepts SCSI/IDE/SIO/PIO/FDC cards).
1312
1313           This driver does NOT support the PCI versions of these cards. The
1314           PCI versions are supported by the Qlogic ISP driver ("Qlogic ISP
1315           SCSI support"), below.
1316
1317           Information about this driver is contained in
1318           <file:Documentation/scsi/qlogicfas.txt>.  You should also read the
1319           SCSI-HOWTO, available from
1320           <http://www.tldp.org/docs.html#howto>.
1321
1322           To compile this driver as a module, choose M here: the
1323           module will be called qlogicfas.
1324
1325 config SCSI_QLOGIC_FC_FIRMWARE
1326         bool "Include loadable firmware in driver"
1327         depends on SCSI_QLOGIC_FC
1328         help
1329           Say Y to include ISP2X00 Fabric Initiator/Target Firmware, with
1330           expanded LUN addressing and FcTape (FCP-2) support, in the
1331           qlogicfc driver. This is required on some platforms.
1332
1333 config SCSI_QLOGIC_1280
1334         tristate "Qlogic QLA 1240/1x80/1x160 SCSI support"
1335         depends on PCI && SCSI
1336         help
1337           Say Y if you have a QLogic ISP1240/1x80/1x160 SCSI host adapter.
1338
1339           To compile this driver as a module, choose M here: the
1340           module will be called qla1280.
1341
1342 config SCSI_QLOGICPTI
1343         tristate "PTI Qlogic, ISP Driver"
1344         depends on SBUS && SCSI
1345         help
1346           This driver supports SBUS SCSI controllers from PTI or QLogic. These
1347           controllers are known under Solaris as qpti and in the openprom as
1348           PTI,ptisp or QLGC,isp. Note that PCI QLogic SCSI controllers are
1349           driven by a different driver.
1350
1351           To compile this driver as a module, choose M here: the
1352           module will be called qlogicpti.
1353
1354 source "drivers/scsi/qla2xxx/Kconfig"
1355
1356 config SCSI_LPFC
1357         tristate "Emulex LightPulse Fibre Channel Support"
1358         depends on PCI && SCSI
1359         select SCSI_FC_ATTRS
1360         help
1361           This lpfc driver supports the Emulex LightPulse
1362           Family of Fibre Channel PCI host adapters.
1363
1364 config SCSI_SEAGATE
1365         tristate "Seagate ST-02 and Future Domain TMC-8xx SCSI support"
1366         depends on X86 && ISA && SCSI && BROKEN
1367         ---help---
1368           These are 8-bit SCSI controllers; the ST-01 is also supported by
1369           this driver.  It is explained in section 3.9 of the SCSI-HOWTO,
1370           available from <http://www.tldp.org/docs.html#howto>.  If it
1371           doesn't work out of the box, you may have to change some settings in
1372           <file:drivers/scsi/seagate.h>.
1373
1374           To compile this driver as a module, choose M here: the
1375           module will be called seagate.
1376
1377 # definitely looks not 64bit safe:
1378 config SCSI_SIM710
1379         tristate "Simple 53c710 SCSI support (Compaq, NCR machines)"
1380         depends on (EISA || MCA) && SCSI
1381         select SCSI_SPI_ATTRS
1382         ---help---
1383           This driver for NCR53c710 based SCSI host adapters.
1384
1385           It currently supports Compaq EISA cards and NCR MCA cards
1386
1387 config 53C700_IO_MAPPED
1388         bool
1389         depends on SCSI_SIM710
1390         default y
1391
1392 config SCSI_SYM53C416
1393         tristate "Symbios 53c416 SCSI support"
1394         depends on ISA && SCSI
1395         ---help---
1396           This is support for the sym53c416 SCSI host adapter, the SCSI
1397           adapter that comes with some HP scanners. This driver requires that
1398           the sym53c416 is configured first using some sort of PnP
1399           configuration program (e.g. isapnp) or by a PnP aware BIOS. If you
1400           are using isapnp then you need to compile this driver as a module
1401           and then load it using insmod after isapnp has run. The parameters
1402           of the configured card(s) should be passed to the driver. The format
1403           is:
1404
1405           insmod sym53c416 sym53c416=<base>,<irq> [sym53c416_1=<base>,<irq>]
1406
1407           To compile this driver as a module, choose M here: the
1408           module will be called sym53c416.
