docs: Make it clear that ovs-openflowd is an alternative to ovs-vswitchd.
[sliver-openvswitch.git] / vswitchd / ovs-vswitchd.8.in
1 .\" -*- nroff -*-
2 .de IQ
3 .  br
4 .  ns
5 .  IP "\\$1"
6 ..
7 .TH ovs\-vswitchd 8 "June 2009" "Open vSwitch" "Open vSwitch Manual"
8 .\" This program's name:
9 .ds PN ovs\-vswitchd
10 .\" SSL peer program's name:
11 .ds SN ovs\-controller
12 .
13 .SH NAME
14 ovs\-vswitchd \- Open vSwitch daemon
15 .
16 .SH SYNOPSIS
17 .B ovs\-vswitchd
18 \fIdatabase\fR
19 .
20 .SH DESCRIPTION
21 A daemon that manages and controls any number of Open vSwitch switches 
22 on the local machine.
23 .PP
24 The mandatory \fIdatabase\fR argument normally takes the form
25 \fBunix:\fIfile\fR, where \fIfile\fR is the name of a Unix domain
26 socket on which \fBovsdb\-server\fR is listening.  However, all of the
27 following forms are accepted:
28 .so ovsdb/remote-active.man
29 .so ovsdb/remote-passive.man
30 .PP
31 \fBovs\-vswitchd\fR retrieves its configuration from \fIdatabase\fR at
32 startup.  It sets up Open vSwitch datapaths and then operates
33 switching across each bridge described in its configuration files.  As
34 the database changes, \fBovs\-vswitchd\fR automatically updates its
35 configuration to match.
36 .PP
37 Upon receipt of a SIGHUP signal, \fBovs\-vswitchd\fR reopens its log
38 file, if one was specified on the command line.
39 .PP
40 \fBovs\-vswitchd\fR switches may be configured with any of the following 
41 features:
42 .
43 .IP \(bu
44 L2 switching with MAC learning.
45 .
46 .IP \(bu
47 NIC bonding with automatic fail-over and source MAC-based TX load
48 balancing ("SLB").
49 .
50 .IP \(bu
51 802.1Q VLAN support.
52 .
53 .IP \(bu
54 Port mirroring, with optional VLAN tagging.
55 .
56 .IP \(bu
57 NetFlow v5 flow logging.
58 .
59 .IP \(bu
60 sFlow(R) monitoring.
61 .
62 .IP \(bu
63 Connectivity to an external OpenFlow controller, such as NOX.
64 .
65 .PP
66 Only a single instance of \fBovs\-vswitchd\fR is intended to run at a time.
67 A single \fBovs\-vswitchd\fR can manage any number of switch instances, up
68 to the maximum number of supported Open vSwitch datapaths.
69 .PP
70 \fBovs\-vswitchd\fR provides all the features of \fBovs-openflowd\fR,
71 and more.  Do not run both daemons at the same time.
72 .PP
73 \fBovs\-vswitchd\fR does all the necessary management of Open vSwitch datapaths
74 itself.  Thus, external tools, such \fBovs\-dpctl\fR(8), are not needed for
75 managing datapaths in conjunction with \fBovs\-vswitchd\fR, and their use
76 to modify datapaths when \fBovs\-vswitchd\fR is running can interfere with
77 its operation.  (\fBovs\-dpctl\fR may still be useful for diagnostics.)
78 .PP
79 An Open vSwitch datapath kernel module must be loaded for \fBovs\-vswitchd\fR
80 to be useful.  Please refer to the \fBINSTALL.Linux\fR file included in the
81 Open vSwitch distribution for instructions on how to build and load
82 the Open vSwitch kernel module.
83 .PP
84 .SH OPTIONS
85 .IP "\fB\-\-mlockall\fR"
86 Causes \fBovs\-vswitchd\fR to call the \fBmlockall()\fR function, to
87 attempt to lock all of its process memory into physical RAM,
88 preventing the kernel from paging any of its memory to disk.  This
89 helps to avoid networking interruptions due to system memory pressure.
90 .IP
91 Some systems do not support \fBmlockall()\fR at all, and other systems
92 only allow privileged users, such as the superuser, to use it.
93 \fBovs\-vswitchd\fR emits a log message if \fBmlockall()\fR is
94 unavailable or unsuccessful.
95 .
96 .IP "\fB\-\-fake\-proc\-net\fR"
97 Causes \fBovs\-vswitchd\fR to simulate some files in \fB/proc/net/vlan\fR
98 and \fB/proc/net/bonding\fR that some legacy software expects to
99 exist.  This option should only be used if such legacy software is
100 actually in use.  It requires the \fBbrcompat_mod.ko\fR kernel module
101 to be loaded.