1409
1410 config SCSI_DC395x
1411         tristate "Tekram DC395(U/UW/F) and DC315(U) SCSI support (EXPERIMENTAL)"
1412         depends on PCI && SCSI && EXPERIMENTAL
1413         ---help---
1414           This driver supports PCI SCSI host adapters based on the ASIC
1415           TRM-S1040 chip, e.g Tekram DC395(U/UW/F) and DC315(U) variants.
1416
1417           This driver works, but is still in experimental status. So better
1418           have a bootable disk and a backup in case of emergency.
1419
1420           Documentation can be found in <file:Documentation/scsi/dc395x.txt>.
1421
1422           To compile this driver as a module, choose M here: the
1423           module will be called dc395x.
1424
1425 config SCSI_DC390T
1426         tristate "Tekram DC390(T) and Am53/79C974 SCSI support"
1427         depends on PCI && SCSI
1428         ---help---
1429           This driver supports PCI SCSI host adapters based on the Am53C974A
1430           chip, e.g. Tekram DC390(T), DawiControl 2974 and some onboard
1431           PCscsi/PCnet (Am53/79C974) solutions.
1432
1433           Documentation can be found in <file:Documentation/scsi/tmscsim.txt>.
1434
1435           Note that this driver does NOT support Tekram DC390W/U/F, which are
1436           based on NCR/Symbios chips. Use "NCR53C8XX SCSI support" for those.
1437
1438           To compile this driver as a module, choose M here: the
1439           module will be called tmscsim.
1440
1441 config SCSI_T128
1442         tristate "Trantor T128/T128F/T228 SCSI support"
1443         depends on ISA && SCSI
1444         select SCSI_SPI_ATTRS
1445         ---help---
1446           This is support for a SCSI host adapter. It is explained in section
1447           3.11 of the SCSI-HOWTO, available from
1448           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
1449           of the box, you may have to change some settings in
1450           <file:drivers/scsi/t128.h>.  Note that Trantor was purchased by
1451           Adaptec, and some former Trantor products are being sold under the
1452           Adaptec name.
1453
1454           To compile this driver as a module, choose M here: the
1455           module will be called t128.
1456
1457 config SCSI_U14_34F
1458         tristate "UltraStor 14F/34F support"
1459         depends on ISA && SCSI && ISA_DMA_API
1460         ---help---
1461           This is support for the UltraStor 14F and 34F SCSI-2 host adapters.
1462           The source at <file:drivers/scsi/u14-34f.c> contains some
1463           information about this hardware.  If the driver doesn't work out of
1464           the box, you may have to change some settings in
1465           <file: drivers/scsi/u14-34f.c>.  Read the SCSI-HOWTO, available from
1466           <http://www.tldp.org/docs.html#howto>.  Note that there is also
1467           another driver for the same hardware: "UltraStor SCSI support",
1468           below.  You should say Y to both only if you want 24F support as
1469           well.
1470
1471           To compile this driver as a module, choose M here: the
1472           module will be called u14-34f.
1473
1474 config SCSI_U14_34F_TAGGED_QUEUE
1475         bool "enable tagged command queueing"
1476         depends on SCSI_U14_34F
1477         help
1478           This is a feature of SCSI-2 which improves performance: the host
1479           adapter can send several SCSI commands to a device's queue even if
1480           previous commands haven't finished yet.
1481           This is equivalent to the "u14-34f=tc:y" boot option.
1482
1483 config SCSI_U14_34F_LINKED_COMMANDS
1484         bool "enable elevator sorting"
1485         depends on SCSI_U14_34F
1486         help
1487           This option enables elevator sorting for all probed SCSI disks and
1488           CD-ROMs. It definitely reduces the average seek distance when doing
1489           random seeks, but this does not necessarily result in a noticeable
1490           performance improvement: your mileage may vary...
1491           This is equivalent to the "u14-34f=lc:y" boot option.
1492
1493 config SCSI_U14_34F_MAX_TAGS
1494         int "maximum number of queued commands"
1495         depends on SCSI_U14_34F
1496         default "8"
1497         help
1498           This specifies how many SCSI commands can be maximally queued for
1499           each probed SCSI device. You should reduce the default value of 8
1500           only if you have disks with buggy or limited tagged command support.
1501           Minimum is 2 and maximum is 14. This value is also the window size
1502           used by the elevator sorting option above. The effective value used
1503           by the driver for each probed SCSI device is reported at boot time.
1504           This is equivalent to the "u14-34f=mq:8" boot option.
1505
1506 config SCSI_ULTRASTOR
1507         tristate "UltraStor SCSI support"
1508         depends on X86 && ISA && SCSI
1509         ---help---
1510           This is support for the UltraStor 14F, 24F and 34F SCSI-2 host
1511           adapter family.  This driver is explained in section 3.12 of the
1512           SCSI-HOWTO, available from
1513           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
1514           of the box, you may have to change some settings in
1515           <file:drivers/scsi/ultrastor.h>.
1516
1517           Note that there is also another driver for the same hardware:
1518           "UltraStor 14F/34F support", above.
1519
1520           To compile this driver as a module, choose M here: the
1521           module will be called ultrastor.
1522
1523 config SCSI_NSP32
1524         tristate "Workbit NinjaSCSI-32Bi/UDE support"
1525         depends on PCI && SCSI && !64BIT
1526         help
1527           This is support for the Workbit NinjaSCSI-32Bi/UDE PCI/Cardbus
1528           SCSI host adapter. Please read the SCSI-HOWTO, available from
1529           <http://www.tldp.org/docs.html#howto>.
1530
1531           To compile this driver as a module, choose M here: the
1532           module will be called nsp32.
1533
1534 config SCSI_DEBUG
1535         tristate "SCSI debugging host simulator"
1536         depends on SCSI
1537         help
1538           This is a host adapter simulator that can simulate multiple hosts
1539           each with multiple dummy SCSI devices (disks). It defaults to one
1540           host adapter with one dummy SCSI disk. Each dummy disk uses kernel
1541           RAM as storage (i.e. it is a ramdisk). To save space when multiple
1542           dummy disks are simulated, they share the same kernel RAM for 
1543           their storage. See <http://www.torque.net/sg/sdebug.html> for more
1544           information. This driver is primarily of use to those testing the
1545           SCSI and block subsystems. If unsure, say N.
1546
1547 config SCSI_MESH
1548         tristate "MESH (Power Mac internal SCSI) support"
1549         depends on PPC32 && PPC_PMAC && SCSI
1550         help
1551           Many Power Macintoshes and clones have a MESH (Macintosh Enhanced
1552           SCSI Hardware) SCSI bus adaptor (the 7200 doesn't, but all of the
1553           other Power Macintoshes do). Say Y to include support for this SCSI
1554           adaptor.
1555
1556           To compile this driver as a module, choose M here: the
1557           module will be called mesh.
1558
1559 config SCSI_MESH_SYNC_RATE
1560         int "maximum synchronous transfer rate (MB/s) (0 = async)"
1561         depends on SCSI_MESH
1562         default "5"
1563         help
1564           On Power Macintoshes (and clones) where the MESH SCSI bus adaptor
1565           drives a bus which is entirely internal to the machine (such as the
1566           7500, 7600, 8500, etc.), the MESH is capable of synchronous
1567           operation at up to 10 MB/s. On machines where the SCSI bus
1568           controlled by the MESH can have external devices connected, it is
1569           usually rated at 5 MB/s. 5 is a safe value here unless you know the
1570           MESH SCSI bus is internal only; in that case you can say 10. Say 0
1571           to disable synchronous operation.