102 .IP
103 On non-Linux hosts, this option is accepted but has no effect.
104 .
105 .so lib/daemon.man
106 .SS "Public Key Infrastructure Options"
107 .so lib/ssl.man
108 .so lib/ssl-bootstrap.man
109 .so lib/vlog.man
110 .so lib/common.man
111 .so lib/leak-checker.man
112 .
113 .SH "RUNTIME MANAGEMENT COMMANDS"
114 \fBovs\-appctl\fR(8) can send commands to a running
115 \fBovs\-vswitchd\fR process.  The currently supported commands are
116 described below.  The command descriptions assume an understanding of
117 how to configure Open vSwitch.
118 .SS "GENERAL COMMANDS"
119 .IP "\fBexit\fR"
120 Causes \fBovs\-vswitchd\fR to gracefully terminate.
121 .SS "BRIDGE COMMANDS"
122 These commands manage bridges.
123 .IP "\fBfdb/show\fR \fIbridge\fR"
124 Lists each MAC address/VLAN pair learned by the specified \fIbridge\fR,
125 along with the port on which it was learned and the age of the entry,
126 in seconds.
127 .IP "\fBbridge/reconnect\fR [\fIbridge\fR]"
128 Makes \fIbridge\fR drop all of its OpenFlow controller connections and
129 reconnect.  If \fIbridge\fR is not specified, then all bridges drop
130 their controller connections and reconnect.
131 .IP
132 This command might be useful for debugging OpenFlow controller issues.
133 .
134 .IP "\fBbridge/dump\-flows\fR \fIbridge\fR"
135 Lists all flows in \fIbridge\fR, including those normally hidden to
136 commands such as \fBovs\-ofctl dump\-flows\fR.  Flows set up by mechanisms
137 such as in-band control and fail-open are hidden from the controller
138 since it is not allowed to modify or override them.
139 .SS "BOND COMMANDS"
140 These commands manage bonded ports on an Open vSwitch's bridges.  To
141 understand some of these commands, it is important to understand a
142 detail of the bonding implementation called ``MAC hashing.''  Instead
143 of directly assigning Ethernet source addresses to slaves, the bonding
144 implementation computes a function that maps an 48-bit Ethernet source
145 addresses into an 8-bit value (a ``MAC hash'' value).  All of the
146 Ethernet addresses that map to a single 8-bit value are then assigned
147 to a single slave.
148 .IP "\fBbond/list\fR"
149 Lists all of the bonds, and their slaves, on each bridge.
150 .
151 .IP "\fBbond/show\fR \fIport\fR"
152 Lists all of the bond-specific information about the given bonded
153 \fIport\fR: updelay, downdelay, time until the next rebalance.  Also
154 lists information about each slave: whether it is enabled or disabled,
155 the time to completion of an updelay or downdelay if one is in
156 progress, whether it is the active slave, the MAC hashes assigned to
157 the slave, and the MAC learning table entries that hash to each MAC.
158 .IP "\fBbond/migrate\fR \fIport\fR \fIhash\fR \fIslave\fR"
159 Assigns a given MAC hash to a new slave.  \fIport\fR specifies the
160 bond port, \fIhash\fR either the MAC hash to be migrated (as a decimal
161 number between 0 and 255) or an Ethernet address to be hashed, and
162 \fIslave\fR the new slave to be assigned.
163 .IP
164 The reassignment is not permanent: rebalancing or fail-over will
165 cause the MAC hash to be shifted to a new slave in the usual
166 manner.
167 .IP
168 A MAC hash cannot be migrated to a disabled slave.
169 .IP "\fBbond/set\-active\-slave\fR \fIport\fR \fIslave\fR"
170 Sets \fIslave\fR as the active slave on \fIport\fR.  \fIslave\fR must
171 currently be enabled.
172 .IP
173 The setting is not permanent: a new active slave will be selected
174 if \fIslave\fR becomes disabled.
175 .IP "\fBbond/enable\-slave\fR \fIport\fR \fIslave\fR"
176 .IQ "\fBbond/disable\-slave\fR \fIport\fR \fIslave\fR"
177 Enables (or disables) \fIslave\fR on the given bond \fIport\fR, skipping any
178 updelay (or downdelay).
179 .IP
180 This setting is not permanent: it persists only until the carrier
181 status of \fIslave\fR changes.
182 .IP "\fBbond/hash\fR \fImac\fR"
183 Returns the hash value which would be used for \fImac\fR.
184 .
185 .so lib/vlog-unixctl.man
186 .SH "SEE ALSO"
187 .BR ovs\-appctl (8),
188 .BR ovs\-brcompatd (8),
189 .BR ovsdb\-server (1),
190 \fBINSTALL.Linux\fR in the Open vSwitch distribution.