1572
1573 config SCSI_MESH_RESET_DELAY_MS
1574         int "initial bus reset delay (ms) (0 = no reset)"
1575         depends on SCSI_MESH
1576         default "4000"
1577
1578 config SCSI_MAC53C94
1579         tristate "53C94 (Power Mac external SCSI) support"
1580         depends on PPC32 && PPC_PMAC && SCSI
1581         help
1582           On Power Macintoshes (and clones) with two SCSI buses, the external
1583           SCSI bus is usually controlled by a 53C94 SCSI bus adaptor. Older
1584           machines which only have one SCSI bus, such as the 7200, also use
1585           the 53C94. Say Y to include support for the 53C94.
1586
1587           To compile this driver as a module, choose M here: the
1588           module will be called mac53c94.
1589
1590 source "drivers/scsi/arm/Kconfig"
1591
1592 config JAZZ_ESP
1593         bool "MIPS JAZZ FAS216 SCSI support"
1594         depends on MACH_JAZZ && SCSI
1595         help
1596           This is the driver for the onboard SCSI host adapter of MIPS Magnum
1597           4000, Acer PICA, Olivetti M700-10 and a few other identical OEM
1598           systems.
1599
1600 config A3000_SCSI
1601         tristate "A3000 WD33C93A support"
1602         depends on AMIGA && SCSI
1603         help
1604           If you have an Amiga 3000 and have SCSI devices connected to the
1605           built-in SCSI controller, say Y. Otherwise, say N.
1606
1607           To compile this driver as a module, choose M here: the
1608           module will be called wd33c93.
1609
1610 config A2091_SCSI
1611         tristate "A2091/A590 WD33C93A support"
1612         depends on ZORRO && SCSI
1613         help
1614           If you have a Commodore A2091 SCSI controller, say Y. Otherwise,
1615           say N.
1616
1617           To compile this driver as a module, choose M here: the
1618           module will be called wd33c93.
1619
1620 config GVP11_SCSI
1621         tristate "GVP Series II WD33C93A support"
1622         depends on ZORRO && SCSI
1623         ---help---
1624           If you have a Great Valley Products Series II SCSI controller,
1625           answer Y. Also say Y if you have a later model of GVP SCSI
1626           controller (such as the GVP A4008 or a Combo board). Otherwise,
1627           answer N. This driver does NOT work for the T-Rex series of
1628           accelerators from TekMagic and GVP-M.
1629
1630           To compile this driver as a module, choose M here: the
1631           module will be called gvp11.
1632
1633 config CYBERSTORM_SCSI
1634         tristate "CyberStorm SCSI support"
1635         depends on ZORRO && SCSI
1636         help
1637           If you have an Amiga with an original (MkI) Phase5 Cyberstorm
1638           accelerator board and the optional Cyberstorm SCSI controller,
1639           answer Y. Otherwise, say N.
1640
1641 config CYBERSTORMII_SCSI
1642         tristate "CyberStorm Mk II SCSI support"
1643         depends on ZORRO && SCSI
1644         help
1645           If you have an Amiga with a Phase5 Cyberstorm MkII accelerator board
1646           and the optional Cyberstorm SCSI controller, say Y. Otherwise,
1647           answer N.
1648
1649 config BLZ2060_SCSI
1650         tristate "Blizzard 2060 SCSI support"
1651         depends on ZORRO && SCSI
1652         help
1653           If you have an Amiga with a Phase5 Blizzard 2060 accelerator board
1654           and want to use the onboard SCSI controller, say Y. Otherwise,
1655           answer N.
1656
1657 config BLZ1230_SCSI
1658         tristate "Blizzard 1230IV/1260 SCSI support"
1659         depends on ZORRO && SCSI
1660         help
1661           If you have an Amiga 1200 with a Phase5 Blizzard 1230IV or Blizzard
1662           1260 accelerator, and the optional SCSI module, say Y. Otherwise,
1663           say N.
1664
1665 config FASTLANE_SCSI
1666         tristate "Fastlane SCSI support"
1667         depends on ZORRO && SCSI
1668         help
1669           If you have the Phase5 Fastlane Z3 SCSI controller, or plan to use
1670           one in the near future, say Y to this question. Otherwise, say N.
1671
1672 config SCSI_AMIGA7XX
1673         bool "Amiga NCR53c710 SCSI support (EXPERIMENTAL)"
1674         depends on AMIGA && SCSI && EXPERIMENTAL && BROKEN
1675         help
1676           Support for various NCR53c710-based SCSI controllers on the Amiga.
1677           This includes:
1678             - the builtin SCSI controller on the Amiga 4000T,
1679             - the Amiga 4091 Zorro III SCSI-2 controller,
1680             - the MacroSystem Development's WarpEngine Amiga SCSI-2 controller
1681               (info at
1682               <http://www.lysator.liu.se/amiga/ar/guide/ar310.guide?FEATURE5>),
1683             - the SCSI controller on the Phase5 Blizzard PowerUP 603e+
1684               accelerator card for the Amiga 1200,
1685             - the SCSI controller on the GVP Turbo 040/060 accelerator.
1686           Note that all of the above SCSI controllers, except for the builtin
1687           SCSI controller on the Amiga 4000T, reside on the Zorro expansion
1688           bus, so you also have to enable Zorro bus support if you want to use
1689           them.
1690
1691 config OKTAGON_SCSI
1692         tristate "BSC Oktagon SCSI support (EXPERIMENTAL)"
1693         depends on ZORRO && SCSI && EXPERIMENTAL
1694         help
1695           If you have the BSC Oktagon SCSI disk controller for the Amiga, say
1696           Y to this question.  If you're in doubt about whether you have one,
1697           see the picture at
1698           <http://amiga.resource.cx/exp/search.pl?product=oktagon>.
1699
1700 config ATARI_SCSI
1701         tristate "Atari native SCSI support"
1702         depends on ATARI && SCSI && BROKEN
1703         select SCSI_SPI_ATTRS
1704         ---help---
1705           If you have an Atari with built-in NCR5380 SCSI controller (TT,
1706           Falcon, ...) say Y to get it supported. Of course also, if you have
1707           a compatible SCSI controller (e.g. for Medusa).
1708
1709           To compile this driver as a module, choose M here: the
1710           module will be called atari_scsi.
1711
1712           This driver supports both styles of NCR integration into the
1713           system: the TT style (separate DMA), and the Falcon style (via
1714           ST-DMA, replacing ACSI).  It does NOT support other schemes, like
1715           in the Hades (without DMA).
1716
1717 config ATARI_SCSI_TOSHIBA_DELAY
1718         bool "Long delays for Toshiba CD-ROMs"
1719         depends on ATARI_SCSI
1720         help
1721           This option increases the delay after a SCSI arbitration to
1722           accommodate some flaky Toshiba CD-ROM drives. Say Y if you intend to
1723           use a Toshiba CD-ROM drive; otherwise, the option is not needed and
1724           would impact performance a bit, so say N.
1725
1726 config ATARI_SCSI_RESET_BOOT
1727         bool "Reset SCSI-devices at boottime"
1728         depends on ATARI_SCSI
1729         help
1730           Reset the devices on your Atari whenever it boots.  This makes the
1731           boot process fractionally longer but may assist recovery from errors
1732           that leave the devices with SCSI operations partway completed.
1733
1734 config TT_DMA_EMUL
1735         bool "Hades SCSI DMA emulator"
1736         depends on ATARI_SCSI && HADES
1737         help
1738           This option enables code which emulates the TT SCSI DMA chip on the
1739           Hades. This increases the SCSI transfer rates at least ten times
1740           compared to PIO transfers.
1741
1742 config MAC_SCSI
1743         bool "Macintosh NCR5380 SCSI"
1744         depends on MAC && SCSI=y
1745         select SCSI_SPI_ATTRS
1746         help
1747           This is the NCR 5380 SCSI controller included on most of the 68030
1748           based Macintoshes.  If you have one of these say Y and read the
1749           SCSI-HOWTO, available from
1750           <http://www.tldp.org/docs.html#howto>.
1751
1752 config SCSI_MAC_ESP
1753         tristate "Macintosh NCR53c9[46] SCSI"
1754         depends on MAC && SCSI
1755         help
1756           This is the NCR 53c9x SCSI controller found on most of the 68040
1757           based Macintoshes.  If you have one of these say Y and read the
1758           SCSI-HOWTO, available from
1759           <http://www.tldp.org/docs.html#howto>.
1760
1761           To compile this driver as a module, choose M here: the
1762           module will be called mac_esp.
1763
1764 config MVME147_SCSI
1765         bool "WD33C93 SCSI driver for MVME147"
1766         depends on MVME147 && SCSI=y
1767         select SCSI_SPI_ATTRS
1768         help
1769           Support for the on-board SCSI controller on the Motorola MVME147
1770           single-board computer.
1771
1772 config MVME16x_SCSI
1773         bool "NCR53C710 SCSI driver for MVME16x"
1774         depends on MVME16x && SCSI && BROKEN
1775         select SCSI_SPI_ATTRS
1776         help
1777           The Motorola MVME162, 166, 167, 172 and 177 boards use the NCR53C710
1778           SCSI controller chip.  Almost everyone using one of these boards
1779           will want to say Y to this question.
1780
1781 config BVME6000_SCSI
1782         bool "NCR53C710 SCSI driver for BVME6000"
1783         depends on BVME6000 && SCSI && BROKEN
1784         select SCSI_SPI_ATTRS
1785         help
1786           The BVME4000 and BVME6000 boards from BVM Ltd use the NCR53C710
1787           SCSI controller chip.  Almost everyone using one of these boards
1788           will want to say Y to this question.
1789
1790 config SCSI_NCR53C7xx_FAST
1791         bool "allow FAST-SCSI [10MHz]"
1792         depends on SCSI_AMIGA7XX || MVME16x_SCSI || BVME6000_SCSI
1793         help
1794           This will enable 10MHz FAST-SCSI transfers with your host
1795           adapter. Some systems have problems with that speed, so it's safest
1796           to say N here.
1797
1798 config SUN3_SCSI
1799         tristate "Sun3 NCR5380 SCSI"
1800         depends on SUN3 && SCSI && BROKEN
1801         select SCSI_SPI_ATTRS
1802         help
1803           This option will enable support for the OBIO (onboard io) NCR5380
1804           SCSI controller found in the Sun 3/50 and 3/60, as well as for
1805           "Sun3" type VME scsi controllers also based on the NCR5380.
1806           General Linux information on the Sun 3 series (now discontinued)
1807           is at <http://www.angelfire.com/ca2/tech68k/sun3.html>.
1808
1809 config SUN3X_ESP
1810         bool "Sun3x ESP SCSI"
1811         depends on SUN3X && SCSI=y
1812         help
1813           The ESP was an on-board SCSI controller used on Sun 3/80
1814           machines.  Say Y here to compile in support for it.
1815
1816 config SCSI_SUNESP
1817         tristate "Sparc ESP Scsi Driver"
1818         depends on SBUS && SCSI
1819         help
1820           This is the driver for the Sun ESP SCSI host adapter. The ESP
1821           chipset is present in most SPARC SBUS-based computers.
1822
1823           To compile this driver as a module, choose M here: the
1824           module will be called esp.
1825
1826 #      bool 'Cyberstorm Mk III SCSI support (EXPERIMENTAL)' CONFIG_CYBERSTORMIII_SCSI
1827
1828 config ZFCP
1829         tristate "FCP host bus adapter driver for IBM eServer zSeries"
1830         depends on S390 && QDIO && SCSI
1831         select SCSI_FC_ATTRS
1832         help
1833           If you want to access SCSI devices attached to your IBM eServer
1834           zSeries by means of Fibre Channel interfaces say Y.
1835           For details please refer to the documentation provided by IBM at
1836           <http://oss.software.ibm.com/developerworks/opensource/linux390>
1837
1838           This driver is also available as a module. This module will be
1839           called zfcp. If you want to compile it as a module, say M here
1840           and read <file:Documentation/modules.txt>.
1841
1842 endmenu
1843
1844 source "drivers/scsi/pcmcia/Kconfig"
1845
1846 endmenu